Measurements of the degradation in performance of 30 cm long CsI(Tl) scintillation crystals exposed to 1 MeV photon doses of 2, 10, 35, 100 and 1000 Gy are presented. The light yield, light yield longitudinal non-uniformity, scintillation decay times, energy resolution and timing resolution of a set of spare crystals from the BABAR and Belle experiments are studied as a function of these doses. In addition, a model that describes the plateau observed in the light output loss as a function of dose in terms of increase in concentrations of absorption centres with irradiation is presented.
@article{arxiv.1608.07556,
title = {Radiation Hardness of 30 cm Long CsI(Tl) Crystals},
author = {Savino Longo and John Michael Roney},
journal= {arXiv preprint arXiv:1608.07556},
year = {2016}
}
Comments
This is an author-created, un-copyedited version of an article accepted for publication/published in Journal of Instrumentation. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The Version of Record is available online at http://dx.doi.org/10.1088/1748-0221/11/08/P08017