English
Related papers

Related papers: 200 mm Sensor Development Using Bonded Wafers

200 papers

A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$\mu$m. To solidify this concept, the…

Instrumentation and Detectors · Physics 2021-08-18 ALICE ITS project , : , G. Aglieri Rinella , M. Agnello , B. Alessandro , F. Agnese , R. S. Akram , J. Alme , E. Anderssen , D. Andreou , F. Antinori , N. Apadula , P. Atkinson , R. Baccomi , A. Badalà , A. Balbino , C. Bartels , R. Barthel , F. Baruffaldi , I. Belikov , S. Beole , P. Becht , A. Bhatti , M. Bhopal , N. Bianchi , M. B. Blidaru , G. Boca , J. Bok , G. Bonomi , M. Bonora , M. Borri , V. Borshchov , E. Botta , G. E. Bruno , M. Buckland , S. Bufalino , M. Cai , P. Camerini , P. Cariola , F. Catalano , C. Ceballos Sanchez , I. Chakaberia , M. Chartier , F. Colamaria , D. Colella , A. Collu , M. Concas , G. Contin , S. Costanza , P. Cui , A. Dainese , J. B. Dainton , L. De Cilladi , C. De Martin , G. De Robertis , W. Deng , A. Di Mauro , Y. Ding , M. Durkac , D. Elia , M. R. Ersdal , M. Faggin , F. Fan , A. Fantoni , P. Fecchio , A. Feliciello , G. Feofilov , A. Ferk , J. Ferencei , G. Fiorenza , A. N. Flores , E. Fragiacomo , D. Gajanana , A. Gal , C. Gao , C. Gargiulo , P. Gianotti , P. Giubilato , A. Grant , L. Greiner , A. Grelli , O. S. Groettvik , F. Grosa , C. Guo Hu , R. Hannigan , J. A. Hasenbichler , H. Helstrup , H. Hillemanns , C. Hills , P. Hindley , B. Hippolyte , B. Hofman , G. H. Hong , G. Huang , J. P. Iddon , H. Ilyas , M. A. Imhoff , A. Isakov , A. Jadlovska , S. Jadlovska , J. Jadlovsky , S. Jaelani , T. Johnson , A. Junique , P. Kalinak , A. Kalweit , M. Keil , Z. Khabanova , H. Khan , B. Kim , C. Kim , J. Kim , J. Kim , T. Kim , J. Klein , A. Kluge , C. Kobdaj , A. Kotliarov , I. Králik , F. Krizek , T. Kugathasan , C. Kuhn , P. G. Kuijer , S. Kushpil , M. J. Kweon , J. Y. Kwon , Y. Kwon , P. La Rocca , A. Lakrathok , R. Langoy , P. Larionov , E. Laudi , T. Lazareva , R. Lea , R. C. Lemmon , X. L. Li , J. Lien , B. Lim , S. H. Lim , S. Lindsay , A. Liu , J. Liu , J. Liu , M. Lunardon , G. Luparello , M. Lupi , M. Mager , A. Maire , Q. W. Malik , G. Mandaglio , V. Manzari , Y. Mao , G. V. Margagliotti , C. Markert , D. Marras , P. Martinengo , S. Masciocchi , M. Masera , A. Masoni , A. Mastroserio , P. F. T. Matuoka , G. Mazza , F. Mazzaschi , M. A. Mazzoni , F Morel , V. Muccifora , A. Mulliri , L. Musa , S. V. Nesbo , D. Nesterov , J. Norman , J. Park , R. N Patra , C. Pastore , H. Pei , X. Peng , S. Piano , C. Pinto , S. Pisano , S. Politano , E. Prakasa , F. Prino , M. Protsenko , M. Puccio , A. Rachevski , L. Ramello , F. Rami , I. Ravasenga , A. Rehman , F. Reidt , F. Riggi , K. Røed , D. Röhrich , F. Ronchetti , A. Rosano , M. J. Rossewij , A. Rossi , R. Rui , R. Russo , R. Sadikin , V. Sarritzu , J. Schambach , S. Senyukov , J. J. Seo , R. Shahoyan , S. Shaukat , S. Siddhanta , M. Sitta , R. J. M. Snellings , W. Snoeys , A. Songmoolnak , J. Sonneveld , F. Soramel , M. Suljic , S. Sumowidagdo , D. Sun , X. Sun , G. J. Tambave , G. Tersimonov , M. Tkacik , M. Toppi , A. Trifiró , S. Trogolo , V. Trubnikov , R. Turrisi , T. S. Tveter , I. Tymchuck , K. Ullaland , M. Urioni , G. L. Usai , N. Valle , L. V. R. van Doremalen , T. Vanat , J. W. Van Hoorne , M. Varga-Kofarago , A. Velure , D. Wang , Y. Wang , J. Wikne , J. R. Wright , R. Xu , P. Yang , Z. Yin , I. -K. Yoo , J. H. Yoon , S. Yuan , V. Zaccolo , E. Zhang , X. Zhang , V. Zherebchevskii , D. Zhou , J. Zhu , Y. Zhu , G. Zinovjev , N. Zurlo

