Related papers: The Kitt Peak Electron Multiplying CCD demonstrato…
The purpose of this project is to investigate the use of charge couple devices (CCDs) to detect electrons directly. This can be done in transmission electron microscopy (TEM) for electrons over 100 KeV, but for space plasma instruments,…
Photon counting is a mode of processing astronomical observations of low-signal targets that have been observed using an electron-multiplying charge-coupled device (EMCCD). In photon counting, the EMCCD amplifies the signal, and a…
The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise…
A prototype of digital frequency multiplexing electronics allowing the real time monitoring of microwave kinetic inductance detector (MKIDs) arrays for mm-wave astronomy has been developed. Thanks to the frequency multiplexing, it can…
Context. Millimetre-wave astronomy is an important tool for both general astrophysics studies and cosmology. A large number of unidentified sources are being detected by the large field-of-view continuum instruments operating on large…
Colossal two-phase Liquid Argon Time Projection Chambers (LAr TPCs) are a proposed option for future long-baseline neutrino experiments. This study illustrates the feasibility of using an EMCCD camera to capture light induced by single…
The Epoch of Reionization Spectrometer (EoR-Spec) will be an instrument module for the Prime-Cam receiver on the CCAT-prime Collaboration's Fred Young Submillimeter Telescope (FYST), a 6-m primary mirror Crossed Dragone telescope. With its…
In recent years, detectors with sub-electron readout noise have been used very effectively in astronomical adaptive optics systems. Here, we compare readout noise models for the two key faint flux level detector technologies that are…
Wearable sensing devices, such as Electrocardiogram (ECG) heart-rate monitors, will play a crucial role in the future of digital health. This continuous monitoring leads to massive unlabeled data, incentivizing the development of…
A new generation CCD detector called low light level CCD (L3CCD) that performs like an intensified CCD without incorporating a micro channel plate (MCP) for light amplification was procured and tested. A series of short exposure images with…
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time…
We describe a high speed time-series CCD photometer for the prime focus of the 82-in (2.1 m) telescope at McDonald Observatory, and summarize the observational results we have obtained since it was placed into regular use in February, 2002.…
Although the MeV gamma-ray band is a promising energy-band window in astrophysics, the current situation of MeV gamma-ray astronomy significantly lags behind those of the other energy bands in angular resolution and sensitivity. An…
A Semiconductor Multiple-Compton Telescope (SMCT) is being developed to explore the gamma-ray universe in an energy band 0.1--20 MeV, which is not well covered by the present or near-future gamma-ray telescopes. The key feature of the SMCT…
We report on the upgraded One Degree Imager (ODI) at the WIYN 3.5 meter telescope at the Kitt Peak Observatory after the focal plane was expanded by an additional seventeen detectors in spring 2015. The now thirty Orthogonal Transfer Array…
The EPIC pn CCD camera on board of XMM-Newton is designed to perform high throughput imaging and spectroscopy as well as high resolution timing observations in the energy range of 0.1-15 keV. A temporal resolution of milliseconds or…
Unlike most commercially available silicon photomultipliers (SiPMs), EQR20 SiPMs produced by the Novel Device Laboratory (NDL) avoid using individual resistors to quench the avalanche multiplication of the microcells. Instead, bulk…
Multichip modules (MCM) with 4 single photon counting MPEC 2.3 chips bump bonded to 1.3 cm x 1.3 cm large CdTe and Si semiconductor sensors as well as to single chip pixel detectors have been successfully built and operated. The MPEC 2.3…
Numerous applications at the photon-starved regime require a free-space coupling singlephoton detector with a large active area, low dark count rate (DCR), and superior time resolutions. Here,we developed a superconducting microstrip…
We introduce a new output amplifier for fully-depleted thick p-channel CCDs based on double-gate MOSFETs. The charge amplifier is an n-type MOSFET specifically designed and operated to couple the fully-depleted CCD with high charge-transfer…