Related papers: A Functional Form for Liquid Scintillator Pulse Sh…
Many modern digital analyzers offer the ability to record raw pulses from ionizing radiation detectors. We use this opportunity to investigate the effectiveness of Charge Comparison Method in Pulse Shape Discrimination of neutron and gamma…
It is very important to measure the plasma performances of fusion reactors such as fuel ion density, plasma temperature, fusion power, fast neutron energy, and neutron flux. Various diagnostic systems are needed to measure fast neutron…
This work reports on the performance of a novel neutron-sensitive scintillating detector fabricated using Fused-Deposition Modelling (FDM) additive manufacturing. FDM is a cost-effective 3D-printing method employing flexible plastic…
A first comparison has been made between the pulse-shape discrimination characteristics of a novel $^{4}$He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and…
The characteristics of the Solid-state Neutron Detector, under development for neutron-scattering measurements at the European Spallation Source, have been simulated with a Geant4-based computer code. The code models the interations of…
A novel algorithm for the discrimination of neutron and {\gamma}-ray with wavelet transform modulus maximum (WTMM) in an organic scintillation has been investigated. Voltage pulses arising from a BC501A organic liquid scintillation detector…
Scintillators capable of detecting both neutrons and gamma-rays have generated considerable interest. In particular, the use of such scintillators with silicon photomultipliers (SiPMs) enables low-power and compact-geometry applications.…
Pulse-shape analysis of the ionization signals from germanium gamma-ray spectrometers is a method for obtaining information that can characterize an event beyond just the total energy deposited in the crystal. However, as typically…
Various pulse shape discrimination methods have been used to solve the neutron-gamma discrimination problem. But most of them are limited to off-line calculation due to the computation amount and FPGA performance. In order to realize real…
In this manuscript we report on the scintillation properties and pulse shape discrimination (PSD) performance of new organic glass scintillator. Two cylindrical samples with dimensions of 2x2 inches were tested. Additionally, this two…
The proton light yield of organic scintillators has been measured extensively in recent years using fast waveform digitizers and large discrepancies exist in the values reported by different authors. In this letter, we address principles of…
The basic principles of detection of fast neutrons with liquid scintillator detectors are reviewed, together with a real example in the form of the Neutron Wall array. Two of the challenges in neutron detection, discrimination of neutrons…
Pulse shape discrimination with pure CsI scintillators is investigated as a method for separating energy deposits by energetic neutrons and photons at particle physics experiments. Using neutron data collected near the European XFEL XS1…
This work describes a class of liquid scintillators that contain mostly water (>50 wt. % of the entire composition) and can discriminate between interactions induced by neutrons and gamma rays. By balancing the interface interactions…
The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate…
One of the most promising approaches for the next generation of neutrino experiments is the realization of large hybrid Cherenkov/scintillation detectors made possible by recent innovations in photodetection technology and liquid…
A 3-D position sensitive neutron detector is being developed based on a plastic scintillator array. A double side SiPM readout is used to determine the depth of interaction (DOI) in each scintillator unit. In the preliminary test, the DOI…
Scintillation detector has lower energy resolution for Gamma-ray as compared to semiconductor detector, better spectra analysis method is essential to traditional method. A model for describing the response function of scintillation…
Fast electronic readout for high-channel density scintillator-based systems is needed for radiation tracking and imaging in a wide range of applications, including nuclear physics, nuclear security and nonproliferation. Programmable…
We report the performance and characterization of a custom-built hybrid detector consisting of BC501A liquid scintillator for fast neutrons and BC702 scintillator for thermal neutrons. The calibration and the resolution of the BC501A liquid…