We report on a compact, highly sensitive all-fiber accelerometer suitable for low frequency and low amplitude vibration sensing. The sensing elements in the device are two short segments of strongly coupled asymmetric multicore fiber (MCF)…

While the tracking detectors of the ATLAS and CMS experiments have shown excellent performance in Run 1 of LHC data taking, and are expected to continue to do so during LHC operation at design luminosity, both experiments will have to…

CMOS sensors were successfully implemented in the STAR tracker [1]. LHC experiments have shown that efficient b tagging, reconstruction of displaced vertices and identification of disappearing tracks are necessary. An improved vertex…

Instrumentation and Detectors · Physics 2021-05-21 Nicolas T. Fourches , Geraldine Hallais , Charles Renard

Excellent jet energy measurement is important at the International Linear Collider (ILC) because most of interesting physics processes decay into multi-jet final states. We employ a particle flow method to reconstruct particles, hence…

To fully exploit the increased luminosity of the HL-LHC, the CMS Inner Tracker is undergoing a major upgrade to withstand extreme radiation levels and data rates, while improving granularity and reducing material budget. The upgraded…

Instrumentation and Detectors · Physics 2025-06-12 Panagiotis Assiouras

As the start up date for LHC approaches, the detectors are readying for data taking. Here a review will be given on the construction phase with insights into the various difficulties encountered during the process. An overview will also be…

Instrumentation and Detectors · Physics 2010-08-17 Giacomo Sguazzoni

The central component of the CMS detector is the largest silicon tracker ever built. The precise alignment of this complex device is a formidable challenge, and only achievable with a significant extension of the technologies routinely used…

Instrumentation and Detectors · Physics 2014-08-22 CMS Collaboration

Silicon based micropattern detectors are essential elements of modern high energy physics experiments. Cost effectiveness and high radiation resistance are two important requirements for technologies to be used in inner tracking devices.…

Instrumentation and Detectors · Physics 2008-11-26 Marina Artuso

The ATLAS collaboration will replace its tracking detector with new all silicon pixel and strip systems. This will allow to cope with the higher radiation and occupancy levels expected after the 5-fold increase in the luminosity of the LHC…

The High Luminosity LHC (HL-LHC) will integrate 10 times more luminosity than the LHC, posing significant challenges for radiation tolerance and event pileup on detectors, especially for forward calorimetry, and hallmarks the issue for…

Instrumentation and Detectors · Physics 2018-07-01 Florian Pitters

The CMS pixel detector is the innermost component of the CMS tracker occupying the region around the centre of CMS, where the LHC beams are crossed, between 4.3 cm and 30 cm in radius and 46.5 cm along the beam axis. It operates in a…

Instrumentation and Detectors · Physics 2019-08-13 Viktor Veszpremi

Recent advancements in soft robots, human-machine interfaces, and wearable electronics have led to an increased demand for high-performance soft tactile sensors. Tomographic tactile sensor based on resistive coupling is a novel contact…

Human-Computer Interaction · Computer Science 2024-06-04 Shunsuke Yoshimoto , Koji Sakamoto , Rina Takeda , Akio Yamamoto

In view of the high luminosity phase of the LHC (HL-LHC) to start operation around 2026, a major upgrade of the tracker system for the ATLAS experiment is in preparation. The expected neutron equivalent fluence of up to 2.4 * 1e16 1 MeV…

Instrumentation and Detectors · Physics 2018-02-14 Julien-Christopher Beyer , Alessandro La Rosa , Anna Macchiolo , Natascha Savic , Reem Taibah

The barrel region of the CMS pixel detector will be equipped with ``n-in-n'' type silicon sensors. They are processed on DOFZ material, use the moderated p-spray technique and feature a bias grid. The latter leads to a small fraction of the…

Detectors proposed for the International Linear Collider (ILC) incorporate a tungsten sampling calorimeter (`BeamCal') intended to reconstruct showers of electrons, positrons and photons that emerge from the interaction point of the…

In view of the LHC upgrade phases towards the High Luminosity LHC (HL-LHC), the ATLAS experiment plans to upgrade the Inner Detector with an all-silicon system. The n-on-p silicon technology is a promising candidate to achieve a large area…

With the successful construction and operation of a highly granular hadron calorimeter system, featuring approx. 22000 individually read out SiPM-on-tile channels, the CALICE collaboration has set the next milestone in proving the…

Instrumentation and Detectors · Physics 2022-11-09 Daniel Heuchel

The physics aims at the proposed future CLIC high-energy linear $e^+ e^-$ collider pose challenging demands on the performance of the detector system. In particular the vertex and tracking detectors have to combine precision measurements…

Instrumentation and Detectors · Physics 2019-09-04 Mathieu Benoit

For operation at the High Luminosity Large Hadron Collider (LHC), the ATLAS experiment is building a new all-silicon inner tracker (ITk). The production and testing of thousands of silicon pixel and strip modules is required to cover the…

Instrumentation and Detectors · Physics 2022-03-23 D. Hohov , A. Lounis , A. Falou , E. - L. Gkougkousis , A. Bassalat