Related papers: Constructing a control-ready model of EEG signal d…
This paper presents a model-based control architecture. Based on the Medical Cyber-physical Systems (MCPS) concept, we construct a safe and reliable automatic anesthesia control closed-loop system. The control architecture uses the…
This paper proposes an adaptive neuro-fuzzy framework to improve drug infusion rate in closed-loop control of anesthesia. The proposed controller provides a sub-optimal propofol administration rate as input to reach the desired bispectral…
The patient must be given an adequate amount of propofol for safe surgery since overcapacity and low capacity cause accidents. However, the sensitivity of propofol varies from patient to patient, making it very difficult to determine the…
This paper proposes a constrained control scheme for the control of the depth of hypnosis during induction phase in clinical anesthesia. In contrast with existing control schemes for propofol delivery, the proposed scheme guarantees…
In this paper, a multi-model predictive control approach is used to automate the co-administration of propofol and remifentanil from bispectral index measurement during general anesthesia. To handle the parameter uncertainties in the…
Objectives. Accurately predicting transitions to anesthetic drugs overdosage is a critical challenge in general anesthesia as it requires the identification of EEG indicators relevant for anticipating the evolution of the depth of…
We present a non-linear dynamical system for modelling the effect of drug infusions on the vital signs of patients admitted in Intensive Care Units (ICUs). More specifically we are interested in modelling the effect of a widely used…
Patients with epilepsy can manifest short, sub-clinical epileptic "bursts" in addition to full-blown clinical seizures. We believe the relationship between these two classes of events---something not previously studied…
Conscious state estimation is important in various medical settings, including sleep staging and anesthesia management, to ensure patient safety and optimize health outcomes. Traditional methods predominantly utilize electroencephalography…
We investigate several quantifiers of the electroencephalogram (EEG) signal with respect to their ability to indicate depth of anesthesia. For 17 patients anesthetized with Sevoflurane, three established measures (two spectral and one based…
Closed loop anesthesia delivery (CLAD) systems can help anesthesiologists efficiently achieve and maintain desired anesthetic depth over an extended period of time. A typical CLAD system would use an anesthetic marker, calculated from…
Reliable seizure detection from electroencephalography (EEG) time series is a high-priority clinical goal, yet the acquisition cost and scarcity of labeled EEG data limit the performance of machine learning methods. This challenge is…
The present study introduces an innovative approach to the synthesis of Electroencephalogram (EEG) signals by integrating diffusion models with reinforcement learning. This integration addresses key challenges associated with traditional…
Accurately predicting anesthetic effects is essential for target-controlled infusion systems. The traditional (PK-PD) models for Bispectral index (BIS) prediction require manual selection of model parameters, which can be challenging in…
Continuous electroencephalography (EEG) is routinely used in neurocritical care to monitor seizures and other harmful brain activity, including rhythmic and periodic patterns that are clinically significant. Although deep learning methods…
Electroencephalography (EEG) plays a significant role in the Brain Computer Interface (BCI) domain, due to its non-invasive nature, low cost, and ease of use, making it a highly desirable option for widespread adoption by the general…
Propofol, when administered for general anesthesia, induces oscillatory dynamic brain states that are thought to underlie the drug's pharmacological effects. Despite the elucidation of propofol's mechanisms of action at the molecular level,…
This work provides a formalized model-invariant safety system for closed-loop anesthesia that uses feedback from measured data for model falsification to reduce conservatism. The safety system maintains predicted propofol plasma…
Epileptic seizure prediction from electroencephalographic (EEG) recordings remains challenging due to strong inter-patient variability and the complex temporal structure of neural signals. This paper presents a patient-adaptive transformer…
This paper studies linear mathematical modeling of brain's cortical dynamics using electroencephalography (EEG) data in an experiment with continuous exogenous input. The EEG data were recorded while participants were seated with their…