Segmentation of retinal layers from Optical Coherence Tomography (OCT) volumes is a fundamental problem for any computer aided diagnostic algorithm development. This requires preprocessing steps such as denoising, region of interest…

Computer Vision and Pattern Recognition · Computer Science 2018-06-26 Karthik Gopinath , Samrudhdhi B Rangrej , Jayanthi Sivaswamy

Optical coherence tomography (OCT) helps ophthalmologists assess macular edema, accumulation of fluids, and lesions at microscopic resolution. Quantification of retinal fluids is necessary for OCT-guided treatment management, which relies…

Image and Video Processing · Electrical Eng. & Systems 2022-12-15 Reza Rasti , Armin Biglari , Mohammad Rezapourian , Ziyun Yang , Sina Farsiu

Acute lymphoblastic leukemia (ALL) is a form of blood cancer that affects the white blood cells. ALL constitutes approximately 25% of pediatric cancers. Early diagnosis and treatment of ALL are crucial for improving patient outcomes. The…

Image and Video Processing · Electrical Eng. & Systems 2024-07-16 Dimitris Papaioannou , Ioannis Christou , Nikos Anagnou , Aristotelis Chatziioannou

Commercial iterative reconstruction techniques on modern CT scanners target radiation dose reduction but there are lingering concerns over their impact on image appearance and low contrast detectability. Recently, machine learning,…

Computer Vision and Pattern Recognition · Computer Science 2019-07-16 Hongming Shan , Atul Padole , Fatemeh Homayounieh , Uwe Kruger , Ruhani Doda Khera , Chayanin Nitiwarangkul , Mannudeep K. Kalra , Ge Wang

Retinal imaging has emerged as a powerful, non-invasive modality for detecting and quantifying biomarkers of systemic diseases-ranging from diabetes and hypertension to Alzheimer's disease and cardiovascular disorders but current insights…

Image and Video Processing · Electrical Eng. & Systems 2025-05-28 Tariq M Khan , Toufique Ahmed Soomro , Imran Razzak

The global burden of acute and chronic wounds presents a compelling case for enhancing wound classification methods, a vital step in diagnosing and determining optimal treatments. Recognizing this need, we introduce an innovative…

Computer Vision and Pattern Recognition · Computer Science 2023-08-25 Yash Patel , Tirth Shah , Mrinal Kanti Dhar , Taiyu Zhang , Jeffrey Niezgoda , Sandeep Gopalakrishnan , Zeyun Yu

In tomographic reconstruction, the image quality of the reconstructed images can be significantly degraded by defects in the measured two-dimensional (2D) raw image data. Despite the importance of screening defective 2D images for robust…

Image and Video Processing · Electrical Eng. & Systems 2019-10-29 Donghun Ryu , Youngju Jo , Jihyeong Yoo , Taean Chang , Daewoong Ahn , Young Seo Kim , Geon Kim , Hyun-seok Min , Yongkeun Park

Optical transmission spectroscopy is one method to understand brain tissue structural properties from brain tissue biopsy samples, yet manual interpretation is resource intensive and prone to inter observer variability. Deep convolutional…

Medical Physics · Physics 2025-05-20 Mohnish Sao , Mousa Alrubayan , Prabhakar Pradhan

Forecasting motion of a specific target object is a common problem for surgical interventions, e.g. for localization of a target region, guidance for surgical interventions, or motion compensation. Optical coherence tomography (OCT) is an…

Image and Video Processing · Electrical Eng. & Systems 2020-06-02 Marcel Bengs , Nils Gessert , Alexander Schlaefer

Circulating tumor cells (CTCs) are crucial biomarkers in liquid biopsy, offering a noninvasive tool for cancer patient management. However, their identification remains particularly challenging due to their limited number and heterogeneity.…

Image and Video Processing · Electrical Eng. & Systems 2025-11-24 Martina Russo , Giulia Bertolini , Vera Cappelletti , Cinzia De Marco , Serena Di Cosimo , Petra Paiè , Nadia Brancati

