English
Related papers

Related papers: SiPM proton irradiation for application in cosmic …

200 papers

Prototype scintilator+WLS strips with SiPM readout for a muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon…

Instrumentation and Detectors · Physics 2016-04-15 Dmitri Denisov , Valery Evdokimov , Strahinja Lukić

Number-resolving single photon detectors are essential for the implementation of numerous innovative quantum information schemes. While several number-discriminating techniques have been previously presented, the Silicon Photo-Multiplier…

Quantum Physics · Physics 2015-05-30 L. Dovrat , M. Bakstein , D. Istrati , H. S. Eisenberg

In this paper I want to review the current status of development of multi-pixel silicon-based avalanche photo-diodes operated in Geiger mode, also known as Silicon Photomultipliers (SiPM). Particular emphasis is given to the application of…

Instrumentation and Detectors · Physics 2015-05-30 Erika Garutti

Complementary metal-oxide-semiconductor (CMOS) sensors are a competitive choice for future X-ray astronomy missions. Typically, CMOS sensors on space astronomical telescopes are exposed to a high dose of irradiation. We investigate the…

Instrumentation and Methods for Astrophysics · Physics 2023-12-05 Mingjun Liu , Zhixing Ling , Qinyu Wu , Chen Zhang , Jiaqiang Liu , Zhenlong Zhang , Weimin Yuan , Shuang-Nan Zhang

Silicon photomultipliers (SiPMs) are semiconductor-based light-sensors offering a high gain, a mechanically and optically robust design and high photon detection efficiency. Due to these characteristics, they started to replace conventional…

Instrumentation and Detectors · Physics 2018-06-27 T. Bretz , R. Engel , T. Hebbeker , J. Kemp , L. Middendorf , C. Peters , J. Schumacher , R. Smida , D. Veberic

The KLOE electromagnetic calorimeter is expected to be reused in the Near Detector complex of the DUNE experiment at Fermilab. The possible substitution of traditional Photomultiplier Tubes (PMTs) with Silicon Photomultipliers (SiPMs) in…

Instrumentation and Detectors · Physics 2024-06-19 F. Alemanno , P. Bernardini , A. Corvaglia , G. De Matteis , L. Martina , A. Miccoli , M. Panareo , M. P. Panetta , C. Pinto , A. Surdo

This report shows the design and the performance of a large area Silicon Photomultiplier (SiPM) module developed detection of fluorescent light emitted from a 10 cm scale volume. The module was optimized for the planned ACME III electron…

Instrumentation and Detectors · Physics 2022-11-09 A. Hiramoto , T. Masuda , D. G. Ang , C. Meisenhelder , C. Panda , N. Sasao , S. Uetake , X. Wu , D. Demille , J. M. Doyle , G. Gabrielse , K. Yoshimura

Next generation multi-ton scale noble liquid experiments have the unique opportunity to discover dark matter particles at the TeV scale, reaching the sensitivity of 10^-48 cm2 in the WIMP nucleon scattering cross-section. A prerequisite…

Instrumentation and Detectors · Physics 2016-01-07 S. Catalanotti , A. G. Cocco , G. Covone , M. D Incecco , G. Fiorillo , G. Korga , B. Rossi , S. Walker

Prototype scintilator+WLS strips with SiPM readout for muon system at future colliders were tested for light yield, time resolution and position resolution. Depending on the configuration, light yield of up to 36 photoelectrons per muon per…

Instrumentation and Detectors · Physics 2015-10-13 Dmitri Denisov , Valery Evdokimov , Strahinja Lukić

The gain of silicon photomultipliers (SiPMs) increases with bias voltage and decreases with temperature. To operate SiPMs at stable gain, the bias voltage can be readjusted to compensate for temperature changes. We have tested this concept…

Instrumentation and Detectors · Physics 2019-05-22 G. Eigen , J. Cvach , J. Kvasnicka , I. Polak , A. Træet , J. Zalieckas

Silicon photomultipliers (SiPMs) are increasingly favored for detecting near-UV, visible, and infrared light in space due to their high sensitivity to single photons and compact design. While SiPMs offer several advantages over traditional…

Instrumentation and Methods for Astrophysics · Physics 2025-09-23 Shideh Davarpanah for the NUSES Collaboration

The Sigma beam asymmetry for positive pion photoproduction on the proton has been measured over an angular range of 40-170 deg at photon energies from 0.8 to 1.5 GeV. The resulting data set includes 237 accurate points, 136 of these…

The combination of plastic scintillators with Silicon Photo-Multipliers (SiPMs) is widely used for detecting radiation in high-energy astrophysics, particle physics, neutrino physics, or medical physics. An example of application for this…

