English
Related papers

Related papers: High-precision mass spectrometer for light ions

200 papers

We present precision Penning-trap mass measurements of neutron-rich calcium and potassium isotopes in the vicinity of neutron number N=32. Using the TITAN system the mass of $^{51}$K was measured for the first time, and the precision of the…

Masses adjacent to the classical waiting-point nuclide 130Cd have been measured by using the Penning- trap spectrometer ISOLTRAP at ISOLDE/CERN. We find a significant deviation of over 400 keV from earlier values evaluated by using nuclear…

The recent observation of single spins flips with a single proton in a Penning trap opens the way to measure the proton magnetic moment with high precision. Based on this success, which has been achieved with our apparatus at the University…

Penning trap mass measurements on neutron-deficient Cd isotopes (99-109)Cd have been performed with the ISOLTRAP mass spectrometer at ISOLDE/CERN, all with relative mass uncertainties below 3*10^8. A new mass evaluation has been performed.…

First on-line mass measurements were performed at the SHIPTRAP Penning trap mass spectrometer. The masses of 18 neutron-deficient isotopes in the terbium-to-thulium region produced in fusion-evaporation reactions were determined with…

We have realized a high-resolution time-of-flight mass spectrometer combined with a magneto-optical trap. The spectrometer enables excellent optical access to the trapped atomic cloud using specifically devised acceleration and deflection…

Masses of 56,57Fe, 53Co^m, 53,56Co, 55,56,57Ni, 57,58Cu, and 59,60Zn have been determined with the JYFLTRAP Penning trap mass spectrometer at IGISOL with a precision of dm/m \le 3 x 10^{-8}. The QEC values for 53Co, 55Ni, 56Ni, 57Cu, 58Cu,…

In this letter, we report a new mass for $^{11}$Li using the trapping experiment TITAN at TRIUMF's ISAC facility. This is by far the shortest-lived nuclide, $t_{1/2} = 8.8 \rm{ms}$, for which a mass measurement has ever been performed with…

If the mass excess of neutron-deficient nuclei and their neutron-rich mirror partners are both known, it can be shown that deviations of the Isobaric Mass Multiplet Equation (IMME) in the form of a cubic term can be probed. Such a cubic…

The two most recent and precise measurements of the charged kaon mass use X-rays from kaonic atoms and report uncertainties of 14 ppm and 22 ppm yet differ from each other by 122 ppm. We describe the possibility of an independent mass…

The proton, deuteron and triton masses can be determined relative to the electron mass via rovibrational spectroscopy of molecular hydrogen ions. This has to occur via comparison of the experimentally measured transition frequencies and the…

Atomic Physics · Physics 2025-05-13 Stephan Schiller , Jean-Philippe Karr

The absolute mass of $^{84}$Sr was determined using the phase-imaging ion-cyclotron-resonance technique with the JYFLTRAP double Penning trap mass spectrometer. A more precise value for the mass of $^{84}$Sr is essential for providing…

State-of-the-art optical clocks achieve fractional precisions of $10^{-18}$ and below using ensembles of atoms in optical lattices or individual ions in radio-frequency traps. Promising candidates for novel clocks are highly charged ions…

We have conceived, built and operated a 'half-open' cylindrical Penning trap for the confinement and laser spectroscopy of highly charged ions. This trap allows fluorescence detection employing a solid angle which is about one order of…

Atomic Physics · Physics 2015-06-18 David von Lindenfels , Manuel Vogel , Wolfgang Quint , Gerhard Birkl , Marco Wiesel

High-precision mass measurements of $^{63}$Cu, $^{64-66}$Zn, $^{65}$Ga, $^{65-67}$Ge, $^{67}$As, $^{78,81}$Br, $^{80}$Rb, and $^{79}$Sr were performed utilizing a multireflection time-of-flight mass spectrograph combined with the gas-filled…

The highest precision in direct mass measurements is obtained with Penning trap mass spectrometry. Most experiments use the interconversion of the magnetron and cyclotron motional modes of the stored ion due to excitation by external…

We have demonstrated that the ion current resulting from collisions between metastable krypton atoms in a magneto-optical trap can be used to precisely measure the trap loading rate. We measured both the ion current of the abundant isotope…

Positrons are accumulated within a Penning trap designed to make more precise measurements of the positron and electron magnetic moments. The retractable radioactive source used is weak enough to require no license for handling radioactive…

Instrumentation and Detectors · Physics 2023-11-14 S. Fogwell Hoogerheide , J. C. Dorr , E. Novitski , G. Gabrielse

We report on the first direct mass measurements of the $^{118,119}$Cd and $^{117-119}$In isotopes performed at the Ion Guide Isotope Separator On-Line facility using the JYFLTRAP double Penning trap mass spectrometer. The masses of…

Mass measurements with the ISOLTRAP mass spectrometer at CERN-ISOLDE improve mass uncertainties of neutron-deficient tin isotopes towards doubly-magic $^{100}$Sn. The mass uncertainty of $^{103}$Sn was reduced by a factor of 4, and the new…