Typical optical coherence tomographic angiography (OCTA) acquisition areas on commercial devices are 3x3- or 6x6-mm. Compared to 3x3-mm angiograms with proper sampling density, 6x6-mm angiograms have significantly lower scan quality, with…

Image and Video Processing · Electrical Eng. & Systems 2020-06-11 Min Gao , Yukun Guo , Tristan T. Hormel , Jiande Sun , Thomas Hwang , Yali Jia

A neural-network (NN)-based method for high-speed, high-definition dynamic optical coherence tomography (DOCT) using full-field swept-source optical coherence microscopy (FF-SS-OCM) is demonstrated. FF-SS-OCM provides high-definition OCT…

Choroid is the vascular layer of the eye, which is directly related to the incidence and severity of many ocular diseases. Optical Coherence Tomography (OCT) is capable of imaging both the cross-sectional view of retina and choroid, but the…

Computer Vision and Pattern Recognition · Computer Science 2019-12-12 Huihong Zhang , Jianlong Yang , Kang Zhou , Zhenjie Chai , Jun Cheng , Shenghua Gao , Jiang Liu

Purpose: Middle ear infection is the most prevalent inflammatory disease, especially among the pediatric population. Current diagnostic methods are subjective and depend on visual cues from an otoscope, which is limited for otologists to…

Computer Vision and Pattern Recognition · Computer Science 2023-04-27 Peng Liu , Jonas Golde , Joseph Morgenstern , Sebastian Bodenstedt , Chenpan Li , Yujia Hu , Zhaoyu Chen , Edmund Koch , Marcus Neudert , Stefanie Speidel

Reliable automated analysis of Optical Coherence Tomography (OCT) imaging is crucial for diagnosing retinal disorders but faces a critical barrier: the need for expensive, labor-intensive expert annotations. Supervised deep learning models…

Computer Vision and Pattern Recognition · Computer Science 2026-04-27 Tania Haghighi , Sina Gholami , Hamed Tabkhi , Minhaj Nur Alam

Optical coherence tomography (OCT) is a powerful technology for rapid volumetric imaging in biomedicine. The bright field imaging approach of conventional OCT systems is based on the detection of directly backscattered light, thereby…

Unlabeled data is often abundant in the clinic, making machine learning methods based on semi-supervised learning a good match for this setting. Despite this, they are currently receiving relatively little attention in medical image…

Computer Vision and Pattern Recognition · Computer Science 2020-10-26 Valentyn Melnychuk , Evgeniy Faerman , Ilja Manakov , Thomas Seidl

Purpose: (1) To assess the performance of geometric deep learning (PointNet) in diagnosing glaucoma from a single optical coherence tomography (OCT) 3D scan of the optic nerve head (ONH); (2) To compare its performance to that obtained with…

Image and Video Processing · Electrical Eng. & Systems 2022-04-15 Alexandre H. Thiery , Fabian Braeu , Tin A. Tun , Tin Aung , Michael J. A. Girard

Segmentation of curvilinear structures is important in many applications, such as retinal blood vessel segmentation for early detection of vessel diseases and pavement crack segmentation for road condition evaluation and maintenance.…

Image and Video Processing · Electrical Eng. & Systems 2022-04-06 Tianyi Shi , Nicolas Boutry , Yongchao Xu , Thierry Géraud

A major cause of irreversible visual impairment is angle-closure glaucoma, which can be screened through imagery from Anterior Segment Optical Coherence Tomography (AS-OCT). Previous computational diagnostic techniques address this…

Computer Vision and Pattern Recognition · Computer Science 2018-09-11 Huazhu Fu , Yanwu Xu , Stephen Lin , Damon Wing Kee Wong , Baskaran Mani , Meenakshi Mahesh , Tin Aung , Jiang Liu