English
Related papers

Related papers: Performance of a GridPix TPC readout based on the …

200 papers

A GridPix readout for a TPC based on the Timepix3 chip is developed for future applications at a linear collider. The GridPix detector consists of a gaseous drift volume read out by a single Timepix3 chip with an integrated amplification…

Instrumentation and Detectors · Physics 2018-08-23 C. Ligtenberg , K. Heijhoff , Y. Bilevych , K. Desch , H. van der Graaf , F. Hartjes , J. Kaminski , P. M. Kluit , G. Raven , T. Schiffer , J. Timmermans

A gaseous pixel readout module with four GridPix chips, called the quad, has been developed as a building block for a large time projection chamber readout plane. The quad module has dimensions 39.6 mm $\times$ 28.38 mm and an active…

This contribution investigates a prototype of a TPC readout with a highly pixelated CMOS ASIC, which is an option for charged particles tracking of the ILC. A triple GEM stack was joined with a TimePix and MediPix2 chip (pixel size of…

Instrumentation and Detectors · Physics 2009-02-16 A. Bamberger , K. Desch , U. Renz , M. Titov , N. Vlasov , P. Wienemann , S. Zimmermann , A. Zwerger

In this work we have developed a prototype gaseous pixel detector by combining a micromegas grid with a Timepix3 chip for the readout. The micromegas foil supported by a matrix of pillars about 50 $\mathrm{\mu m}$ high was manually placed…

Instrumentation and Detectors · Physics 2019-04-10 S. Tsigaridas , M. v. Beuzekom , H. v. d. Graaf , F. Hartjes , K. Heijhoff , N. P. Hessey , P. J. de Jong , V. Prodanovic

We present measurements with a GEM based TPC prototypes and the TimePix CMOS ASIC as charge collecting anode. Tests with a small prototype were performed in a 5 GeV electron beam at DESY. Different GEM orientations and geometries were…

Instrumentation and Detectors · Physics 2009-02-02 U. Renz

The ARIADNE project is developing innovative optical readout technologies for two-phase liquid Argon time projection chambers (LArTPCs). Optical readout presents an exciting alternative to the current paradigm of charge readout. Optical…

A time projection chamber (TPC) with micropattern gaseous detector (MPGD) readout is investigated as main tracking device of the International Large Detector (ILD) concept at the planned International Linear Collider (ILC). A prototype TPC…

Micro-TPC, a time projection chamber(TPC) with micro pixel chamber($\mu$-PIC) readout was developed for the detection of the three-dimensional fine(sub-m illimeter) tracks of charged particles. We developed a two-dimensional position…

High Energy Physics - Experiment · Physics 2009-11-10 Kentaro Miuchi , Hidetoshi Kubo , Tsutomu Nagayoshi , Atsuhiko Ochi , Reiko Orito , Atsushi Takada , Toru Tanimori , Masaru Ueno

High precision experiments with muons and pions often require tracking charged particles with $O(100~\mu\mathrm{m})$ single-hit resolution, possibly with particle identification capabilities, down to very low momenta ($p \lesssim…

Instrumentation and Detectors · Physics 2023-10-31 G. Cavoto , C. Dutsov , M. Gruber , M. Hildebrandt , T. D. Hume , J. Kaminski , F. Neuhaus , A. Papa , F. Renga , P. Schmidt-Wellenburg , M. Schott , B. Vitali , C. Voena

The ILD concept, one of two proposed detector concepts for the planned International Linear Collider (ILC), foresees a Time Projection Chamber (TPC) as the main tracking detector. The LCTPC (Linear Collider TPC) collaboration pursues R&D to…

Instrumentation and Detectors · Physics 2019-08-15 R. Diener

For the International Large Detector (ILD) at the planned International Linear Collider (ILC) a Time Projection Chamber (TPC) is foreseen as the main tracking detector. To achieve the required point resolution, Micro Pattern Gaseous…

Instrumentation and Detectors · Physics 2019-02-15 Uli Einhaus , Uwe Krämer , Paul Malek

A large volume Time Projection Chamber (TPC) is being considered for the central charged particle tracker for the detector for the proposed International Linear Collider (ILC). To meet the ILC-TPC spatial resolution challenge of ~100…

Instrumentation and Detectors · Physics 2008-11-26 K. Boudjemline , M. S. Dixit , J. -P. Martin , K. Sachs

The TPC for the International Linear Collider (ILC) will need to measure about 200 track points with a transverse resolution close to 100 microns. The resolution goal is beyond the capability of the conventional proportional wire/cathode…

Instrumentation and Detectors · Physics 2008-11-26 M. S. Dixit , A. Rankin

Timepix3 pixel detectors have demonstrated great potential for tracking applications. With $256\times 256$ pixels, 55 $\mathrm{\mu}$m pitch and improved resolution in time (1.56 ns) and energy (2 keV at 60 keV), they have become powerful…

Data Analysis, Statistics and Probability · Physics 2022-02-09 Petr Mánek , Benedikt Bergmann , Petr Burian , Declan Garvey , Lukáš Meduna , Stanislav Pospíšil , Petr Smolyanskiy , Eoghan White

The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD)…

Instrumentation and Detectors · Physics 2022-04-26 M. Dixit , D. Attie , A. Bellerive , K. Boudjemline , P. Colas , P. Giganon , I. Giomataris , V. Lepeltier , S. Liu , J. -P. Martin , K. Sachs , Y. Shin , S. Turnbull

The Time Projection Chamber (TPC) can identify particle species using the energy loss (dE/dx) measured by the readout pad rows. The dE/dx resolution for the ILD (International Large Detector) -TPC for the International Linear Collider…

Instrumentation and Detectors · Physics 2018-01-16 Aiko Shoji

For the advancement of the understanding of timing systematics in pixelized readout chips and for the benefit of future fast timing detectors to aid 4D tracking technology in the HL-LHC, we have performed detailed studies of the timing…

Instrumentation and Detectors · Physics 2022-01-25 R. Geertsema

We report on the development of a novel pixel charge readout system, Grid Activated Multi-scale pixel readout (GAMPix), which is under development for use in the GammaTPC gamma ray instrument concept. GammaTPC is being developed to optimize…

In order to achieve the challenging requirements on the CLIC vertex detector, a range of technology options have been considered in recent years. One prominent idea is the use of active sensors implemented in a commercial high-voltage CMOS…

This paper describes an iterative method of per-pixel energy calibration of hybrid pixel detectors with GaAs:Cr sensor and Timepix readout chip. A convolution of precisely measured spectra of characteristic X-rays of different metals with…

‹ Prev 1 2 3 10 Next ›