Related papers: Wavelength and Refractive Indices from Interferome…
We design a spectrally resolved interferometer to measure the refractive index of transparent samples over a broad spectral range between 400 and 550 nm. The measuring device consists of a Michelson interferometer whose output is analysed…
In very intense electromagnetic fields, the vacuum refractive index is expected to be modified due to nonlinear quantum electrodynamics (QED) properties. Several experimental tests using high intensity lasers have been proposed to observe…
Determination of refractive index of micro-disks of a calcinated ($1100^\circ$C in air) photo-resist SZ2080$^\mathrm{TM}$ was carried out using transmission and reflection spectroscopy. Interference fringes at specific…
We present an update of the "refractive index of air" experiment commonly used in optics and undergraduate advanced labs. The refractive index of air is based on the average molecular polarizability, which we measured from the period of the…
Radiation pressure on a flat mirror submerged in a transparent liquid, depends not only on the refractive index n of the liquid, but also on the phase angle psi_0 of the Fresnel reflection coefficient of the mirror, which could be anywhere…
A novel method is proposed to measure the refractive indices (RIs) of the materials of different transparent solid state media. To exploit the advantage of non-contact measurement laser beam interferometry is used as an effective technique…
White light spectral interferometry is applied to measure the refractive index in absorbing liquids in the spectral range from 400 to 1000 nm. We analyze the influence of absorption on the visibility of interferometric fringes and,…
The refractive index of single microparticles is derived from precise measurement and rigorous modeling of the stiffness of a laser trap. We demonstrate the method for particles of four different materials with diameters from 1.6 to 5.2…
The detection of spatial or temporal variations in very thin samples has important applications in the biological sciences. For example, cellular membranes exhibit changes in lipid composition and order, which in turn modulate their…
Highly-resolved determination of refractive index is vital in fields ranging from biosensing through to laser range-finding. Laser speckle is known to be a sensitive probe of the properties of the light and the environment, but to date…
We use coherence theory to explain why it is necessary to modify the conventional setup of a Michelson interferometer to obtain Haidinger rings with an extended source of white light. The modification consists of introducing a glass slide…
In this work we present a refractive index sensor based on the leaky radiation of a microfiber. The 5.3um diameter microfiber is fabricated by drawing a commercial optical fiber. When the microfiber is immersed into a liquid with larger…
We report the first use of Michelson interferometry on the Keck I telescope for diffraction-limited imaging in the near infrared JHK and L bands. By using an aperture mask located close to the f/25 secondary, the 10 m Keck primary mirror…
We present 5-15 micron imaging spectroscopy of the reflection nebulae vdB 17 (NGC 1333), vdB 59 (NGC 2068), vdB 101, vdB 111, vdB 133 and vdB 135, obtained with the infrared camera and circular variable filter wheel on the Infrared Space…
A new system, consisting of a double channel Fabry Perot etalon and laser diodes emitting around 780 nm is described and proposed to be used for air refractive index measurements. The principle of this refractometer is based on frequency…
Refractive index is a fundamental optical property of powder and a key input to the measurement of the size distribution using light scattering and the measurement of the absorption and scattering coefficients using diffuse reflectance…
I have found experimentally that in vacuum (refractive index $n$ = 1.) the shift of interference fringe in Michelson interferometer is absent because of the absence of particles on the light path. The shift of interference fringe appears…
A refractive index sensor based on a semicircular bent fiber is presented. The interference occurs between the cladding mode excited in the bending region and the core mode. Both the theoretical and experimental results show that the…
We report experiments of light transmissivity at wavelengths: 532 and 400 nm, through an Au film with a wedge shape. Our results mimic the negative refraction reported by others for so-called left handed materials. A mimic of negative…
In this work the behavior of optical micro-ring resonators, especially when functioning as refractive index sensors, is studied in detail. Two configurations are considered, namely a linear waveguide coupled to a circular one and two linear…