We present the first on-sky segmented primary mirror closed-loop piston control using a Zernike wavefront sensor (ZWFS) installed on the Keck II telescope. Segment co-phasing errors are a primary contributor to contrast limits on Keck and will be necessary to correct for the next generation of space missions and ground-based extremely large telescopes (ELTs), which will all have segmented primary mirrors. The goal of the ZWFS installed on Keck is to monitor and correct primary mirror co-phasing errors in parallel with science observations. The ZWFS is ideal for measuring phase discontinuities such as segment co-phasing errors and is one of the most sensitive WFS, but has limited dynamic range. The vector-ZWFS at Keck works on the adaptive optics (AO) corrected wavefront and consists of a metasurface focal plane mask which imposes two different phase shifts on the core of the point spread function (PSF) to two orthogonal light polarizations, producing two pupil images. This design extends the dynamic range compared with the scalar ZWFS. The primary mirror segment pistons were controlled in closed-loop using the ZWFS, improving the Strehl ratio on the NIRC2 science camera by up to 10 percentage points. We analyze the performance of the closed-loop tests, the impact on NIRC2 science data, and discuss the ZWFS measurements.
Cite
@article{arxiv.2404.08728,
title = {Keck Primary Mirror Closed-Loop Segment Control using a Vector-Zernike Wavefront Sensor},
author = {Maissa Salama and Charlotte Guthery and Vincent Chambouleyron and Rebecca Jensen-Clem and J. Kent Wallace and Jacques-Robert Delorme and Mitchell Troy and Tobias Wenger and Daniel Echeverri and Luke Finnerty and Nemanja Jovanovic and Joshua Liberman and Ronald A. Lopez and Dimitri Mawet and Evan C. Morris and Maaike van Kooten and Jason J. Wang and Peter Wizinowich and Yinzi Xin and Jerry Xuan},
journal= {arXiv preprint arXiv:2404.08728},
year = {2024}
}
Comments
Accepted for publication in the Astrophysical Journal (ApJ). 17 pages, 16 figures