English
Related papers

Related papers: Internal Calibration of the PandaX-II Detector wit…

200 papers

Radon gas emanating from materials is of interest in environmental science and also a major concern in rare event non-accelerator particle physics experiments such as dark matter and double beta decay searches, where it is a major source of…

Radon emanation was projected to account for $>50$% of the electron recoil background in the WIMP region of interest for the LUX-ZEPLIN (LZ) experiment. To mitigate the amount of radon inside the detector volume, materials with inherently…

Instrumentation and Detectors · Physics 2022-11-23 N. I. Chott , R. W. Schnee

Radioactive radon atoms originating from the long-lived primordial $^{238}\mathrm{U}$ and $^{232}\mathrm{Th}$ decay chains are constantly emanated from the surfaces of most materials. The radon atoms and their radioactive daughter isotopes…

Instrumentation and Detectors · Physics 2024-01-30 D. Wiebe , S. Lindemann , M. Schumann

An online cryogenic distillation system for the removal of krypton and radon from xenon was designed and constructed for PandaX-4T, a highly sensitive dark matter detection experiment. The krypton content in a commercial xenon product is…

Instrumentation and Detectors · Physics 2021-08-11 Xiangyi Cui , Zhou Wang , Yonglin Ju , Xiuli Wang , Huaxuan Liu , Wenbo Ma , Jianglai Liu , Li Zhao , Xiangdong Ji , Shuaijie Li , Rui Yan , Haidong Sha , Peiyao Huang

New particles beyond the standard model of particle physics, such as axions, can be effectively searched through their interactions with electrons. We use the large liquid xenon detector PandaX-4T to search for novel electronic recoil…

In this paper, we describe the XENON100 data analyses used to assess the target-intrinsic background sources radon ($^{222}$Rn), thoron ($^{220}$Rn) and krypton ($^{85}$Kr). We detail the event selections of high-energy alpha particles and…

Instrumentation and Methods for Astrophysics · Physics 2018-03-06 XENON Collaboration , E. Aprile , J. Aalbers , F. Agostini , M. Alfonsi , F. D. Amaro , M. Anthony , F. Arneodo , P. Barrow , L. Baudis , B. Bauermeister , M. L. Benabderrahmane , T. Berger , P. A. Breur , A. Brown , E. Brown , S. Bruenner , G. Bruno , R. Budnik , L. Bütikofer , J. Calvén , J. M. R. Cardoso , M. Cervantes , D. Cichon , D. Coderre , A. P. Colijn , J. Conrad , J. P. Cussonneau , M. P. Decowski , P. de Perio , P. Di Gangi , A. Di Giovanni , S. Diglio , G. Eurin , J. Fei , A. D. Ferella , A. Fieguth , W. Fulgione , A. Gallo Rosso , M. Galloway , F. Gao , M. Garbini , C. Geis , L. W. Goetzke , Z. Greene , C. Grignon , C. Hasterok , E. Hogenbirk , R. Itay , B. Kaminsky , S. Kazama , G. Kessler , A. Kish , H. Landsman , R. F. Lang , D. Lellouch , L. Levinson , Q. Lin , S. Lindemann , M. Lindner , F. Lombardi , J. A. M. Lopes , A. Manfredini , I. Maris , T. Marrodán Undagoitia , J. Masbou , F. V. Massoli , D. Masson , D. Mayani , M. Messina , K. Micheneau , A. Molinario , K. Morå , M. Murra , J. Naganoma , K. Ni , U. Oberlack , P. Pakarha , B. Pelssers , R. Persiani , F. Piastra , J. Pienaar , M. -C. Piro , V. Pizzella , G. Plante , N. Priel , D. Ramírez García , L. Rauch , S. Reichard , C. Reuter , A. Rizzo , N. Rupp , J. M. F. dos Santos , G. Sartorelli , M. Scheibelhut , S. Schindler , J. Schreiner , M. Schumann , L. Scotto Lavina , M. Selvi , P. Shagin , M. Silva , H. Simgen , M. v. Sivers , A. Stein , D. Thers , A. Tiseni , G. Trinchero , C. Tunnell , M. Vargas , H. Wang , Z. Wang , M. Weber , Y. Wei , C. Weinheimer , J. Wulf , J. Ye , Y. Zhang

The continuous emanation of radon due to trace amounts of uranium and thorium in detector materials introduces radon to the active detection volume of low-background rare event search detectors. $^{222}$Rn produces a particularly…

