English
Related papers

Related papers: The GlueX Start Counter Detector

200 papers

The performance of the GlueX Forward Calorimeter was studied using a small version of the detector and a variable energy electron beam derived from the Hall B tagger at Jefferson Lab. For electron energies from 110 MeV to 260 MeV, which are…

The GlueX experiment at Jefferson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a…

Instrumentation and Detectors · Physics 2022-03-17 S. Adhikari , C. S. Akondi , H. Al Ghoul , A. Ali , M. Amaryan , E. G. Anassontzis , A. Austregesilo , F. Barbosa , J. Barlow , A. Barnes , E. Barriga , R. Barsotti , T. D. Beattie , J. Benesch , V. V. Berdnikov , G. Biallas , T. Black , W. Boeglin , P. Brindza , W. J. Briscoe , T. Britton , J. Brock , W. K. Brooks , B. E. Cannon , C. Carlin , D. S. Carman , T. Carstens , N. Cao , O. Chernyshov , E. Chudakov , S. Cole , O. Cortes , W. D. Crahen , V. Crede , M. M. Dalton , T. Daniels , A. Deur , C. Dickover , S. Dobbs , A. Dolgolenko , R. Dotel , M. Dugger , R. Dzhygadlo , A. Dzierba , H. Egiyan , T. Erbora , A. Ernst , P. Eugenio , C. Fanelli , S. Fegan , A. M. Foda , J. Foote , J. Frye , S. Furletov , L. Gan , A. Gasparian , A. Gerasimov , N. Gevorgyan , C. Gleason , K. Goetzen , A. Goncalves V. S. Goryachev , L. Guo , H. Hakobyan , A. Hamdi , J. Hardin , C. L. Henschel , G. M. Huber , C. Hutton , A. Hurley , P. Ioannou , D. G. Ireland , M. M. Ito , N. S. Jarvis , R. T. Jones , V. Kakoyan , S. Katsaganis , G. Kalicy , M. Kamel , C. D. Keith , F. J. Klein , R. Kliemt , D. Kolybaba , C. Kourkoumelis , S. T. Krueger , S. Kuleshov , I. Larin , D. Lawrence , J. P. Leckey , D. I. Lersch , B. D. Leverington , W. I. Levine , W. Li , B. Liu , K. Livingston , G. J. Lolos , V. Lyubovitskij , D. Mack , H. Marukyan , P. T. Mattione , V. Matveev , M. McCaughan , M. McCracken , W. McGinley , J. McIntyre , D. Meekins , R. Mendez , C. A. Meyer , R. Miskimen , R. E. Mitchell , F. Mokaya , K. Moriya , F. Nerling , L. Ng , H. Ni , A. I. Ostrovidov , Z. Papandreou , M. Patsyuk , C. Paudel , P. Pauli , R. Pedroni , L. Pentchev , K. J. Peters , W. Phelps , J. Pierce , E. Pooser , V. Popov , B. Pratt , Y. Qiang , N. Qin , V. Razmyslovich , J. Reinhold , B. G. Ritchie , J. Ritman , L. Robison , D. Romanov , C. Romero , C. Salgado , N. Sandoval , T. Satogata , A. M. Schertz , S. Schadmand , A. Schick , R. A. Schumacher , C. Schwarz , J. Schwiening , A. Yu. Semenov , I. A. Semenova , K. K. Seth , X. Shen , M. R. Shepherd , E. S. Smith , D. I. Sober , A. Somov , S. Somov , O. Soto , N. Sparks , M. J. Staib , C. Stanislav , J. R. Stevens , J. Stewart , I. I. Strakovsky , B. C. L. Summner , K. Suresh , V. V. Tarasov , S. Taylor , L. A. Teigrob , A. Teymurazyan , A. Thiel , I. Tolstukhin , A. Tomaradze , A. Toro , A. Tsaris , Y. Van Haarlem , G. Vasileiadis , I. Vega , G. Visser , G. Voulgaris , N. K. Walford , D. Werthmüller , T. Whitlatch , N. Wickramaarachchi , M. Williams , E. Wolin , T. Xiao , Y. Yang , J. Zarling , Z. Zhang , Q. Zhou , X. Zhou , B. Zihlmann

The electromagnetic barrel calorimeter is one of the main components of the planned GlueX experiment. It will consist of 48 modules made of consecutive layers of 4 m long lead sheet and fast green scintillator fibers for an overall number…

Instrumentation and Detectors · Physics 2009-11-13 M. Barbi

START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs…

The GlueX forward calorimeter is an array of 2800 lead glass modules that was constructed to detect photons produced in the decays of hadrons. A background to this process originates from hadronic interactions in the calorimeter, which, in…

