English
Related papers

Related papers: Simons Observatory Microwave SQUID Multiplexing Re…

200 papers

Superconducting microcalorimeters, such as superconducting transition-edge sensors and magnetic microcalorimeters, have emerged as state-of-the-art detectors for X-ray emission spectroscopy by combining near-unity quantum efficiency with…

Instrumentation and Detectors · Physics 2026-04-29 Jodok Zeuner , Constantin Schuster , Sebastian Kempf

The CMB-S4 experiment is developing next-generation ground-based microwave telescopes to observe the Cosmic Microwave Background with unprecedented sensitivity. This will require an order of magnitude increase in the 100 mK detector count,…

Kinetic inductance bolometer (KIB) technology is a candidate for passive sub-millimeter wave and terahertz imaging systems. Its benefits include scalability into large 2D arrays and operation with intermediate cryogenics in the temperature…

The latest generation of cosmic microwave background (CMB) telescopes is searching for the undetected faint signature of gravitational waves from inflation in the polarized signal of the CMB. To achieve the unprecedented levels of…

Instrumentation and Methods for Astrophysics · Physics 2013-01-08 Darcy Barron , Matt Atlas , Brian Keating , Ron Quillin , Nathan Stebor , Brandon Wilson

Simultaneous readout of large-scale cryogenic detector arrays relies on multiplexing schemes such as the FDM (Frequency-Division Multiplexing) with microwave SQUID multiplexers and highly customized readout electronics. In traditional…

Instrumentation and Detectors · Physics 2025-12-08 Timo Muscheid , Daniel Crovo , Robert Gartmann , Eduardo Gerlein , Oliver Sander , Sebastian Kempf , Luis E. Ardila-Perez

Improved measurements of $B$-modes in the cosmic microwave background can be obtained through accurate calibration of the orientation of detector antennas as projected onto the sky. Miscalibration of the detector polarization angle leads to…

The Simons Observatory Large Aperture Telescope Receiver (SO LATR) is a next generation Cosmic Microwave Background camera equipped with > 60, 000 detectors operating at 100 mK. Maintaining these detectors at the correct temperatures and…

Instrumentation and Methods for Astrophysics · Physics 2026-04-27 John Orlowski-Scherer , Anna Kofman , Tanay Bhandarkar , Mark Devlin , Saianeesh K. Haridas , Jeff Iuliano , Alex Manduca , Robert J. Thornton

Scanning Superconducting QUantum Interference Device (SQUID) microscopy is a powerful tool for imaging local magnetic properties of materials and devices, but it requires a low-vibration cryogenic environment, traditionally achieved by…

Superconductivity · Physics 2019-07-04 Logan Bishop-Van Horn , Zheng Cui , John R. Kirtley , Kathryn A. Moler

Superconducting lithographed resonators have a broad range of current and potential applications in the multiplexed readout of cryogenic detectors. Here, we focus on LC bandpass filters with resonances in the 1-5 MHz range used in the…

Advanced ACTPol is an instrument upgrade for the six-meter Atacama Cosmology Telescope (ACT) designed to measure the cosmic microwave background (CMB) temperature and polarization with arcminute-scale angular resolution. To achieve its…

The microwave SQUID multiplexer (umux) has enabled higher bandwidth or higher channel counts across a wide range of experiments in particle physics, astronomy, and spectroscopy. The large multiplexing factor coupled with recent commercial…

Solid-state quantum computers require classical electronics to control and readout individual qubits and to enable fast classical data processing [1-3]. Integrating both subsystems at deep cryogenic temperatures [4], where solid-state…

The POLARBEAR-2 CosmicMicrowave Background (CMB) experiment aims to observe B-mode polarization with high sensitivity to explore gravitational lensing of CMB and inflationary gravitational waves. POLARBEAR-2 is an upgraded experiment based…

We report on a scanned superconducting quantum interference device (SQUID) microscope operating in a cryogen-free cryostat, with the capability of up to forty RF connections with 20 GHz bandwidth to a device under test. The system utilizes…

Superconductivity · Physics 2025-09-10 Ian W. Haygood , Bochao Xu , John Biesecker , Michael L. Schneider

We describe the design of a cryogenic rotation stage (CRS) for use with the cryogenic half-wave plate (CHWP) polarization modulator on the POLARBEAR-2b and POLARBEAR-2c (PB2b/c) cosmic microwave background (CMB) experiments, the second and…

The scalability of most transition-edge sensor arrays is limited by the multiplexing technology which combines their signals over a reduced number of wires and amplifiers. In this Letter, we present and demonstrate a multiplexer design…

This work describes the design and implementation of optics for EXCLAIM, the EXperiment for Cryogenic Large-Aperture Intensity Mapping. EXCLAIM is a balloon-borne telescope that will measure integrated line emission from carbon monoxide…

‹ Prev 1 3 4 5 6 7 10 Next ›