BiDAQ is a custom filtering and data acquisition system designed for next-gen bolometric experiments dedicated to the search of neutrinoless double beta decay. The system is composed of 12-channel analog-to-digital boards interfaced with…
The CROSS experiment will search for neutrinoless double-beta decay using a specific mechanical structure to hold thermal detectors. The design of the structure was tuned to minimize the background contribution, keeping an optimal detector…
With present-day detectors in high energy physics one often faces fast analog pulses of a few nanoseconds length which cover large dynamic ranges. In many experiments both amplitude and timing information have to be measured with high…
At present, fast waveform digitizing circuit is more and more employed in modern physics experiments for processing the signals from an array detector. A new fast waveform sampling digitizing circuit developed by us is presented in this…
We present the design of a new $\mu$TCA-based waveform digitizer, which will be deployed in the Muon g-2 experiment at Fermilab and will allow our pileup identification requirement to be met. This digitizer features five independent…
An ultra-high-speed waveform digitizer prototype based on gigabit Ethernet has been developed. The prototype is designed to read out signals of detectors to realize the accurate measurement of various physical quantities for plasma…
This study presents a novel field-programmable gate array (FPGA)-based Time-to-Digital Converter (TDC) design suitable for high timing resolution applications, utilizing two new techniques. First, a cross-detection (CD) method is introduced…
Neutrinoless double beta ($0\nu\beta\beta$) decay is a hypothetical rare nuclear transition ($T_{1/2}>10^{26}$ y). Its observation would provide an important insight about the nature of neutrinos (Dirac or Majorana particle) demonstrating…
This manuscript describes a radiation-hardened current-mode delta-sigma ADC fabricated in a standard 130 nm CMOS technology and qualified for total ionizing doses up to 100 Mrad. The operational signal range achieved with a 100 s…
A dedicated 4{\pi}{\beta} (LS)-{\gamma} (HPGe)digital coincidence system has been developed in this work, which includes five acquisition channels. Three analog-to-digital converter (ADC) acquisition channels with an acquisition resolution…
An FPGA based digital signal processing (DSP) system for biasing and reading out multiplexed bolometric detectors for mm-wavelength telescopes is presented. This readout system is being deployed for balloon-borne and ground based cosmology…
In recent years, high speed and high resolution analog-to-digital converter (ADC) is widely employed in many physical experiments, especially in high precision time and charge measurement. The rapid increasing amount of digitized data…
We introduce the waveform capture device (WCD), a flexible measurement system capable of recording complex digital signals on trillionth-of-a-second (ps) time scales. The WCD is implemented via modular code on an off-the-shelf…
Side-Channel Analysis (SCA) requires the detection of the specific time frame Cryptographic Operations (COs) takeplace in the side-channel signal. In laboratory conditions with full control over the Device under Test (DuT), dedicated…
The analog signals generated in the read-out electronics of radiation detectors are shaped prior to the digitization in order to improve the signal to noise ratio (SNR). The real amplitude of the analog signal is then obtained using digital…
Neutrinoless double-beta decay is a key process in particle physics. Its experimental investigation is the only viable method that can establish the Majorana nature of neutrinos, providing at the same time a sensitive inclusive test of…
Time-tagging units and coincidence detectors are used in many scientific research fields. The required timing resolution and number of input channels are varying, but some emerging experiments in the field of quantum optics require up to 32…
The GANDALF 6U-VME64x/VXS module has been designed to cope with a variety of readout tasks in high energy and nuclear physics experiments, in particular the COMPASS experiment at CERN. The exchangeable mezzanine cards allow for an…
We have developed a digital fast Fourier transform (FFT) spectrometer made of an analog-to-digital converter (ADC) and a field-programmable gate array (FPGA). The base instrument has independent ADC and FPGA modules, which allow us to…