Instrumentation and Detectors · Physics 2021-06-08 M. Arthurs , D. Q. Huang , C. Amarasinghe , E. Miller , W. Lorenzon

The LZ dark matter detector, like many other rare-event searches, will suffer from backgrounds due to the radioactive decay of radon daughters. In order to achieve its science goals, the concentration of radon within the xenon should not…

Instrumentation and Detectors · Physics 2018-01-17 E. H. Miller , J. Busenitz , T. K. Edberg , C. Ghag , C. Hall , R. Leonard , K. Lesko , X. Liu , Yue Meng , A. Piepke , R. W. Schnee

To precisely measure radon concentrations in purified air supplied to the Super-Kamiokande detector as a buffer gas, we have developed a highly sensitive radon detector with an intrinsic background as low as 0.33$\pm$0.07 mBq/m$^{3}$. In…

Instrumentation and Detectors · Physics 2017-04-25 Y. Nakano , H. Sekiya , S. Tasaka , Y. Takeuchi , R. A. Wendell , M. Matsubara , M. Nakahata

A reliable and consistently reproducible technique to fabricate $^{222}$Rn-loaded radioactive sources ($\sim$0.5-1 kBq just after fabrication) based on liquid scintillator (LS), with negligible amounts of LS quencher contaminants, was…

Instrumentation and Detectors · Physics 2017-11-07 David Bravo-Berguño , Lino Miramonti , Paolo Cavalcante , Vincenzo Roca , Steve Hardy , Robert Bruce Vogelaar

Transition Radiation (TR) plays an important role in particle identification in high-energy physics and its characteristics provide a feasible method of energy calibration in the energy range up to 10 TeV, which is of interest for dark…

Instrumentation and Methods for Astrophysics · Physics 2020-04-06 Bo Huang , Hongbang Liu , Xuefeng Huang , Ming Xu , Yongwei Dong , Xiaotong Wei , Xiwen Liu , Huanbo Feng , Qinhe Yang , Jianyu Gu , Shuai Chen , Xiaochuan Xie , Jin Zhang , Yongbo Huang , Enwei Liang

The radioactive daughters isotope of 222Rn are one of the highest risk contaminants in liquid xenon detectors aiming for a small signal rate. The noble gas is permanently emanated from the detector surfaces and mixed with the xenon target.…

Instrumentation and Detectors · Physics 2018-03-14 Natascha Rupp

Radon-induced backgrounds, particularly from $^{222}$Rn and its beta-emitting progeny, present a critical challenge for next-generation liquid xenon (LXe) detectors aimed at probing dark matter down to the neutrino fog. To address this, we…

Instrumentation and Detectors · Physics 2025-11-06 Ryuta Miyata , Koki Fujikawa , Rina Harata , Yoshitaka Itow , Shingo Kazama , Masatoshi Kobayashi

The radiative electron capture (REC) into the K shell of bare Xe ions colliding with a hydrogen gas target has been investigated. In this study, the degree of linear polarization of the K-REC radiation was measured and compared with…

The radioactive noble gas radon can be a serious background source in the underground particle physics experiments studying processes that deposit energy comparable to its decay products. Low energy solar neutrino measurements at…

Instrumentation and Detectors · Physics 2020-10-12 Y. Nakano , T. Hokama , M. Matsubara , M. Miwa , M. Nakahata , T. Nakamura , H. Sekiya , Y. Takeuchi , S. Tasaka , R. A. Wendell

In order to solve the continuous large cooling power supply problem (20 kW) for the radon-removal cryogenic distillation system, which operates at high liquid ffow rate of 856 kg/h (5 LPM) for the dark matter detector PandaX-xT of the…

We report the search results of light dark matter through its interactions with shell electrons and nuclei, using the commissioning data from the PandaX-4T liquid xenon detector. Low energy events are selected to have an ionization-only…

High Energy Physics - Experiment · Physics 2023-08-29 PandaX Collaboration

Rotational and vibrational energy relaxation (RER and VER) of N$_2$O embedded in xenon and SF$_6$ environments ranging from the gas phase to the liquid, including the supercritical regime, is studied at a molecular level. Calibrated…

Chemical Physics · Physics 2024-10-25 Kai Töpfer , Shyamsunder Erramilli , Lawrence D. Ziegler , Markus Meuwly

PandaX-4T experiment is a deep-underground dark matter direct search experiment that employs a dual-phase time projection chamber with a sensitive volume containing 3.7 tonne of liquid xenon. The detector of PandaX-4T is capable of…