Related papers: Measuring the cophasing state of a segmented mirro…
Future Extremely Large Telescopes will adopt segmented primary mirrors with several hundreds of segments. Cophasing of the segments together is essential to reach high wavefront quality. The phasing sensor must be able to maintain very high…
Segmented aperture telescopes require an alignment procedure with successive steps from coarse alignment to monitoring process in order to provide very high optical quality images for stringent science operations such as exoplanet imaging.…
We present the first on-sky segmented primary mirror closed-loop piston control using a Zernike wavefront sensor (ZWFS) installed on the Keck II telescope. Segment co-phasing errors are a primary contributor to contrast limits on Keck and…
The next generation of large ground- and space-based optical telescopes will have segmented primary mirrors. Co-phasing the segments requires a sensitive wavefront sensor capable of measuring phase discontinuities. The Zernike wavefront…
We extend our previous demonstration of the first on-sky primary mirror segment closed-loop control on Keck using a vector-Zernike wavefront sensor (vZWFS), which improved the Strehl ratio on the NIRC2 science camera by up to 10 percentage…
In astronomy and microscopy, distortions in the wavefront affect the dynamic range of a high contrast imaging system. These aberrations are either imposed by a turbulent medium such as the atmosphere, by static or thermal aberrations in the…
Direct imaging of Earth-like exoplanets requires high contrast imaging capability and high angular resolution. Primary mirror segmentation is a key technological solution for large-aperture telescopes because it opens the path toward…
Co-phase and co-focus detection is one of the key technologies for large-aperture segmented mirror telescopes. In this paper, a new edge sensor based on fringes of equal thickness is developed, which can detect each segment's relative…
We present an enhanced version of the Zernike wavefront sensor, that simultaneously measures phase and amplitude aberrations. The 'vector-Zernike' wavefront sensor consists of a patterned liquid-crystal mask, which imposes $\pm \pi/2$ phase…
The Zernike wavefront sensor (ZWFS) stands out as one of the most sensitive optical systems for measuring the phase of an incoming wavefront, reaching photon efficiencies close to the fundamental limit. This quality, combined with the fact…
The maintenance of primary mirror segment co-phasing is a critical aspect to the operation of segmented telescopes. However, speckle-based measurements of the phasing of the Keck primary have estimated semi-static surface aberrations of…
Capturing high resolution imagery of the Earth's surface often calls for a telescope of considerable size, even from Low Earth Orbits (LEO). A large aperture often requires large and expensive platforms. For instance, achieving a resolution…
Continuous wavefront sensing benefits space observatories in on-orbit optical performance maintenance. To measure the phase of a wavefront, phase retrieval is an attractive technique as it uses multiple point spread function (PSF) images…
Advanced wavefront sensors (WFS) are essential for enabling new science cases for telescopes that utilize adaptive optics (AO) systems. While complex field WFS -- those that estimate the electric field phase and amplitude through…
The large apertures of the upcoming generation of Giant Segmented Mirror Telescopes will enable unprecedented angular resolutions that scale as $\propto$ $\lambda$/D and higher sensitivities that scale as $D^4$ for point sources corrected…
Phase imaging techniques extract the optical path-length information of a scene, whereas wavefront sensors provide the shape of an optical wavefront. Since these two applications have different technical requirements, they have developed…
A multi-level tunable reflection array wide-angle beam scanning method is proposed to address the limited bandwidth and small scanning angle issues of current terahertz beam scanning technology. In this method, a focusing lens and its array…
Future high-contrast imagers on ground-based extremely large telescopes will have to deal with the segmentation of the primary mirrors. Residual phase errors coming from the phase steps at the edges of the segments will have to be minimized…
To directly image Earth-like planets, contrast levels of 10^-8 - 10^-10 are required. The next generation of instruments will need wavefront control below the nanometer level to achieve these goals. The Zernike wavefront sensor (ZWFS) is a…
Future space telescopes with coronagraph instruments will use a wavefront sensor (WFS) to measure and correct for phase errors and stabilize the stellar intensity in high-contrast images. The HabEx and LUVOIR mission concepts baseline a…