Related papers: Simple precision measurements of optical beam size…
An optical analog of the quantum weak measurement scheme proved to be very useful for the observation of optical beam shifts. Here we adapt the weak value amplification method for the observation of the angular Goos-Hanchen shift. We…
The manipulation and metrology of light beams are pivotal for optical science and applications. In particular, achieving ultra-high precision in the measurement of light beam rotations has been a long-standing challenge. Instead of…
We report on the highest precision yet achieved in the measurement of the polarization of a low energy, $\mathcal{O}$(1 GeV), electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall~C at Jefferson…
A Bayesian model to infer edge electron density profiles is developed for the JET lithium beam emission spectroscopy system, measuring Li I line radiation using 26 channels with ~1 cm spatial resolution and 10~20 ms temporal resolution. The…
We show that it is possible to independently control both the trajectory and the maximum amplitude along the trajectory of a paraxial accelerating beam. This is accomplished by carefully engineering both the amplitude and the phase of the…
When measuring diameters of partially resolved sources often a technique called gaussian deconvolution is used. This technique yields a gaussian diameter which subsequently has to be multiplied with a conversion factor to obtain the true…
We present a method for determining the 3D intensity distribution of directed laser radiation with micrometer resolution in restricted volumes. Our method is based on in-coupling and guiding properties of optical fibers, with the current…
We show how it is possible to controllably rotate or align microscopic particles of isotropic nonabsorbing material in a TEM00 Gaussian beam trap, with simultaneous measurement of the applied torque using purely optical means. This is a…
In this paper, we consider the estimation of a change-point for possibly high-dimensional data in a Gaussian model, using a k-means method. We prove that, up to a logarithmic term, this change-point estimator has a minimax rate of…
We develop a formulation of the Baade-Wesselink method which uses the Fourier coefficients of the observables. We derive an explicit, analytic expression to determine the mean radius from each Fourier order. The simplicity of this method…
Compared to contact sensors-based motion measurement, vision-based motion measurement has advantages of low cost and high efficiency and have been under active development in the past decades. This paper provides a review on existing motion…
Laser beam profilometry is an important scientific task with well-established solutions for beams propagating in air. It has, however, remained an open challenge to measure beam profiles of high-power lasers in ultra-high vacuum and in…
We report an $\textit{in situ}$ mass measurement of approximately-$4.7{\text -}\mu$m-diameter, optically levitated microspheres with an electrostatic co-levitation technique. The mass of a trapped, charged microsphere is measured by holding…
Improving axial resolution is of paramount importance for three-dimensional optical imaging systems. Here, we investigate the ultimate precision in axial localization using vortex beams. For Laguerre-Gauss beams, this limit can be achieved…
In this paper, direct sampling method is considered for determining the location of a set of small, linear perfectly conducting cracks from the collected far-field data corresponding to an incident field. To show the feasibility of the…
The signal registered by a plane photodetector placed behind an optically inhomogeneous object irradiated by two coherent Gaussian beams intersecting inside the object at small angle to each other is calculated in the single-scattering…
Obtaining accurate photometry of bright stars from the ground remains tricky because of the danger of overexposure of the target and/or lack of suitable nearby comparison star. The century-old method of the objective wire mesh used to…
An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with…
Transverse 2D phase space distribution of a 2.1 MeV, 5 mA H$^-$ beam is measured at the PIPIT test accelerator at Fermilab with an Allison scanner. The paper describes the design, calibration, and performance of the scanner as well as the…
In optical metrological protocols to measure physical quantities, it is, in principle, always beneficial to increase photon number to improve measurement precision. However, practical constraints prevent arbitrary increase of n due to the…