English
Related papers

Related papers: Triplet Lifetime in Gaseous Argon

200 papers

The MiniCLEAN dark matter experiment will exploit a single-phase liquid-argon detector instrumented with 92 photomultiplier tubes placed in the cryogen temperature with 4-$\pi$ coverage of a 500 kg (150 kg) target (fiducial) mass. The…

Instrumentation and Detectors · Physics 2017-11-08 JuiJen , Wang

LEGEND-200 requires high-purity liquid argon for effective background discrimination. In this paper, we present the design, construction, and performance of a dedicated liquid argon purification system, along with the procurement and…

The MiniCLEAN dark matter experiment will exploit a single-phase liquid-argon detector instrumented with photomultiplier tubes submerged in the cryogen with nearly 4pi coverage of a 500 kg (150 kg) target (fiducial) mass. The high light…

Instrumentation and Detectors · Physics 2011-10-06 Andrew Hime

The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic…

Liquid argon is used as active medium in a variety of neutrino and Dark Matter experiments thanks to its excellent properties of charge yield and transport and as a scintillator. Liquid argon scintillation photons are emitted in a narrow…

Instrumentation and Detectors · Physics 2021-02-10 Ettore Segreto

While developing a liquid argon detector for dark matter searches we investigate the influence of air contamination on the VUV scintillation yield in gaseous argon at atmospheric pressure. We determine with a radioactive alpha-source the…

Instrumentation and Detectors · Physics 2010-01-28 C. Amsler , V. Boccone , A. Buchler , R. Chandrasekharan , C. Regenfus , J. Rochet

The scintillation light of liquid argon has been recorded wavelength and time resolved with very good statistics in a wavelength interval ranging from 118 nm through 970 nm. Three different ion beams, protons, sulfur ions and gold ions,…

Instrumentation and Detectors · Physics 2015-11-25 M. Hofmann , T. Dandl , T. Heindl , A. Neumeier , L. Oberauer , W. Potzel , S. Roth , S. Schönert , J. Wieser , A. Ulrich

We report results from a 13-liter purified liquid argon test stand at Wellesley College. The system includes a single-pass liquid-phase purification column, a double-gridded purity monitor to assess the electron lifetime, and a slow control…

A dedicated test of the effects of Oxygen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. Two detectors have been used: the WArP 2.3 lt prototype and a small (0.7…

We report on a measurement of the attenuation length for the scintillation light in the tonne size liquid argon target of the ArDM dark matter experiment. The data was recorded in the first underground operation of the experiment in…

The DarkSide-50 (DS-50) experiment aims at the direct detection of weakly interacting massive particles. It is a dual-phase liquid argon time projection chamber (LAr TPC) where Dark Matter (DM), which constitutes five sixths of all matter…

Instrumentation and Detectors · Physics 2024-10-29 Clea Sunny

Noble gas and liquid detectors rely on high chemical purity for successful operation. While gaseous purification has emerged as a reliable method of producing high-purity noble fluids, the requirement for large mass flows drives the…

Instrumentation and Detectors · Physics 2024-10-11 Christoph Vogl , Mario Schwarz , Patrick Krause , Grzegorz Zuzel , Stefan Schönert

A dedicated test of the effects of Nitrogen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. A detector has been designed and assembled for this specific task and…

A key feature for the success of the liquid Argon imaging TPC (LAr-TPC) technology is the industrial purification against electro-negative impurities, especially Oxygen and Nitrogen remnants, which have to be continuously kept at an…

We report on a measurement of the absorption length of scintillation light in liquid argon due to dissolved nitrogen at the part-per-million (ppm) level. We inject controlled quantities of nitrogen into a high purity volume of liquid argon…

Instrumentation and Detectors · Physics 2015-06-16 B. J. P. Jones , C. S. Chiu , J. M. Conrad , C. M. Ignarra , T. Katori , M. Toups

In this paper we present a successful experimental test of filling a volume of 6 m$^3$ with argon gas, starting from normal ambient air and reducing the impurities content down to few parts per million (ppm) oxygen equivalent. This level of…

The $3 \times 1 \times 1$ m$^3$ demonstrator is a dual phase liquid argon time projection chamber that has recorded cosmic rays events in 2017 at CERN. The light signal in these detectors is crucial to provide precise timing capabilities.…

