Related papers: XRF element localization with a triple GEM detecto…
We briefly review the concept and properties of the Thick GEM (THGEM); it is a robust, high-gain gaseous electron multiplier, manufactured economically by standard printed-circuit drilling and etching technology. Its operation and structure…
We have developed a new design of a GEM-like detector with single-layer electrodes made of a resistive kapton. This detector can operate at gains close to 10E5 even in pure Ar and Ne and if transited to discharges at higher gains they, due…
Presented here are first tests of a Gaseous Photomultiplier based on a cascade of Thick GEM structures intended for gamma-ray position reconstruction in liquid Argon. The detector has a MgF$_2$ window, transparent to VUV light, and a CsI…
For its physics program with a high-intensity hadron beam of up to 2e7 particles/s, the COMPASS experiment at CERN requires tracking of charged particles scattered by very small angles with respect to the incident beam direction. While good…
An interpolating two-dimensional X-ray imaging detector based on a single photon counter with gas amplification by GEM (gas electron multiplier) structures is presented. The detector system can be used for time-resolved structure research…
The idea of implementing electroluminescence-based amplification through transparent multi-hole structures (FAT-GEMs) has been entertained for some time. Arguably, for such a technology to be attractive it should perform at least at a level…
We present results from our recent investigations on detectors comprising cascaded gas electron multipliers (GEM) and cascaded GEMs with micro-hole and strip (MHSP) electrodes. We discuss the factors governing the operation of these fast…
We study the performances of gaseous and two-phase (liquid-gas) cryogenic detectors of ionizing radiation based on gas electron multipliers (GEMs) and operated in an avalanche mode in pure noble gases. The gas amplification in He, Ar and Kr…
Thick GEM-like (THGEM) gaseous electron multipliers are made of standard printed-circuit board perforated with sub-millimeter diameter holes, etched at their rims. Effective gas multiplication factors of 100000 and 10000000 and fast pulses…
An innovative photosensitive gaseous detector, consisting of a GEM like amplification structure with double layered electrodes (instead of commonly used metallic ones) coated with a CsI reflective photocathode, is described. In one of our…
An approximate formula has been derived for gain fluctuations in cascaded gaseous detectors such as GEM-s, based on the assumption that the charge collection, avalanche formation and extraction steps are independent cascaded processes. In…
An x-ray detector using a liquid-helium cooled large-area silicon PIN photodiode has been developed along with a tailor-made charge sensitive preamplifier whose first-stage JFET has been cooled. The operating temperature of the JFET has…
We have operated a Medipix2 CMOS readout chip, with amplifying, shaping and charge discriminating front-end electronics integrated on the pixel-level, as a highly segmented direct charge collecting anode in a three-stage gas electron…
Triple-GEM detector technology was recently selected by CMS for a part of the upgrade of its forward muon detector system as GEM detectors provide a stable operation in the high radiation environment expected during the future…
The physics studies at heavy-ion nucleus-nucleus collision experiments demand reliable detectors at high particle flux. Therefore, Gas Electron Multipliers (GEM) detectors, which show resilience to extreme radiation, are one of the prime…
Most material discrimination in security inspections is based on dual-energy x-ray imaging, which enables the determination of a material's effective atomic number (Zeff) as well as electron density and its consequent classification as…
Micro-pattern gas detectors, such as the Gas Electron Multiplier (GEM) and the Micromegas need narrow high density anode readout elements to achieve good spatial resolution. A high-density anode readout would require an unmanageable number…
We investigate the gas gain behaviour of a triple-GEM configuration in gas mixtures of argon, krypton and xenon with ten and thirty percent of carbon dioxide at pressures between 1 and 3 bar. Since the signal widths affect the dead time…
We present design and construction of a large low-mass Triple-GEM detector prototype for forward tracking at a future Electron-Ion Collider. In this environment, multiple scattering of forward and backward tracks must be minimized so that…
The properties of thick GEM-like (TGEM) gaseous electron multipliers, operated at 1-740 Torr are presented. They are made of a G-10 plate, perforated with millimeter-scale diameter holes. In single-multiplier elements, effective gains of…