Abstract

The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. This paper describes the detector mission, setup, construction, installation, commissioning and performance during the first year of sPHENIX data taking.

Cite

@article{arxiv.2403.13789,
  title  = {The sPHENIX Micromegas Outer Tracker},
  author = {S. Aune and B. Azmoun and A. Bonenfant and S. Boose and M. Bregant and D. Cacace and R. W. da Silva and R. Feder and A. Francisco and C. Goblin and A. Grabas and J. S. Haggerty and R. A. Hernandez and H. D. H. Herrera and J. Huang and J. Kelsey and I. Kotov and J. Kuczewski and I. Mandjavidze and T. A. Martins and J. Mead and J. Mills and A. Oskarsson and H. Pereira Da Costa and C. Pinkenburg and R. Pisani and T. Protzman and M. L. Purschke and E. Renner and R. Ruggiero and T. Sakaguchi and B. C. S. Sanches and B. Sayki and D. Silvermyr and W. Sondheim and M. Vandenbroucke and W. A. M. Van Noije and J. Vasquez and C. Vidal and A. Wils},
  journal= {arXiv preprint arXiv:2403.13789},
  year   = {2024}
}

Comments

35 pages, 36 figures

R2 v1 2026-06-28T15:27:40.931Z