English
Related papers

Related papers: Beyond Fourier transform: super-resolving optical …

200 papers

Optical coherence tomography angiography (OCTA) is a non-invasive imaging modality that extends the functionality of OCT by extracting moving red blood cell signals from surrounding static biological tissues. OCTA has emerged as a valuable…

Image and Video Processing · Electrical Eng. & Systems 2023-05-04 Jinpeng Liao , Tianyu Zhang , Yilong Zhang , Chunhui Li , Zhihong Huang

Optical coherence tomography angiography (OCTA) is a non-invasive imaging technique widely used to study vascular structures and micro-circulation dynamics in the retina and choroid. OCTA has been widely used in clinics for diagnosing…

Image and Video Processing · Electrical Eng. & Systems 2025-08-26 Kejie Chen , Guanbing Gao , Xiaochun Yang , Wenbo Wang , Jing Na

Optical coherence tomography angiography (OCTA) is a novel non-invasive imaging modality for the visualisation of microvasculature in vivo that has encountered broad adoption in retinal research. OCTA potential in the assessment of…

Image and Video Processing · Electrical Eng. & Systems 2020-06-02 Ylenia Giarratano , Eleonora Bianchi , Calum Gray , Andrew Morris , Tom MacGillivray , Baljean Dhillon , Miguel O. Bernabeu

In this work, we propose to leverage a deep-learning (DL) based reconstruction framework for high quality Swept-Source Optical Coherence Tomography (SS-OCT) images, by incorporating wavelength ({\lambda}) space interferometric fringes.…

Image and Video Processing · Electrical Eng. & Systems 2024-10-08 Maryam Viqar , Erdem Sahin , Violeta Madjarova , Elena Stoykova , Keehoon Hong

At the present time Optical Coherence Tomography (OCT) is among the most commonly used non-invasive imaging methods for the acquisition of large volumetric scans of human retinal tissues and vasculature. To resolve decisive information from…

Computer Vision and Pattern Recognition · Computer Science 2021-11-02 D. Sitenko , B. Boll , C. Schnörr

We present the first demonstration of shot-noise limited supercontinuum-based spectral domain optical coherence tomography (SD-OCT) with axial resolution of 5.9 $\mu$m at a center wavelength of 1370 nm. Current supercontinuum-based SD-OCT…

Optical diffraction tomography (ODT) enables non-invasive information-rich 3D refractive index (RI) reconstruction of unimpaired transparent biological and technical samples, crucial in biomedical research, optical metrology, materials…

Optical coherence tomography (OCT) is being increasingly adopted as a label-free and non-invasive technique for biomedical applications such as cancer and ocular disease diagnosis. Diagnostic information for these tissues is manifest in…

In this paper, we consider subaperture-based approaches for the digital aberration correction (DAC) of optical coherence tomography (OCT) images. In particular, we introduce a mathematical framework for describing this class of approaches,…

We propose and experimentally demonstrate temporally low-coherent optical diffraction tomography (ODT) based on angle-scanning Mach-Zehnder interferometry. Using a digital micromirror device based on diffractive tilting, we successfully…

Optics · Physics 2018-07-17 KyeoReh Lee , Seungwoo Shin , Zahid Yaqoob , Peter T. C. So , YongKeun Park

Optical diffraction tomography (ODT) is a three-dimensional (3D) label-free imaging technique. The 3D refractive index distribution of a sample can be reconstructed from multiple two-dimensional optical field images via ODT. Herein, we…

Optics · Physics 2021-02-03 Chansuk Park , Kyeoreh Lee , Yoonseok Baek , Yongkeun Park

In recent years, there has been a growing interest in applying convolutional neural networks (CNNs) to low-level vision tasks such as denoising and super-resolution. Due to the coherent nature of the image formation process, optical…

Computer Vision and Pattern Recognition · Computer Science 2019-01-29 Ashkan Abbasi , Amirhassan Monadjemi , Leyuan Fang , Hossein Rabbani , Yi Zhang

Non-contact measurement of the refractive index and thickness of multilayer biological tissues is of great significance for biomedical applications and can greatly improve medical diagnosis and treatment. In this work, we introduce a…

Optics · Physics 2024-04-19 Yu-Lin Ku , Yao-Gen Shu

Optical coherence tomography (OCT) is a prevalent, interferometric, high-resolution imaging method with broad biomedical applications. Nonetheless, OCT images suffer from an artifact, called speckle which degrades the image quality. Digital…

Optical coherence tomography angiography (OCTA) is a new imaging modality to visualize retinal microvasculature and has been readily adopted in clinics. High-resolution OCT angiograms are important to qualitatively and quantitatively…

Image and Video Processing · Electrical Eng. & Systems 2023-05-11 Yuyan Ruan , Dawei Yang , Ziqi Tang , An Ran Ran , Carol Y. Cheung , Hao Chen

A new formulation of lateral imaging process of point-scanning optical coherence tomography (OCT) and a new differential contrast method designed by using this formulation are presented. The formulation is based on a mathematical sample…

Optical Coherence Tomography (OCT) provides high-resolution, 3D, and non-invasive visualization of retinal layers in vivo, serving as a critical tool for lesion localization and disease diagnosis. However, its widespread adoption is limited…

Optical Coherence Tomography (OCT) is the primary imaging modality for detecting pathological biomarkers associated to retinal diseases such as Age-Related Macular Degeneration. In practice, clinical diagnosis and treatment strategies are…

Computer Vision and Pattern Recognition · Computer Science 2019-07-17 Thomas Kurmann , Pablo Márquez-Neila , Siqing Yu , Marion Munk , Sebastian Wolf , Raphael Sznitman

We demonstrate a three-dimensional (3D) optical diffraction tomographic technique with optimal frequency combination (OFC-ODT) for the 3D quantitative phase imaging of unlabeled specimens. Three sets of through-focus intensity images are…

Optics · Physics 2018-03-06 Jiaji Li , Qian Chen Jiasong Sun , Jialin Zhang , Junyi Ding , Chao Zuo

Non-destructive testing (NDT) is crucial for ensuring product quality and safety across various industries. Conventional methods such as ultrasonic, terahertz, and X-ray imaging have limitations in terms of probe-contact requirement, depth…

‹ Prev 1 4 5 6 7 8 10 Next ›