Related papers: Performance recovery of long CsI(Tl) scintillator …
CALIFA is the high efficiency and energy resolution calorimeter for the R$^{3}$B experiment at FAIR, intended for detecting high energy charged particles and $\gamma$-rays in inverse kinematics direct reactions. It surrounds the reaction…
The R3B experiment at FAIR studies nuclear reactions using high-energy radioactive beams. One key detector in R3B is the CALIFA calorimeter consisting of 2544 CsI(Tl) scintillator crystals designed to detect light charged particles and…
This article describes the crystal selection and quality control utilized to develop and calibrate a high resolution array of CsI(TI) scintillator crystals for the detection of energetic charged particles. Alpha sources are used to test the…
We have measured scintillation properties of pure CsI crystals used in the shower calorimeter built for a precise determination of the pi+ -> pi0 e+ nu decay rate at the Paul Scherrer Institute (PSI). All 240 individual crystals painted…
The light output of the 324 CsI(Tl) scintillators of INDRA has been measured over a large range both in energy: 1 - 80 AMeV and in atomic number of incident ions: Z = 1 - 60. An analytical expression for the nonlinear total light response…
Sufficient energy resolution is the key issue for the calorimetry in particle and nuclear physics. The calorimeter of the A4 parity violation experiment at MAMI is a segmented calorimeter where the energy of an event is determined by…
We present here the Calar Alto Legacy Integral Field Area (CALIFA) survey, which has been designed to provide a first step in this direction.We summarize the survey goals and design, including sample selection and observational strategy.We…
We present the Calar Alto Legacy Integral Field Area survey (CALIFA). CALIFA's main aim is to obtain spatially resolved spectroscopic information for ~600 galaxies of all Hubble types in the Local Universe (0.005< z <0.03). The survey has…
Simulated calorimeter performance in the SiD detector is examined. The software calibration procedures are described, as well as the perfect pattern recognition PFA reconstruction. Performance of the SiD calorimeters is summarized with jet…
The Crystal Barrel is an electromagnetic calorimeter consisting of 1380 CsI(Tl) scintillators, and is currently installed at the CBELSA/TAPS experiment where it is used to detect decay products from photoproduction of mesons. The readout of…
Chromatic calorimetry (CCAL) analyses particle detection by utilizing scintillators with distinct emission wavelengths to measure the longitudinal energy deposition of particle showers in high-energy physics, improving particle…
Measurements of the degradation in performance of 30 cm long CsI(Tl) scintillation crystals exposed to 1 MeV photon doses of 2, 10, 35, 100 and 1000 Gy are presented. The light yield, light yield longitudinal non-uniformity, scintillation…
Detector efficiency determination is essential to correct the measured yields and extract reliable cross sections of particles emitted in nuclear reactions. We investigate the efficiencies for measuring the full energies of light charged…
In the reconstruction of physics events at future e$^+$e$^-$ colliders the calorimeter design has a crucial role in the overall detector performance. The reconstruction of events with many jets in their final state sets stringent…
Cryogenic detectors have a long history of success in the field of rare event searches. In particular scintillating calorimeters are very suitable detectors for this task since they provide particle discrimination: the simultaneous…
The scintillating properties of active materials used in high energy and particle physics experiments play an important role regarding the performances of both calorimeters and experiments. Two scintillator materials, a scintillating glass…
Searches for weakly interacting massive particles(WIMP) can be based on the dete ction of nuclear recoil energy in CsI(Tl) crystals. We demonstrate that low energy gamma rays down to few keV is detected with CsI(Tl) crystal detector. A…
A cryogenic detector system based on two 3.3 kg high-purity CsI crystals was developed and characterized at approximately 95 K. Each wedge-shaped crystal was coupled to dual-ended 3-inch photomultiplier tubes (PMTs) for scintillation…
We report on the design and performance of the electromagnetic calorimeter timing readout system (EMTiming) for the Collider Detector at Fermilab (CDF). The system will be used in searches for rare events with high energy photons to verify…
In a neutrinoless double-beta decay ($0\nu\beta\beta$) experiment, energy resolution is important to distinguish between $0\nu\beta\beta$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy…