We report an $\textit{in situ}$ mass measurement of approximately-$4.7{\text -}\mu$m-diameter, optically levitated microspheres with an electrostatic co-levitation technique. The mass of a trapped, charged microsphere is measured by holding…

Instrumentation and Detectors · Physics 2019-11-11 Charles P. Blakemore , Alexander D. Rider , Sandip Roy , Alexander Fieguth , Akio Kawasaki , Nadav Priel , Giorgio Gratta

The electron mass in atomic mass units has been determined with a relative uncertainty of $2.8\cdot 10^{-11}$, which represents a 13-fold improvement of the 2010 CODATA value. The underlying measurement principle combines a high-precision…

Atomic Physics · Physics 2016-04-18 Florian Köhler , Sven Sturm , Anke Kracke , Günter Werth , Wolfgang Quint , Klaus Blaum

The Canadian Penning Trap mass spectrometer (CPT) has conducted precision mass measurements of neutron-rich nuclides from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) of the Argonne Tandem Linac Accelerator System (ATLAS) facility…

Instrumentation and Detectors · Physics 2025-04-29 D. Ray , A. A. Valverde , M. Brodeur , F. Buchinger , J. A. Clark , B. Liu , G. E. Morgan , R. Orford , W. S. Porter , G. Savard , K. S. Sharma , X. L. Yan

The atomic mass difference of 163Ho and 163Dy has been directly measured with the Penning trap mass spectrometer SHIPTRAP applying the novel phase imaging ion cyclotron resonance technique. Our measurement has solved the long standing…

We report on the mass measurements of several neutron-rich $\mathrm{Rb}$ and $\mathrm{Sr}$ isotopes in the $A \approx 100$ region with the TITAN Penning-trap mass spectrometer. Using highly charged ions in the charge state $q=10+$, the…

The investigation of the absolute scale of the effective neutrino mass remains challenging due to the exclusively weak interaction of neutrinos with all known particles in the standard model of particle physics. Currently, the most precise…

We present Penning-trap mass measurements of neutron-rich 44,47-50K and 49,50Ca isotopes carried out at the TITAN facility at TRIUMF-ISAC. The 44K mass measurement was performed with a charge-bred 4+ ion utilizing the TITAN EBIT, and agrees…

High precision radio-frequency, microwave and infrared spectroscopic measurements of the antihydrogen molecular ion $\bar{H}_{2}^{-}$ ($\bar{p}\bar{p}e^{+}$) compared with its normal matter counterpart provide direct tests of the CPT…

Atomic Physics · Physics 2018-07-30 Edmund G. Myers

Recent exciting progress in the preparation and manipulation of the motional quantum states of a single trapped proton enabled the first direct detection of the particle's spin state. Based on this success the proton magnetic moment $\mu_p$…

We present an all-optical mass spectrometry technique to identify trapped ions. The new method uses laser-cooled ions to determine the mass of a cotrapped dark ion with a sub-dalton resolution within a few seconds. We apply the method to…

Atomic Physics · Physics 2021-01-13 M. Fan , C. A. Holliman , X. Shi , H. Zhang , M. W. Straus , X. Li , S. W. Buechele , A. M. Jayich

The absolute mass value of $^{168}$Yb has been directly determined with the JYFLTRAP Penning trap mass spectrometer at the Ion Guide Isotope Separator On-Line (IGISOL) facility. A more precise value of the mass of $^{168}$Yb is needed to…

Nuclear Experiment · Physics 2020-10-28 D. A. Nesterenko , R. P. de Groote , T. Eronen , Z. Ge , M. Hukkanen , A. Jokinen , A. Kankainen

The Texas A&M University Penning Trap facility is an upcoming ion trap that will be used to search for possible scalar currents in T=2 superallowed $\beta$-delayed proton decays, which, if found, would be an indication of physics beyond the…

A new procedure to prepare isomerically clean samples of ions with a mass resolving power of more than 100,000 has been developed at the JYFLTRAP tandem Penning trap system. The method utilises a dipolar rf-excitation of the ion motion with…

Nuclear Experiment · Physics 2008-11-26 T. Eronen , V. -V. Elomaa , U. Hager , J. Hakala , A. Jokinen , A. Kankainen , S. Rahaman , J. Rissanen , C. Weber , J. Aysto

A high-accuracy mass measurement of 7Li was performed with the Smiletrap Penning trap mass spectrometer via a cyclotron frequency comparison of Li3+ and H2+. A new atomic mass value of 7Li has been determined to be 7.016,003,425,6,(45)u…

Nuclear Experiment · Physics 2012-09-25 Sz. Nagy , T. Fritioff , M. Suhonen , R. Schuch , K. Blaum , M. Björkhage , I. Bergström

We propose the use of trapped ions for detection of millicharged dark matter. Millicharged particles will scatter off the ions, giving a signal either in individual events or in the overall heating rate of the ions. Ion traps have several…

High Energy Physics - Phenomenology · Physics 2021-08-12 Dmitry Budker , Peter W. Graham , Harikrishnan Ramani , Ferdinand Schmidt-Kaler , Christian Smorra , Stefan Ulmer

This review article describes the trapping of charged particles. The main principles of electromagnetic confinement of various species from elementary particles to heavy atoms are briefly described. The preparation and manipulation with…

Atomic Physics · Physics 2010-02-14 K. Blaum , Yu. N. Novikov , G. Werth

Neutron-rich $^{120-124}$In isotopes have been studied utilizing the double Penning trap mass spectrometer JYFLTRAP at the IGISOL facility. Using the phase-imaging ion-cyclotron-resonance technique, the isomeric states were resolved from…

High-precision mass measurements on neutron-rich zinc isotopes 71m,72-81Zn have been performed with the Penning trap mass spectrometer ISOLTRAP. For the first time the mass of 81Zn has been experimentally determined. This makes 80Zn the…

Ramsey's method of separated oscillatory fields is applied to the excitation of the cyclotron motion of short-lived ions in a Penning trap to improve the precision of their measured mass. The theoretical description of the extracted…