Related papers: Calibration of cryogenic amplification chains usin…
Cryogen-free low-temperature setups are becoming more prominent in experimental science due to their convenience and reliability, and concern about the increasing scarcity of helium as a natural resource. Despite not having any moving parts…
The nonlinear energy response of cryogenic microcalorimeters is usually corrected through an empirical calibration. X-ray or gamma-ray emission lines of known shape and energy anchor a smooth function that generalizes the calibration data…
It is generally considered that the signal output by a quantum circuit is attenuated exponentially fast in the number of gates. This letter explores how algorithms using mid-circuit measurements and classical conditioning as computational…
The inductive charging of electric vehicles requires specific measurement and calibration systems. In fact, the measurement of power on board involves DC signals, which are superimposed to a significant AC ripple up to or over 150 kHz,…
The quest to enhance the sensitivity of electron spin resonance (ESR) is an ongoing challenge. One potential strategy involves increasing the frequency, for instance, moving from Q-band (approximately 35 GHz) to W-band (approximately 94…
The gain of silicon photomultipliers (SiPMs) increases with bias voltage and decreases with temperature. To operate SiPMs at stable gain, the bias voltage can be readjusted to compensate for temperature changes. We have tested this concept…
A vacuum compatible cryogenic accelerometer is presented which will reach $<0.5$ p$g$ Hz$^{-1/2}$ sensitivity from 1 mHz to 10 Hz with a maximum sensitivity of 10 f$g$ Hz$^{-1/2}$ around 10 Hz. This figure can be translated to a…
This paper describes the setup and the results of the direct on-wafer measurements of a FET noise parameters obtained with a source-pull method at temperatures down to T=4K and in the 5-12 GHz frequency range. The setup consists of a…
With the demand for scalable cryogenic microwave circuitry continuously rising, recently developed flexible microwave striplines offer the tantalyzing perspective of increasing the cabling density by an order of magnitude without thermally…
We have developed a highly-sensitive integrated capacitance bridge for quantum capacitance measurements. Our bridge, based on a GaAs HEMT amplifier, delivers attofarad (aF) resolution using a small AC excitation at or below kT over a broad…
We describe a kinetic inductance traveling-wave (KIT) amplifier suitable for superconducting quantum information measurements and characterize its wideband scattering and noise properties. We use mechanical microwave switches to calibrate…
State-of-the-art physics experiments require high-resolution, low-noise, and low-threshold detectors to achieve competitive scientific results. However, experimental environments invariably introduce sources of noise, such as electrical…
This paper describes the developed setup and characterization approach for full two-port calibrated S-parameter measurements at cryogenic temperatures, together with a complete uncertainty budget. The system developed at the Istituto…
A process which strongly amplifies both quadrature amplitudes of an oscillatory signal necessarily adds noise. Alternatively, if the information in one quadrature is lost in phase-sensitive amplification, it is possible to completely…
Fluctuations of the current through a tunnel junction are measured using a Josephson junction. The current noise adds to the bias current of the Josephson junction and affects its switching out of the supercurrent branch. The experiment is…
We report what we believe to be the first radiation-balanced fiber amplifier - a device that provides optical gain while experiencing no temperature rise. The gain medium is a silica fiber with a 21 um-diameter core highly doped with Yb3+…
A compact cryogenic calibration target is presented that has a peak diffuse reflectance, $R \le 0.003$, from $800-4,800\,{\rm cm}^{-1}$ $(12-2\,\mu$m). Upon expanding the spectral range under consideration to $400-10,000\,{\rm cm}^{-1}$…
We theoretically investigate heat transport in hybrid normal metal-superconductor (NS) nanojunctions focusing on the effect of thermal rectification. We show that the heat diode effect in the junction strongly depends on the transmissivity…
Arrays of Josephson junctions can be tuned through anomalous metallic, quantum-critical, and insulating regimes. We introduce a new experimental probe, capturing microwave radiation across all three regimes, using a two-dimensional array of…
Recently, great progress has been made in the field of ultrasensitive microwave detectors, reaching even the threshold for utilization in circuit quantum electrodynamics. However, cryogenic sensors lack the compatibility with broad-band…