Data Analysis, Statistics and Probability · Physics 2020-05-28 Rebecca Barsotti , Matthew R. Shepherd

The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two…

The paper describes the SPHINX facility which includes a wide-aperture magnetic spectrometer with scintillation counters and hodoscopes, proportional chambers and drift tubes, multichannel electromagnetic and hadron calorimeters, a guard…

The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II,is presented. The detector is based on several small plates of scintillator with a Silicon PhotoMultipliers dual-side readout. The optimisation of…

Instrumentation and Detectors · Physics 2015-06-18 M. De Gerone , F. Gatti , W. Ootani , Y. Uchiyama , M. Nishimura , S. Shirabe , P. W. Cattaneo , M. Rossella

The E864 experiment at BNL requires a beam counter and multiplicity detector system that can perform at an incident beam rate of 10^7 Au ions per second. We have developed and tested a 150 micrometer thick quartz Cherenkov beam counter and…

Instrumentation and Detectors · Physics 2009-10-31 P. Haridas , I. A. Pless , G. Van Buren , J. Tomasi , M. S. Z. Rabin , K. Barish , R. D. Majka

At high luminosity areas, beam loss monitor with fast response and high radiation resistance is crucial for accelerator operation. In this article, we report the design and test results of a fast response and radiation-resistant…

Instrumentation and Detectors · Physics 2023-03-01 Yuanjing Ji , Zebo Tang , Chen Li , Xin Li , Ming Shao

We present the timing characteristics of the flash ADC readout of the GlueX forward calorimeter, which depends on precise measurement of arrival time of pulses from FEU 84-3 photomultiplier tubes to suppress backgrounds. The tests presented…

Instrumentation and Detectors · Physics 2012-01-10 J. V. Bennett , M. Kornicer , M. R. Shepherd , M. M. Ito

In this work we present an elegant solution for a scintillation counter to be integrated into a cryogenic system. Its distinguishing feature is the absence of a continuous light guide coupling the scintillation and the photodetector parts,…

Instrumentation and Detectors · Physics 2015-03-17 A. Stoykov , R. Scheuermann , A. Amato , M. Bartkowiak , J. A. Konter , J. Rodriguez , K. Sedlak

The GlueX experiment at Jefferson Lab was specifically designed for precision studies of the light-meson spectrum. For this purpose, a photon beam with energies up to 12 GeV is directed onto a liquid hydrogen target contained within a…

High Energy Physics - Experiment · Physics 2023-10-23 Alexander Austregesilo

A semiconductor tracker for muon scattering tomography is presented. The tracker contains silicon strip sensors with an $80\,\mu$m pitch, precision mechanics and integrated cooling. The electronic readout of the sensors is performed by a…

Instrumentation and Detectors · Physics 2018-10-30 F. Keizer , A. Gorbatch , M. A. Parker , C. Steer , S. A. Wotton

A plastic scintillator bar with dimensions 300 cm x 2.5 cm x 11 cm was exposed to a focused muon beam to study its light yield and timing characteristics as a function of position and angle of incidence. The scintillating light was read out…

Instrumentation and Detectors · Physics 2017-08-07 A. Blondel , D. Breton , A. Dubreuil , A. Khotyantsev , A. Korzenev , J. Maalmi , A. Mefodev , P. Mermod , E. Noah

The gamma-ray detector AGILE, operating in the energy range from 30 MeV to 50 GeV, is composed by a tracking part, a light calorimeter and an anticoincidence system. Here we describe the detector and its capabilities to determine the…

The Central Drift Chamber is a straw-tube wire chamber of cylindrical structure located surrounding the target inside the bore of the GlueX spectrometer solenoid. Its purpose is to detect and track charged particles with momenta as low as…

High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have…

Instrumentation and Detectors · Physics 2014-10-17 Paolo W. Cattaneo , Matteo De Gerone , Flavio Gatti , Miki Nishimura , Wataru Ootani , Massimo Rossella , Yusuke Uchiyama

3D silicon pixel detectors have been investigated as radiation-hard candidates for the innermost layers of the HL-LHC upgrade of the ATLAS pixel detector. 3D detectors are already in use today in the ATLAS IBL and AFP experiments. These are…

A series of beam tests were conducted at the KEK AR test beamline in ordet to investigate the performance of a prototype detector for instrumentation in the low-E beamline at the CERN H2 line. For the silicon strip detector, the…

Instrumentation and Detectors · Physics 2025-05-27 Y. Hino , M. Harada , N. Meguro , T. Tada , Y. Koshio , K. Sakashita , M. Friend , T. Nakadaira , S. Nishimori , Y. Nagai
‹ Prev 1 2 3 10 Next ›