Related papers: Spatiotemporal Flexible Sparse Reconstruction for …
Cardiac cine magnetic resonance imaging (MRI) is one of the important means to assess cardiac functions and vascular abnormalities. Mitigating artifacts arising during image reconstruction and accelerating cardiac cine MRI acquisition to…
Cone-beam computed tomography (CBCT) is a critical 3D imaging technology in the medical field, while the high radiation exposure required for high-quality imaging raises significant concerns, particularly for vulnerable populations.…
Reducing the radiation dose in computed tomography (CT) is important to mitigate radiation-induced risks. One option is to employ a well-trained model to compensate for incomplete information and map sparse-view measurements to the CT…
Multi-echo magnetic resonance (MR) images are acquired by changing the echo times (for T2 weighted) or relaxation times (for T1 weighted) of scans. The resulting (multi-echo) images are usually used for quantitative MR imaging. Acquiring MR…
Three-dimensional (3D) medical image enhancement, including denoising and super-resolution, is critical for clinical diagnosis in CT, PET, and MRI. Although diffusion models have shown remarkable success in 2D medical imaging, scaling them…
Spectral imaging enables spatially-resolved identification of materials in remote sensing, biomedicine, and astronomy. However, acquisition times require balancing spectral and spatial resolution with signal-to-noise. Hyperspectral imaging…
Diffusion MRI (dMRI) is sensitive to microstructural barriers, yet most existing methods either assume impermeable boundaries or estimate voxel-level parameters without recovering explicit interfaces. We present Spinverse, a…
Objective. Imaging dynamic object with high temporal resolution is challenging in magnetic resonance imaging (MRI). Partial separable (PS) model was proposed to improve the imaging quality by reducing the degrees of freedom of the inverse…
In Magnetic Resonance Imaging (MRI), image acquisitions are often undersampled in the measurement domain to accelerate the scanning process, at the expense of image quality. However, image quality is a crucial factor that influences the…
Wireless capsule endoscopy (WCE) is a non-invasive method for visualizing the gastrointestinal (GI) tract, crucial for diagnosing GI tract diseases. However, interpreting WCE results can be time-consuming and tiring. Existing studies have…
Wireless Capsule Endoscopy (WCE) presented in 2001 as one of the key approaches to observe the entire gastrointestinal (GI) tract, generally the small bowels. It has been used to detect diseases in the gastrointestinal tract. Endoscopic…
Magnetic resonance imaging (MRI) is widely employed for diagnostic tests in neurology. However, the utility of MRI is largely limited by its long acquisition time. Acquiring fewer k-space data in a sparse manner is a potential solution to…
Most existing MRI reconstruction methods perform tar-geted reconstruction of the entire MR image without tak-ing specific tissue regions into consideration. This may fail to emphasize the reconstruction accuracy on im-portant tissues for…
This paper presents an adaptive and intelligent sparse model for digital image sampling and recovery. In the proposed sampler, we adaptively determine the number of required samples for retrieving image based on space-frequency-gradient…
Fast Magnetic Resonance Imaging (MRI) is highly in demand for many clinical applications in order to reduce the scanning cost and improve the patient experience. This can also potentially increase the image quality by reducing the motion…
Magnetic Resonance Imaging (MRI) plays a crucial role in brain disease diagnosis, but it is not always feasible for certain patients due to physical or clinical constraints. Recent studies attempt to synthesize MRI from Computed Tomography…
We proposed a novel approach to coherent imaging of dynamic samples. The inter-frame similarity of the sample's local structures is found to be a powerful constraint in phasing a sequence of diffraction patterns. We devised a new image…
Sparse-view Computed Tomography (CT) is an emerging protocol designed to reduce X-ray dose radiation in medical imaging. Traditional Filtered Back Projection algorithm reconstructions suffer from severe artifacts due to sparse data. In…
We present Deep Compression Autoencoder (DC-AE), a new family of autoencoder models for accelerating high-resolution diffusion models. Existing autoencoder models have demonstrated impressive results at a moderate spatial compression ratio…
Purpose, To develop a high scanning efficiency, motion corrected imaging strategy for free-breathing pulmonary MRI by combining a motion compensation reconstruction with a UTE acquisition, called iMoCo UTE. Methods, An optimized golden…