Instrumentation and Detectors · Physics 2021-03-24 B. Aimard , L. Aizawa , C. Alt , J. Asaadi , M. Auger , V. Aushev , D. Autiero , A. Balaceanu , G. Balik , L. Balleyguier , E. Bechetoille , D. Belver , A. M. Blebea-Apostu , S. Bolognesi , S. Bordoni , N. Bourgeois , B. Bourguille , J. Bremer , G. Brown , G. Brunetti , L. Brunetti , D. Caiulo , M. Calin , E. Calvo , M. Campanelli , K. Cankocak , C. Cantini , B. Carlus , B. M. Cautisanu , M. Chalifour , A. Chappuis , N. Charitonidis , A. Chatterjee , A. Chiriacescuf , P. Chiu , S. Conforti , P. Cotte , P. Crivelli , C. Cuesta , J. Dawson , I. De Bonis , C. De La Taille , A. Delbart , S. Di Luise , F. Doizon , C. Drancourt , D. Duchesneau , F. Dulucq , F. Duval , S. Emery , A. Ereditato , A. Falcone , K. Fusshoeller , A. Gallego-Ros , V. Galymov , N. Geffroy , A. Gendotti , A. Gherghel-Lascu , I. Gil-Botella , C. Girerd , M. C. Gomoiu , P. Gorodetzky , E. Hamada , R. Hanni , T. Hasegawa , A. Holin , S. Horikawa , M. Ikeno , S. Jiménez , A. Jipa , M. Karolak , Y. Karyotakis , S. Kasai , K. Kasami , T. Kishishita , H. Konari , I. Kreslo , D. Kryn , P. Kunzé , M. Kurokawa , Y. Kuromori , C. Lastoria , I. Lazanu , G. Lehmann-Miotto , M. Leyton , N. Lira , K. Loo , D. Lorca , P. Lutz , T. Lux , J. Maalampi , G. Maire , M. Maki , L. Manenti , R. M. Margineanu , J. Marteau , G. Martin-Chassard , H. Mathez , E. Mazzucato , G. Misitano , D. Mladenov , L. Molina Bueno , T. S. Mosu , W. Mu , S. Murphy , K. Nakayoshi , S. Narita , D. Navas-Nicolás , K. Negishi , M. Nessi , M. Niculescu-Oglinzanu , F. Noto , A. Noury , Y. Onishchuk , C. Palomares , M. Parvu , T. Patzak , Y. Penichot , E. Pennacchio , L. Periale , H. Pessard , F. Pietropaolo , D. Pugnere , B. Radics , D. Redondo , C. Regenfus , A. Remoto , F. Resnati , O. Ristea , A. Rubbia , A. Saftoiu , K. Sakashita , F. Sanchez , C. Santos , A. Scarpelli , C. Schloesser , K. Sendai , F. Sergiampietri , S. Shahsavarani , M. Shoji , J. Sinclair , J. Soto-Oton , D. I. Stanca , D. Stefan , R. Sulej , M. Tanaka , V. Toboaru , A. Tonazzo , W. Tromeur , W. H. Trzaska , T. Uchida , L. Urda , F. Vannucci , G. Vasseur , A. Verdugo , T. Viant , S. Vihonen , S. Vilalte , M. Weber , S. Wu , J. Yu , L. Zambelli , M. Zito

In this paper we present a compact test facility for the measurement of optical properties of liquid argon as scintillator. The setup is under preparation at Roma Tre and it has a volume of 40 L liquid argon, which is liquefied from argon…

Instrumentation and Detectors · Physics 2026-02-24 Hexi Shi , Valerio D'Andrea , Giuseppe Salamanna , Krzysztof Szczepaniec , Diego Tagnani

The propagation velocity of scintillation light in liquid argon $v_{g}$ at $\lambda \sim 128$~nm wavelength, has been measured for the first time in a dedicated experimental setup at CERN.\\ The obtained result $\frac{1}{v_{g}} = 7.46 \pm…

Instrumentation and Detectors · Physics 2021-07-30 M. Babicz , S. Bordoni , A. Fava , U. Kose , M. Nessi , F. Pietropaolo , G. L. Raselli , F. Resnati , M. Rossella , P. Sala , F. Stocker , A. Zani

Future giant liquid argon (LAr) time projection chambers (TPCs) require a purity of better than 0.1 parts per billion (ppb) to allow the ionised electrons to drift without significant capture by any electronegative impurities. We present a…

Instrumentation and Detectors · Physics 2015-05-28 K. Mavrokoridis , R. G. Calland , J. Coleman , P. K. Lightfoot , N. McCauley , K. J. McCormick , C. Touramanis
‹ Prev 1 2 3 10 Next ›