Related papers: Cepstral Analysis for Baseline-Insensitive Absorpt…
High-precision line intensities are of great value in various applications, such as greenhouse gas metrology, planetary atmospheric analysis, and trace gas detection. Here we report simultaneous measurements of cavity-enhanced absorption…
X-ray emission spectroscopy is a well-established technique used to study continuum lowering in dense plasmas. It relies on accurate atomic physics models to robustly reproduce high-resolution emission spectra, and depends on our ability to…
High-precision time-interval measurement is a fundamental technique in many advanced applications, including time and distance metrology, particle physics, and ultra-precision machining. However, many of these applications are confined by…
We demonstrate Doppler-free saturated absorption spectroscopy of cold molecular radicals formed by laser ablation inside a cryogenic buffer gas cell. By lowering the temperature, congested regions of the spectrum can be simplified, and by…
We demonstrate a new method of x-ray absorption spectroscopy (XAS) that is bulk sensitive, like traditional fluorescence yield measurements, but is not affected by self-absorption or saturation effects. This measure of XAS is achieved by…
Intracavity absorption spectroscopy (ICAS) is a well-established technique for detecting weak absorption signals with ultrahigh sensitivity. Here, we extend this concept to magnetometry using nitrogen-vacancy (NV) centers in diamond. We…
A variety of on-orbit imaging and spectroscopic observations are used to characterize the Charge Transfer Efficiency (CTE) of the Charge-Coupled Device (CCD) of the Space Telescope Imaging Spectrograph (STIS) aboard the Hubble Space…
Atomic Force Microscopy - Infrared (AFM-IR) spectroscopy allows spectroscopic studies in the mid-infrared spectral region with a spatial resolution better than 50 nm. We show that the high spatial resolution can be used to perform…
Differential optical absorption spectroscopy (DOAS) is a powerful tool for detecting and quantifying trace gases in atmospheric chemistry \cite{Platt_Stutz08}. DOAS spectra consist of a linear combination of complex multi-peak multi-scale…
With the decreasing sizes of integrated-circuit components, the semiconductor industry is in growing need of high-throughput strain mapping techniques that offer high precision and spatial resolution, with desired industry goals of…
The NIO1 experiment hosts a flexible RF H- ion source, developed by INFN-LNL and Consorzio RFX to improve the present concepts for the production and acceleration of negative ions. The source is also used to benchmark the instrumentation…
We present a new technique using a frequency comb laser and optical cavities for performing ultrafast transient absorption spectroscopy with improved sensitivity. Resonantly enhancing the probe pulses, we demonstrate a sensitivity of…
Weak transitions in the (2,0) overtone band of the HD molecule at $\lambda = 1.38 \, \mu$m were measured in saturated absorption using the technique of noise-immune cavity-enhanced optical heterodyne molecular spectroscopy. Narrow…
Time of flight backscattering spectrometry (ToF-BS) was successfully implemented in a helium ion microscope (HIM). Its integration introduces the ability to perform laterally resolved elemental analysis as well as elemental depth profiling…
The Heating Neutral Beam Injectors (HNBs) for ITER will have to deliver 16.7 MW beams of H/D particles at 1 MeV energy. The beams will be produced from H-/D- ions, generated by a radiofrequency plasma source coupled to an ion acceleration…
Compared to on-off keying (OOK), M-ary pulse amplitude modulation (M-PAM, M>2) is more spectrally efficient. However, to detect M-PAM signals reliably, the requirement of accurate channel state information is more stringent. Previously, for…
All observations by the aperture photometer (PHT-P) and the far-infrared (FIR) camera section (PHT-C) of ISOPHOT included reference measurements against stable internal fine calibration sources (FCS) to correct for temporal drifts in…
The design and characterization of a new laser-desorption molecular beam source, tailored for use in x-ray-free-electron-laser and ultrashort-pulse-laser imaging experiments, is presented. It consists of a single mechanical unit containing…
While mid-infrared radiation can be used to identify and quantify numerous chemical species, contemporary broadband mid-IR spectroscopic systems are often hindered by large footprints, moving parts and high power consumption. In this work,…
We present a novel approach to calculate molecular IR spectra based on semiclassical molecular dynamics. The main advance from a previous semiclassical method [M. Micciarelli, R. Conte, J. Suarez, M. Ceotto J. Chem. Phys. 149, 064115…