Related papers: Passive optical gyroscope with double homodyne rea…
A coherent, short-length reference arm reflectometer, which utilizes a 76-MHz repetition rate mode-locked fiber laser, was investigated experimentally for long fiber links (> 10 km). The reflectometer combines the advantages of optical…
The DECi-hertz Interferometer Gravitational wave Observatory (DECIGO) is designed to detect gravitational waves at frequencies between 0.1 and 10 Hz. In this frequency band, one of the most important science targets is the detection of…
Large Sagnac interferometers in the form of active ring lasers have emerged as unique rotation sensors in the geosciences, where their sensitivity allows to detect geodetic and seismological signals. The passive laser gyroscope variant,…
Cavities in large-scale photonic integrated circuits often suffer from a wider distribution of resonance frequencies due to fabrication errors. It is crucial to adjust the resonances of cavities using post-processing methods to minimize the…
High finesse Fabry-Perot(FP) cavity is a very important frequency reference for laser stabiliza- tion, and is widely used for applications such as precision measurement, laser cooling of ions or molecules. But the non-linear response of the…
Optical gyroscopes based on the Sagnac effect are the cornerstone of precision orientation and navigation. However, their bulky form factors prevent deployment in emerging mobile and autonomous systems. On nanophotonic platforms, the Sagnac…
Polariton lasing is demonstrated on the zero dimensional states of single GaAs/GaAlAs micropillar cavities. Under non resonant excitation, the measured polariton ground state occupancy is found to be as large as $10^{4}$. Changing the…
We present a scheme to strongly enhance the readout sensitivity of the squared displacement of a mobile scatterer placed in a Fabry-P\'erot cavity. We investigate the largely unexplored regime of cavity electrodynamics in which a highly…
A reduction of more than 20 dB of the intensity noise at the anti-phase relaxation oscillation frequency is experimentally demonstrated in a two-polarization dual-frequency solid-state laser without any optical or electronic feedback loop.…
We stabilize the idler frequency of a singly-resonant optical parametric oscillator directly to the resonance of a mid-infrared Fabry-P\'erot reference cavity. This is accomplished by the Pound-Drever-Hall locking scheme, controlling either…
Optical Fabry-Perot cavities always show a non-degeneracy of two orthogonal polarisation states. This is due to the unavoidable birefringence of dielectric mirrors whose effects are extremely important in Fabry-Perot based high-accuracy…
To obtain a high degree of long-term length stabilisation of an optical reference cavity, its free-spectral range is locked by means of an accurate and stable frequency synthesizer. The locking scheme is twofold: a laser is locked on the…
We introduce a laser heterodyne polarimeter designed for the precision measurement of sub $\mu\mathrm{rad}$ differential phase shifts due to birefringence. The polarimeter will be used in an initial testbed for a potential future vacuum…
Measuring low light absorption with combined uncertainty < 1 permille is crucial in a wide range of applications. Popular cavity ring-down spectroscopy can provide ultra-high precision, below 0.01 permille, but its accuracy is strongly…
Possible light bosonic dark matter interactions with the Standard Model photon have been searched by microwave resonant cavities. In this paper, we demonstrate the cryogenic readout system calibration of a 7.138 GHz copper cavity with a…
We describe a simple method for measuring the residual fast phase noise of a cavity-stabilized laser using the cavity as a reference. The method is based on generating a beat note between the laser output and the strongly filtered light…
We present two ultra-stable lasers based on two vibration insensitive cavity designs, one with vertical optical axis geometry, the other horizontal. Ultra-stable cavities are constructed with fused silica mirror substrates, shown to…
We stabilized the frequencies of two independent Nd:YAG lasers to two adjacent longitudinal modes of a high-finesse Fabry-P\'erot resonator and obtained a beat frequency instability of 6.3 mHz at an integration time of 40 s. Referred to a…
Earth-based gravitational-wave detectors will be limited by quantum noise in a large part of their spectrum. The most promising technique to achieve a broadband reduction of such noise is the injection of a frequency dependent squeezed…