Instrumentation and Methods for Astrophysics · Physics 2025-02-14 Nicolas De Angelis , Franck Cadoux , Coralie Husi , Merlin Kole , Sławomir Mianowski

Large-area silicon photomultipliers (SiPMs) are desired in many applications where large surfaces have to be covered. For instance, a large area SiPM has been developed by Hamamatsu Photonics in collaboration with the University of Geneva,…

Instrumentation and Methods for Astrophysics · Physics 2023-02-08 Nicolas De Angelis , David Gascón , Sergio Gómez , Matthieu Heller , Teresa Montaruli , Andrii Nagai

Several types of Silicon Photomultipliers were exposed to short pulsed laser light (~ 30 ps FWHM) with its intensity varying from single photon to well above the number of microcells of the device. We observed a significant deviation of the…

Instrumentation and Detectors · Physics 2013-11-25 L. Gruber , S. E. Brunner , J. Marton , K. Suzuki

Following first large-scale applications in highly granular calorimeters and in neutrino detectors, Silicon Photomultipliers have seen a wide adoption in accelerator-based particle and nuclear physics experiments. Today, they are used for a…

Instrumentation and Detectors · Physics 2019-05-06 Frank Simon

The NEXT-White detector, a high-pressure gaseous xenon time projection chamber, demonstrated the excellence of this technology for future neutrinoless double beta decay searches using photomultiplier tubes (PMTs) to measure energy and…

High Energy Physics - Experiment · Physics 2024-08-19 T. Contreras , B. Palmeiro , H. Almazán , A. Para , G. Martínez-Lema , R. Guenette , C. Adams , V. Álvarez , B. Aparicio , A. I. Aranburu , L. Arazi , I. J. Arnquist , F. Auria-Luna , S. Ayet , C. D. R. Azevedo , K. Bailey , F. Ballester , M. del Barrio-Torregrosa , A. Bayo , J. M. Benlloch-Rodríguez , F. I. G. M. Borges , A. Brodolin , N. Byrnes , S. Cárcel , A. Castillo , S. Cebrián , E. Church , L. Cid , C. A. N. Conde , F. P. Cossío , E. Dey , G. Díaz , T. Dickel , C. Echevarria , M. Elorza , J. Escada , R. Esteve , R. Felkai , L. M. P. Fernandes , P. Ferrario , A. L. Ferreira , F. W. Foss , Z. Freixa , J. García-Barrena , J. J. Gómez-Cadenas , R. González , J. W. R. Grocott , J. Hauptman , C. A. O. Henriques , J. A. Hernando Morata , P. Herrero-Gómez , V. Herrero , C. Hervés Carrete , Y. Ifergan , B. J. P. Jones , F. Kellerer , L. Larizgoitia , A. Larumbe , P. Lebrun , F. Lopez , N. López-March , R. Madigan , R. D. P. Mano , A. P. Marques , J. Martín-Albo , M. Martínez-Vara , R. L. Miller , K. Mistry , J. Molina-Canteras , F. Monrabal , C. M. B. Monteiro , F. J. Mora , K. E. Navarro , P. Novella , A. Nuñez , D. R. Nygren , E. Oblak , J. Palacio , I. Parmaksiz , A. Pazos , J. Pelegrin , M. Pérez Maneiro , M. Querol , A. B. Redwine , J. Renner , I. Rivilla , C. Rogero , L. Rogers , B. Romeo , C. Romo-Luque , F. P. Santos , J. M. F. dos Santos , M. Seemann , I. Shomroni , P. A. O. C. Silva , A. Simón , S. R. Soleti , M. Sorel , J. Soto-Oton , J. M. R. Teixeira , S. Teruel-Pardo , J. F. Toledo , C. Tonnelé , J. Torrent , A. Trettin , A. Usón , P. R. G. Valle , J. F. C. A. Veloso , J. Waiton , A. Yubero-Navarro

Silicon detector technologies are often employed for high energy particle physics applications due to their excellent radiation hardness. Radiation damage in the form of bulk or substrate damage is dependent on the incident particle species…

Instrumentation and Detectors · Physics 2025-02-17 E. Liu , A. Chisholm , L. Gonella , A. Hunter

In low earth orbit, there are many cosmic rays composed primarily of high energy protons. These cosmic rays cause surface and bulk radiation effects, resulting in degradation of detector performance. Quantitative evaluation of radiation…

Eight PbWO4 crystals produced for the electromagnetic calorimeter of the CMS experiment at LHC have been irradiated in a 20 GeV/c proton beam up to fluences of 5.4 E13 p/cm2. The damage recovery in these crystals, stored in the dark at room…

Instrumentation and Detectors · Physics 2009-11-11 P. Lecomte , D. Luckey , F. Nessi-Tedaldi , F. Pauss