Related papers: In-air ion beam analysis with high spatial resolut…
Proton scattering in some water and tissue equivalent phantom materials was measured to evaluate their simulation accuracy of water and respective human biological tissues. The measurements were performed on the medical facility of the ITEP…
Raman microscopy is a valuable tool for detecting physical and chemical properties of a sample material. When probing nanomaterials or nanocomposites the spatial resolution of Raman microscopy is not always adequate as it is limited by the…
Plasma impedance probes (PIPs) are a type of RF probe that primarily measure electron density. This work introduces two advancements: a streamlined analytical model for interpreting PIP-monopole measurements and techniques for achieving…
The determination of relative stopping power (RSP) via proton computed tomography (pCT) of a patient is dependent in part on the knowledge of the incoming proton kinetic energies; the uncertainty in these energies is in turn determined by…
Ion acceleration using a laser pulse irradiating a thin disk target is examined using three-dimensional and two-dimensional particle-in-cell simulations. A laser pulse of $620$ TW, with an intensity of $5\times 10^{21}$ W/cm$^{2}$ and a…
We present the design and construction of our experimental setup for studying the transmission of proton microbeam through a single, cylindrical shape, macroscopic insulating capillary. The intensity as a function of time, the energy…
Continued dimensional scaling of semiconductor devices has driven information technology into vastly diverse applications. As the size of devices approaches fundamental limits, metrology techniques with nanometre resolution and…
Driven by life-science applications, mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed to image thick biological samples. The high penetration of inelastic scattering signals of MeV electrons could…
The Search for Hidden Particles (SHiP) Collaboration has shown that the CERN SPS accelerator with its 400 $\mathrm{\small GeV/c}$ proton beam offers a unique opportunity to explore the Hidden Sector. The proposed experiment is an intensity…
The Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory has been in operation since 2000. Over the past decade, the luminosity in the polarized proton (p-p) operations has increased by more than one order of magnitude.…
Scattering scanning near-field optical microscopy (s-SNOM) is a technique to enhance the spatial resolution, and when combined by Fourier transform spectroscopy it can provide spectroscopic information with high spatial resolution. This…
We have measured the total energy spread (99 persent energy spread) of the Booster beam at its injection energy of 400 MeV by three different methods - 1) creating a notch of about 40 nsec wide in the beam immediately after multiple turn…
Photothermal-Induced Resonance (PTIR) spectroscopy and imaging with infrared light has seen increasing application in molecular spectroscopy of biological samples. The appeal of the technique lies in its capability to provide information…
Synchrotron radiation with the characteristic of high brilliance, high level of polarization, high collimation, low emittance and wide tunability in energy has been used as a standard source in metrology(1, 2). For a decade, lots of…
Storage rings have been employed over three decades in various kinds of nuclear and atomic physics experiments with highly charged ions. Storage ring operation and precision physics experiments benefit from the availability of beam cooling…
We demonstrate a spatial-imaging thermometry technique for ions in a one-dimensional Coulomb crystal by relating their imaged spatial extent along the linear radiofrequency ion trap axis to normal modes of vibration of coupled oscillators…
Recently, shoot-through proton FLASH has been proposed where the highest energy is extracted from the cyclotron to maximize the dose rate (DR). Even though our proton pencil beam scanning system can deliver 250 MeV (the highest energy), it…
Atomic vibrations control all thermally activated processes in materials including diffusion, heat transport, phase transformations, and surface chemistry. Recent developments in monochromated, aberration-corrected scanning transmission…
In nuclear and atomic physics experiments, charged ion beams often need to be guided from the ion production to the experimental site. In the PUMA experiment, an ion source beamline was developed, which can be operated with up to…
Momentum resolved 4D-STEM, also called center of mass (CoM) analysis, has been used to measure the long range built-in electric field of a silicon p-n junction. The effect of different STEM modes and the trade-off between spatial resolution…