English
Related papers

Related papers: Calibration of cryogenic amplification chains usin…

200 papers

Josephson superconducting qubits and parametric amplifiers are prominent examples of superconducting quantum circuits that have shown rapid progress in recent years. With the growing complexity of such devices, the requirements for…

We apply noise thermometry to characterize charge and thermoelectric transport in single InAs nanowires (NWs) at a bath temperature of 4.2 K. Shot noise measurements identify elastic diffusive transport in our NWs with negligible…

Mesoscale and Nanoscale Physics · Physics 2016-10-03 E. S. Tikhonov , D. V. Shovkun , V. S. Khrapai , D. Ercolani , F. Rossella , M. Rocci , L. Sorba , S. Roddaro

We report on experiments performed in vacuum and at cryogenic temperatures on a tri-port nano-electro-mechanical (NEMS) device. One port is a very non-linear capacitive actuation, while the two others implement the magnetomotive scheme with…

Mesoscale and Nanoscale Physics · Physics 2015-12-02 E. Collin , M. Defoort , K. Lulla , T. Moutonet , J. -S. Heron , O. Bourgeois , Yu. M. Bunkov , H. Godfrin

A Kinetic Inductance Traveling Wave amplifier (KIT) utilizes the nonlinear kinetic inductance of superconducting films, particularly Niobium Titanium Nitride (NbTiN), for parametric amplification. These amplifiers achieve remarkable…

Quantum Physics · Physics 2024-12-16 A. Giachero , M. Vissers , J. Wheeler , L. Howe , J. Gao , J. Austermann , J. Hubmayr , A. Nucciotti , J. Ullom

A robust cryogenic infrastructure in form of a wired, thermally optimized dilution refrigerator is essential for present and future solid-state based quantum processors. Here, we engineer an extensible cryogenic setup, which minimizes…

The simulation of vibrational energy transport and quantum thermodynamics with trapped ions requires good methods for the estimation of temperatures. One valuable tool for this purpose is based on the fit of dark resonances in the…

High-fidelity single-shot readout of spin qubits requires distinguishing states much faster than the T1 time of the spin state. One approach to improving readout fidelity and bandwidth (BW) is cryogenic amplification, where the signal from…

We present herein gain stabilization studies of SiPMs using a climate chamber at CERN. We present results for four detectors not tested before, three from Hamamatsu and one from KETEK. Two of the Hamamatsu SiPMs are novel sensors with…

Instrumentation and Detectors · Physics 2016-03-02 Gerald Eigen , Are Træet , Justas Zalieckas , Jaroslav Cvach , Jiri Kvasnicka , Ivo Polak

We develop Johnson noise thermometry applicable to mesoscopic devices with variable source impedance with high bandwidth for fast data acquisition. By implementing differential noise measurement and two-stage impedance matching, we…

Instrumentation and Detectors · Physics 2021-04-15 Artem Vladimirovich Talanov , Jonah Waissman , Takashi Taniguchi , Kenji Watanabe , Philip Kim

Thermocurrent flowing through a single-molecule device contains valuable information about the quantum properties of the molecular structure and, in particular, on its electronic and phononic excitation spectra, and entropy. Furthermore,…

Mesoscale and Nanoscale Physics · Physics 2023-02-24 Serhii Volosheniuk , Damian Bouwmeester , Chunwei Hsu , H. S. J. van der Zant , Pascal Gehring

The amplification of the superconducting critical temperature Tc from the low temperature range in homogeneous 2D planes (Tc<23 K) to the high temperature range (23 K<Tc<150 K) in an artificial heterostructure of quantum stripes is…

Superconductivity · Physics 2011-07-19 Andrea Perali , Antonio Bianconi , Alessandra Lanzara , Naurang L. Saini

We demonstrate that substantial power gain can be obtained with superconducting transition detectors. We describe the properties of the detector as a power amplifier theoretically. In our first experiments power gain of 23 was reached in a…

Superconductivity · Physics 2008-06-18 P. Helistö , J. Hassel , A. Luukanen , H. Seppä

Microwave quantum technologies require amplification of weak signals with minimal added noise at millikelvin temperatures. This stringent demand has been met with superconducting parametric amplifiers. While masers offer another fundamental…

In this paper we demonstrate experimentally the implementation of a niobium-trilayer junction with an aluminum-oxide tunnel barrier, embedded in a high-gap superconducting niobium-titanium-nitride circuit. Previously reported heating by…

Mesoscale and Nanoscale Physics · Physics 2013-09-30 M. P. Westig , S. Selig , K. Jacobs , T. M. Klapwijk , C. E. Honingh

Non-Gaussian fluctuations of the electrical current can be detected with a Josephson junction placed on-chip with the noise source. We present preliminary measurements with an NIS junction as a noise source, and a Josephson junction in the…

Mesoscale and Nanoscale Physics · Physics 2007-11-06 B. Huard , H. Pothier , Norman O. Birge , D. Esteve , X. Waintal , J. Ankerhold

Hybrid superconductor/semiconductor devices constitute a powerful platform to investigate the emergence of new topological state of matter. Among all possible semiconductor materials, InAs represents a promising choice, owing to its high…

Cryogenic CMOS technology (cryo-CMOS) offers a scalable solution for quantum device interface fabrication. Several previous works have studied the characterization of CMOS technology at cryogenic temperatures for various process nodes.…

Applied Physics · Physics 2019-02-20 Chao Luo , Zhen Li , TengTeng Lu , Jun Xu , GuoPing Guo

Recent experiments showed that thinning gallium, iron selenide and 2H tantalum disulfide to single/several monoatomic layer(s) enhances their superconducting critical temperatures. Here, we characterize these superconductors by extracting…

Superconductivity · Physics 2017-03-30 Evgeny Talantsev , Wayne Crump , Joshua Island , Ying Xing , Yi Sun , Jian Wang , Jeffery Tallon

We developed a method to infer the calibration parameters of multichannel measurement systems, such as channel variations of sensitivity and noise amplitude, from experimental data. We regard such uncertainties of the calibration parameters…

Applications · Statistics 2017-03-08 Keisuke Fujii , Ichihiro Yamada , Masahiro Hasuo

Precise temperature monitoring -- to the level of a few milli-Kelvin -- is essential for the operation of large-scale cryostats requiring a recirculation system. In particular, the performance of Liquid Argon Time Projection Chambers --…

Instrumentation and Detectors · Physics 2025-06-09 Maria Antonova , Jordi Capó , Anselmo Cervera , Pablo Fernández , Miguel Á. García-Peris , Xavier Pons