Related papers: Timewalk correction for the Timepix3 chip obtained…
A large volume Time Projection Chamber (TPC) is being considered for the central charged particle tracker for the detector for the proposed International Linear Collider (ILC). To meet the ILC-TPC spatial resolution challenge of ~100…
The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the…
New Micromegas (Micro-mesh gaseous detectors) are being developed in view of the future physics projects planned by the COMPASS collaboration at CERN. Several major upgrades compared to present detectors are being studied: detectors…
A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 $\mu$m above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas…
The track timing capabilities of a silicon drift detector based tracker for a future linear electron-positron collider are evaluated. We show such a detector can time tracks at the nanosecond, and for high-$P_{T}$, sub-nanosecond level.…
Reconstruction of tracks of charged particles with high precision is very crucial for HEP experiments to achieve their physics goals. As the tracking detector of BESIII experiment, the BESIII drift chamber has suffered from aging effects…
We report on measurements of 1 and 1.5 MeV monoenergetic electrons with a Timepix3-based detector using a 0.5 mm thick silicon sensor. A $^{90}$Sr $\beta$-emitting radioisotope was used as the source of electrons, and a monochromator…
With the development of the circular collider, it is necessary to make accurate physics experimental measurements of particle properties at higher luminosity $Z$ pole. Micro-pattern gaseous detectors (MPGDs), which contain Gaseous Electron…
During LHC Long Shutdown 3, the ALICE experiment will replace the three innermost layers of its Inner Tracking System (ITS2) with a new vertex detector, the ITS3. This new detector will be assembled using wafer-scale, stitched Monolithic…
The proposed Circular Electron Positron Collider (CEPC) imposes new challenges for the vertex detector in terms of high resolution, low material, fast readout and low power. The Monolithic Active Pixel Sensor (MAPS) technology has been…
The upgrade of the ATLAS muon spectrometer for high-luminosity LHC requires new trigger and readout electronics for the various elements of the detector. We present the design of a time-to-digital converter (TDC) ASIC prototype for the…
A front end ASIC has been designed to equip the {\mu}TPC prototype developed for the MIMAC project, which requires 3D reconstruction of low energy particle tracks in order to perform directional detection of galactic Dark Matter. Each ASIC…
As the Chinese Spallation Neutron Source enters Phase II, the increase in proton beam power will lead to a further boost in the intensity of pulsed neutron beams. To address the demand for higher event-rate readout electronics for…
Silicon tracking detectors provide excellent spatial resolution, and so can provide excellent momentum resolution for energetic charged particles, even in compact detectors. However, at lower momenta, multiple scattering in the silicon…
The current non-linearity correction for the Wide Field Camera 3 Infrared (WFC3/IR) channel is based on ground-based data acquired during WFC3's Thermal Vacuum 3 (TV3) testing campaign. In the current reference file, the correction…
A new downstream tracking system, known as the Mighty Tracker, is planned to be installed at LHCb during LS4 of the LHC. This will allow an increase in instantaneous luminosity from $2\cdot10^{33}~\mathrm{cm}^{-2}\mathrm{s}^{-1}$ to…
The inner drift chamber of the BESIII is encountering serious aging problem after five year's running. For the first layer, the decrease in gas gain is about 26% from 2009 to 2013. The upgrade of the inner tracking detector has become an…
We report measurements of the transverse diffusion of electrons in P-10 gas (90% Ar, 10% CH4) in a laboratory-scale time projection chamber (TPC) utilizing a novel pixelated signal capture and digitization technique known as Q-Pix. The…
In systems with multiple radiation detectors, time synchronization of the data collected from different detectors is essential to reconstruct multi-detector events such as scattering and coincidences. In cases where the number of detectors…
Current and next-generation particle tracking detectors will incorporate precision timing capabilities with resolutions approaching tens of picoseconds. Using Technology Computer-Aided Design (TCAD) simulations of Low-Gain Avalanche Diode…