Related papers: Amorphous silicon-based microchannel plate detecto…
Micro-channel plate (MCP)-based photodetectors are capable of picosecond level time resolution and sub-mm level position resolution, which makes them a perfect candidate for the next generation large area photodetectors. The large-area…
Hundreds of concurrent collisions per bunch crossing are expected at future hadron colliders. Precision timing calorimetry has been advocated as a way to mitigate the pileup effects and, thanks to their excellent time resolution,…
Microchannel plates (MCPs) were recently proposed as novel type of cathodes for electron guns, suitable for applications in design of electron lenses. We report results of the first systematic study of microchannel plate based…
A beam imaging detector was developed by coupling a multi-strip anode with delay line readout to an E$\times$B microchannel plate (MCP) detector. This detector is capable of measuring the incident position of the beam particles in…
We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$\mu$m and a resolution of…
Nowadays, Microchannel Plate (MCP), as a kind of electron multipliers based on the secondary electron emission, is widely used in many high-sensitive experiments, such as neutrino detection, which require the noise to be as low as possible,…
Micro-channel-plate-based photo-detectors are unique in being capable of covering areas of many square-meters while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, time…
We describe a high resolution imaging detector based on a single 80 mm micro-channel-plate (MCP) and a phosphor screen mounted on a UHV flange of only 100 mm inner diameter. It relies on standard components and we describe its performance…
A systematic investigation of Planacon MCP-PMTs was performed using 64 XP85002/FIT-Q photosensors. These devices are equipped with microchannel plates of reduced resistance. Results of a study of their gain stability over time and…
We report on the response of microchannel plates (MCPs) to single relativistic particles and to electromagnetic showers. Particle detection by means of secondary emission of electrons at the MCP surface has long been proposed and is used…
Multi Micro-Channel-Plate Photomultiplier tubes (MCP-PMT) with High Collection Efficiency (Hi-CE) MCPs are developed and characterised. With these Hi-CE MCPs more than 90% of photoelectrons emitted from the photocathode can be detected;…
Microchannel plates (MCP) are the basis for many spatially-resolved single-particle detectors such as ICCD or I-sCMOS cameras employing image intensifiers (II), MCPs with delay-line anodes for the detection of cold gas particles or…
Large-Area Picosecond Photo-Detectors (LAPPDs) show great potential for expanding the performance envelope of Micro-Channel Plates (MCPs) to areas of up to 20 x 20 cm and larger. Such scaling introduces new challenges, including how to meet…
A two-dimensional position-sensitive microchannel plate detector, with a {\O}100 mm sensitive area and equipped with four integrated amplifiers, is realized with a new anode scheme. The anode is constructed by two independent…
Micro-channel plate (MCP) detectors, when used at pulsed-neutron-source instruments, offer the possibility of high spatial resolution and high contrast imaging with pixel-level spectroscopic information. Here we demonstrate the possibility…
Hydrogenated amorphous silicon (a-Si:H) has remarkable radiation resistance properties and can be deposited on a lot of different substrates. A-Si:H based particle detectors have been built since mid 1980s as planar p-i-n or Schottky diode…
Microchannel plates (MCPs) were the driving detector technology for ultraviolet (UV) astronomy over many years, and still today MCP-based detectors are the baseline for several planned UV instruments. The development of advanced MCP…
One of the on-going issues with the use of microchannel plates (MCP) in the ionization profile monitors (IPM) at Fermilab is the significant decrease in gain over time. There are several possible issues that can cause this. Historically,…
An Adaptive Spiral Phase Plate (ASPP) based on liquid crystal (LC) and the transmission electrode technique is theoretically and experimentally demonstrated. This ASPP design enables the generation of high-quality optical vortices with…
Ultra-high dose rate radiation therapy (FLASH) based on proton irradiation is of major interest for cancer treatments but creates new challenges for dose monitoring. Amorphous hydrogenated silicon is known to be one of the most…