Related papers: T2-weighted Spine Imaging using a Single-Shot Turb…
Purpose: Bilateral Orthogonality Generative Acquisitions (BOGA) method, which was initially implemented for T_2^* contrast via gradient echo acquisitions, is adapted for TSE imaging at 7T using parallel transmission (pTx) system for…
Purpose: To demonstrate an ultrashort echo time magnetic resonance fingerprinting (UTE-MRF) method that can simultaneously quantify tissue relaxometries for muscle and bone in musculoskeletal systems and tissue components in brain and…
Purpose: To develop and validate a multi-parametric SAturation-recovery single-SHot Acquisition (mSASHA) cardiac T1 and T2 mapping technique with high accuracy and precision in a single breath-hold. Methods: The mSASHA acquisition consists…
In this work, we propose a realistic, physics-aware motion simulation procedure for T2*-weighted magnetic resonance imaging (MRI) to improve learning-based motion correction. As T2*-weighted MRI is highly sensitive to motion-related changes…
The technique of propagating spin wave spectroscopy is applied to a 20 nm thick Fe/MgO (001) film. The magnetic parameters extracted from the position of the resonance peaks are very close to those tabulated for bulk iron. From the…
This paper presents a large publicly available multi-center lumbar spine magnetic resonance imaging (MRI) dataset with reference segmentations of vertebrae, intervertebral discs (IVDs), and spinal canal. The dataset includes 447 sagittal T1…
Purpose: Magnetization transfer saturation (MTsat) mapping is commonly used to examine the macromolecular content of brain tissue. This study compared variable flip angle (VFA) T1 mapping against compressed sensing (cs)MP2RAGE T1 mapping…
Purpose: The purpose of this study is to demonstrate a method for Specific Absorption Rate (SAR) reduction for T2-FLAIR MRI sequences at 7T by predicting the required adiabatic pulse power and scaling the amplitude in a slice-wise fashion.…
Spin noise spectroscopy has become a widespread technique to extract information on spin dynamics in atomic and solid-state systems, in a potentially non-invasive way, through the optical probing of spin fluctuations. Here we experimentally…
We propose a novel compressed sensing technique to accelerate the magnetic resonance imaging (MRI) acquisition process. The method, coined spread spectrum MRI or simply s2MRI, consists of pre-modulating the signal of interest by a linear…
Purpose: To provide a simulation framework for routine neuroimaging test data, which allows for "stress testing" of deep segmentation networks against acquisition shifts that commonly occur in clinical practice for T2 weighted (T2w) fluid…
We develop a simple method for measuring the electron spin relaxation times $T_1$, $T_2$ and $T_2^*$ in semiconductors and demonstrate its exemplary application to $n$-type GaAs. Using an abrupt variation of the magnetic field acting on…
Today the gold standard for in vivo imaging through scattering tissue is the point-scanning two-photon microscope (PSTPM). Especially in neuroscience, PSTPM is widely used for deep-tissue imaging in the brain. However, due to sequential…
Patient motion is well-known for degrading image quality during medical imaging. Especially positron emission tomography (PET) is susceptible to motion due to its usually long scan times. In hybrid PET/MRI (magnetic resonance imaging),…
We consider a missing data problem in the context of automatic segmentation methods for Magnetic Resonance Imaging (MRI) brain scans. Usually, automated MRI scan segmentation is based on multiple scans (e.g., T1-weighted, T2-weighted, T1CE,…
Reliable low-latency gravitational wave parameter estimation is essential to target limited electromagnetic followup facilities toward astrophysically interesting and electromagnetically relevant sources of gravitational waves. In this…
Sparse-view computed tomography (CT) is known as a widely used approach to reduce radiation dose while accelerating imaging through lowered projection views and correlated calculations. However, its severe imaging noise and streaking…
Accurate skull-stripping is crucial preprocessing in dynamic susceptibility contrast-enhanced perfusion magnetic resonance data analysis. The presence of non-brain tissues impacts the perfusion parameters assessment. In this study, we…
Coherent spin resonance techniques, such as nuclear and electron spin resonance spectroscopy, have revolutionized non-invasive imaging by providing spectrally resolved information about spin dynamics. Motivated by the recent emergence of…
Currently, the deep neural network is the mainstream for machine learning, and being actively developed for biomedical imaging applications with an increasing emphasis on tomographic reconstruction for MRI, CT, and other imaging modalities.…