Related papers: A Compton polarimeter using scintillators read out…
We review the basic principles of X-ray polarimetry and current detector technologies based on the photoelectric effect, Bragg reflection, and Compton scattering. Recent technological advances in high-spatial-resolution gas-filled X-ray…
Positron Emission Tomography (PET) is a medical imaging modality that utilizes positron-emitting isotopes, such as Ga-68 and F-18, for many diagnostic purposes. The positron annihilates with an electron from the surrounding area, creating…
This paper reviews the development status of GRAPE (the Gamma-Ray Polarimeter Experiment), a hard X-ray Compton Polarimeter. The purpose of GRAPE is to measure the polarization of hard X-rays in the 50-300 keV energy range. We are…
Muon scattering tomography is a non-destructive technique used to image different materials by utilizing natural cosmic ray muons. Typically it requires position-sensitive detectors with a sub-millimeter resolution to effectively…
X-ray polarimetry promises to give qualitatively new information about high-energy astrophysical sources, such as binary black hole systems, micro-quasars, active galactic nuclei, and gamma-ray bursts. We designed, built and tested a hard…
Gamma-ray polarization offers a unique probes into the geometry of the gamma-ray emission process in celestial objects. The Soft Gamma-ray Detector (SGD) onboard the X-ray observatory Hitomi is a Si/CdTe Compton camera and is expected to be…
The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate…
A number of techniques are being developed to solve the monstrous sensitivity gap that exists between the energy ranges of good sensitivity of the Compton and of the pair telescopes and to extend polarimetry to the MeV gamma-ray world. I…
The J-PET detector, which consists of inexpensive plastic scintillators, has demonstrated its potential in the study of fundamental physics. In recent years, a prototype with 192 plastic scintillators arranged in 3 layers has been optimized…
A barrel-shaped plastic scintillation counter with Multi-Pixel Photon Counter (MPPC) readout has been developed and operated in the first WASA-FRS experimental campaign at GSI. The detector was used to measure charged particles emitted from…
It has been recently proposed (Boggs, Nucl. Instr. and Meth. A 503 (2003) 562), to use polarization of Compton scattered gamma-rays to improve the imaging performance of Compton telescopes. Building upon that work, we detected the…
Development of multi-layer optics makes feasible the use of X-ray telescope at energy up to 60-80 keV: in this paper we discuss the extension of photoelectric polarimeter based on Micro Pattern Gas Chamber to high energy X-rays. We…
Exciton-polaritons, elementary excitations arising from the strong coupling regime between photons and excitons in insulators or semiconductors, represent a promising platform for studying quantum fluids of light and realizing prospective…
A combination of scintillator, wavelength shifting (WLS) fiber, and silicon photomultiplier (SiPM) shows an excellent performance in the `$K_{L}$ and $\mu$ detector (KLM)' of the Belle II experiment. In this study, we present the R&D…
Our Sun is the closest X-ray astrophysical source to Earth. As such, it makes a formidable case study to better understand astrophysical processes. Solar flares are in particular very interesting as they are linked to coronal mass ejections…
Measurements of the linear polarization of high-energy emission from pulsars, accreting black holes, and gamma-ray bursts (GRBs) provide an opportunity for constraining the emission mechanisms and geometries (e.g., of the accretion disk,…
While the scientific potential of high-energy X-ray and gamma-ray polarimetry has long been recognized, measuring the polarization of high-energy photons is challenging. To date, there has been very few significant detections from an…
Application of cubesats in astronomical observations has been getting more and more mature in recent years. Here we report a concept study of a small Compton polarimeter to fly on a cubesat for observing polarization of soft gamma-rays from…
We report on the design and estimated performance of a balloon-borne hard X-ray polarimeter called HX-POL. The experiment uses a combination of Si and Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV X-rays…
POLAR is a compact polarimeter dedicated to measure the polarization of GRBs between 50-300 keV. The light collection of 200*6*6mm3 plastic bars has been simulated and optimized in order to get uniform response to x-rays at different points…