English
Related papers

Related papers: ROI-Wise Material Decomposition in Spectral Photon…

200 papers

X-Ray Phase-Contrast Imaging (PCI) yields absorption, differential phase, and dark-field images. Computed Tomography (CT) of grating-based PCI can in principle provide high-resolution soft-tissue contrast. Recently, grating-based PCI took…

Model-based material decomposition is a statisticaliterative reconstruction framework where basis material densityimages are estimated directly from spectral CT data. This methoduses a physical model for polyenergetic x-ray transmission…

Medical Physics · Physics 2020-10-06 Matthew Tivnan , Wenying Wang , J. Webster Stayman

Recently, spectral CT has been drawing a lot of attention in a variety of clinical applications primarily due to its capability of providing quantitative information about material properties. The quantitative integrity of the reconstructed…

Medical Physics · Physics 2018-01-12 Shiyu Xu , Peter Prinsen , Jens Wiegert , Ravindra Manjeshwar

By acquiring two sets of tomographic measurements at distinct X-ray spectra, the dual-energy CT (DECT) enables quantitative material-specific imaging. However, the conventionally decomposed material basis images may encounter severe image…

This paper introduces an innovative imaging method using reconfigurable intelligent surfaces (RISs) by combining radar coincidence imaging (RCI) and computational imaging techniques. In the proposed framework, RISs simultaneously redirect…

Signal Processing · Electrical Eng. & Systems 2025-07-11 Kavian Zirak , Mohammadreza F. Imani

Computed tomography (CT) has been developed as a non-destructive technique for observing minute internal images of samples. It has been difficult to obtain photo-realistic (clean or clear) CT images due to various unwanted artifacts…

Quantum Physics · Physics 2023-09-12 Kyungtaek Jun

Objective: Quantitative technique based on In-line phase-contrast computed tomography with single scanning attracts more attention in application due to the flexibility of the implementation. However, the quantitative results usually suffer…

Medical Physics · Physics 2022-06-13 Suyu Liao , Shiwo Deng , Yining Zhu , Huitao Zhang , Peiping Zhu , Kai Zhang , Xing Zhao

Ultra-high resolution images are desirable in photon counting CT (PCCT), but resolution is physically limited by interactions such as charge sharing. Deep learning is a possible method for super-resolution (SR), but sourcing paired training…

Image and Video Processing · Electrical Eng. & Systems 2024-02-27 Christopher Wiedeman , Chuang Niu , Mengzhou Li , Bruno De Man , Jonathan S Maltz , Ge Wang

We tackle the challenge of efficiently reconstructing 3D scenes with high detail on objects of interest. Existing 3D Gaussian Splatting (3DGS) methods allocate resources uniformly across the scene, limiting fine detail to Regions Of…

Graphics · Computer Science 2025-10-20 Quoc-Anh Bui , Gilles Rougeron , Géraldine Morin , Simone Gasparini

Computed tomography (CT) involves a patient's exposure to ionizing radiation. To reduce the radiation dose, we can either lower the X-ray photon count or down-sample projection views. However, either of the ways often compromises image…

Image and Video Processing · Electrical Eng. & Systems 2023-10-12 Wenjun Xia , Yongyi Shi , Chuang Niu , Wenxiang Cong , Ge Wang

When it comes to computed tomography (CT), the possibility to reconstruct a small region-of-interest (ROI) using truncated projection data is particularly appealing due to its potential to lower radiation exposure and reduce the scanning…

Numerical Analysis · Mathematics 2016-10-04 Tatiana A. Bubba , Demetrio Labate , Gaetano Zanghirati , Silvia Bonettini

Purpose: To evaluate a proposed method to reconstruct CT numbers that accurately mimic conventional CT numbers from spectral CT data, as would have been produced by a conventional system without effects of beam hardening. Approach: We…

Medical Physics · Physics 2022-08-10 Fredrik Grönberg , Hans Bornefalk

Recent years have seen growing interest in exploiting dual- and multi-energy measurements in computed tomography (CT) in order to characterize material properties as well as object shape. Material characterization is performed by…

Computer Vision and Pattern Recognition · Computer Science 2015-09-30 Brian H. Tracey , Eric L. Miller

Modern tomography involves gathering projection data from multiple directions and feeding them into a software algorithm for tomographic reconstruction. We focus our study on image reconstruction from Radon data in the setting of…

Numerical Analysis · Mathematics 2014-12-19 Maria Angela Narduzzo

Quantum optimization for computed tomography (CT) reconstruction is constrained by the number of binary variables required for image representation, making direct whole-image quantum reconstruction difficult for large or structurally…

Quantum Physics · Physics 2026-05-29 Hyunju Lee , Jeonghwa Lee , Kyungtaek Jun

Background: Limited-angle (LA) dual-energy (DE) cone-beam CT (CBCT) is considered as a potential solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, its clinical implementations…

Multi-energy CT takes advantage of the non-linearly varying attenuation properties of elemental media with respect to energy, enabling more precise material identification than single-energy CT. The increased precision comes with the cost…

Medical Physics · Physics 2020-02-14 Jussi Toivanen , Alexander Meaney , Samuli Siltanen , Ville Kolehmainen

Computed tomography for region-of-interest (ROI) reconstruction has advantages of reducing X-ray radiation dose and using a small detector. However, standard analytic reconstruction methods suffer from severe cupping artifacts, and existing…

Computer Vision and Pattern Recognition · Computer Science 2019-05-28 Yoseob Han , Jong Chul Ye

Differential phase contrast interior tomography allows for reconstruction of a refractive index distribution over a region of interest (ROI) for visualization and analysis of internal structures inside a large biological specimen. In this…

Medical Physics · Physics 2015-05-30 Wenxiang Cong , Ge Wang

The sheer volume and size of histopathological images (e.g.,10^6 MPixel) underscores the need for faster and more accurate Regions-of-interest (ROI) detection algorithms. In this paper, we propose such an algorithm, which has four main…

Computer Vision and Pattern Recognition · Computer Science 2017-04-10 Li Sulimowicz , Ishfaq Ahmad