Related papers: A Compton polarimeter using scintillators read out…
We report on Monte Carlo studies of the hard X-ray polarimeter X-Calibur. The polarimeter will be used in the focal plane of a grazing incidence hard X-ray telescope. It combines a low-Z Compton scatterer with a high-Z Cadmium Zinc…
An innovative particle detector that offers a compelling combination of cost-effectiveness and high accuracy is introduced. The detector features plastic scintillators paired with a sparse arrangement of SiPMs, strategically positioned…
J-PET is the first positron-emission tomograph (PET) constructed from plastic scintillators. It was optimized for the detection of photons from electron-positron annihilation. Such photons, having an energy of 511 keV, interact with…
We propose a new scintillator-based tracker concept based on a monolithic plastic scintillator plate with embedded scatterers and wavelength-shifting fiber readout. The embedded scatterers localize scintillation light so that channels…
J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons…
We report on the optimization of the hard X-ray polarimeter X-Calibur for a high-altitude balloon-flight in the focal plane of the InFOC{\mu}S X-ray telescope from Fort Sumner (NM) in Fall 2013. X-Calibur combines a low-Z scintillator slab…
The development of multi-layer optics which allow to focus photons up to 100 keV and more promises an enormous jump in sensitivity in the hard X-ray energy band. This technology is already planned to be exploited by future missions…
Synchrotron radiation facilities provide highly polarized X-ray beams across a wide energy range. However, the exact type and degree of polarization varies according to the beamline and experimental setup. To accurately determine the angle…
In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1…
We are designing an all-scintillator Compton gamma imager for use in security investigations and remediation actions involving radioactive threat material. To satisfy requirements for a rugged and portable instrument, we have chosen solid…
Detection of $\gamma$-ray polarization in Positron Emission Tomography (PET) is as yet an unexploited feature that could be used as an additional handle to improve signal-to-background ratio in this imaging modality. The $\gamma$…
We present the results of the first high-altitude balloon flight test of a concept for an advanced Compton telescope making use of modern scintillator materials with silicon photomultiplier (SiPM) readouts. There is a need in the fields of…
This paper presents the model-based design and evaluation of an instrument that estimates incident neutron direction using the kinematics of neutron scattering by hydrogen-1 nuclei in an organic scintillator. The instrument design uses a…
Measurement of gamma-ray polarization can provide valuable insight in different areas of physics. A possible application is in Positron Emission Tomography, where annihilation quanta with orthogonal polarizations are emitted. Since…
Constancy and anisotropy of vacuum refractive index serves as a strong way to probe the predictions of theories beyond the standard model (BSM), especially those that predict breaking of local Lorentz and CPT symmetries. For photons of…
For a long time, scintillator detectors have suffered from relatively weak spatial resolution due to various influencing factors. Additionally, the high cost of photomultiplier tubes (PMTs) has limited the widespread adoption of…
Linear polarization in X- and gamma-rays is an important diagnostic of many astrophysical sources, foremost giving information about their geometry, magnetic fields, and radiation mechanisms. However, very few X-ray polarization…
We describe a new balloon-borne instrument (PoGOLite) capable of detecting 10% polarisation from 200mCrab point-like sources between 25 and 80keV in one 6 hour flight. Polarisation measurements in the soft gamma-ray band are expected to…
A Compton gamma imager has been developed for use in consequence management operations and in security investigations. The imager uses solid inorganic scintillator, known for robust performance in field survey conditions. The design was…
The precise measurements of the Compton scatterings of photons originating from the decay of positronium atoms can reveal information about their polarizations. J-PET detector is constructed of 192 plastic scintillators and is unique to…