English
Related papers

Related papers: Precision Timing with the CMS MIP detector

200 papers

The CMS detector is one of the two general purpose experiments that will study the collisions produced by the Large Hadron Collider (LHC). The LHC is supposed to start its operation in 2007 at an instantaneous luminosity of 2 x 10^33 cm-2…

High Energy Physics - Experiment · Physics 2019-08-14 G. Bruno

The CMS pixel detector has been designed for a peak luminosity of 10^34cm-2s-1 and a total dose corresponding to 2 years of LHC operation at a radius of 4 cm from the interaction region. Parts of the pixel detector will have to be replaced…

Instrumentation and Detectors · Physics 2010-01-25 H. C. Kästli

The prospect of pileup induced backgrounds at the High Luminosity LHC (HL-LHC) has stimulated intense interest in technology for charged particle timing at high rates. In contrast to the role of timing for particle identification, which has…

Instrumentation and Detectors · Physics 2018-12-26 Sebastian White

The Large Hadron Collider is the world's largest and highest center-of-mass energy particle accelerator. During the Phase I operation it is expected that the LHC operated at a centre-of-mass energy of 13 TeV will deliver to the CMS…

High Energy Physics - Experiment · Physics 2018-08-30 Petr Mandrik

The installation of the High-Luminosity Large Hadron Collider (HL-LHC) presents unprecedented challenges to experiments like the Compact Muon Solenoid (CMS) in terms of event rate, integrated luminosity and therefore radiation exposures. To…

Instrumentation and Detectors · Physics 2020-08-26 Peter Paulitsch

The timing measurement of charged particles using silicon detector is widely used in synchrotron source as X-ray detectors, in time-of-flight mass spectrometer and especially in large collider experiment. To reduce the drastically event…

Instrumentation and Detectors · Physics 2020-01-01 Yuzhen Yang , Suyu Xiao , Yunyun Fan , Dejun Han , Zhijun Liang , Baohua Qi , Liaoshan Shi , Yuhang Tan , Xingan Zhang , Xin Shi

We present a readout chip prototype for future pixel detectors with timing capabilities. The prototype is intended for characterizing 4D pixel arrays with a pixel size of $100\times100~\mu \text{m}^2$, where the sensors are Low Gain…

Instrumentation and Detectors · Physics 2023-02-15 Matias Senger , Lea Caminada , Benjamin Kilminster , Anna Macchiolo , Beat Meier , Stephan Wiederkehr

In this White Paper for the 2021 Snowmass process, we discuss aspects of precision timing within electromagnetic and hadronic calorimeter systems for high-energy physics collider experiments. Areas of applications include particle…

We have developed particle detectors based on fused silica (quartz) Cherenkov radiators read out with micro-channel plate photomultipliers (MCP-PMTs) or silicon photomultipliers (SiPMs) for high precision timing (Sigma(t) about 10-15 ps).…

Instrumentation and Detectors · Physics 2015-06-05 M. G. Albrow , Heejong Kim , S. Los , E. Ramberg , A. Ronzhin , V. Samoylenko , H. Wenzel , A. Zatserklyaniy

The High-Luminosity LHC (HL-LHC) will usher in a new era in high-energy physics. The HL-LHC experimental conditions entail an instantaneous luminosity of up to $7.5 \times 10^{34}$ cm$^{-2}$ s$^{-1}$ and up to 200 simultaneous collisions…

High Energy Physics - Experiment · Physics 2022-11-17 Thiago R. F. P. Tomei

A novel photodetector based on a MCP-PMT vacuum tube with encapsulated CMOS ASIC has been tested at the CERN SPS high energy hadron beam, allowing single photon Cherenkov detection operating at 10$^4$ gain and with timing resolution of…

The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by…

Instrumentation and Detectors · Physics 2012-08-27 CMS Collaboration

The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also…

Instrumentation and Detectors · Physics 2022-05-25 M. Abbas , M. Abbrescia , H. Abdalla , A. Abdelalim , S. AbuZeid , A. Agapitos , A. Ahmad , A. Ahmed , W. Ahmed , C. Aimè , C. Aruta , I. Asghar , P. Aspell , C. Avila , J. Babbar , Y. Ban , R. Band , S. Bansal , L. Benussi , T. Beyrouthy , V. Bhatnagar , M. Bianco , S. Bianco , K. Black , L. Borgonovi , O. Bouhali , A. Braghieri , S. Braibant , S. D. Butalla , S. Calzaferri , M. Caponero , J. Carlson , F. Cassese , N. Cavallo , S. S. Chauhan , S. Colafranceschi , A. Colaleo , J. Collins , A. Conde Garcia , M. Dalchenko , A. De Iorio , G. De Lentdecker , D. Dell Olio , G. De Robertis , W. Dharmaratna , S. Dildick , B. Dorney , R. Erbacher , F. Fabozzi , F. Fallavollita , A. Ferraro , D. Fiorina , E. Fontanesi , M. Franco , C. Galloni , P. Giacomelli , S. Gigli , J. Gilmore , M. Gola , M. Gruchala , A. Gutierrez , T. Hakkarainen , J. Hauser , K. Hoepfner , M. Hohlmann , H. Hoorani , T. Huang , P. Iaydjiev , A. Irshad , A. Iorio , F. Ivone , W. Jang , J. Jaramillo , A. Juodagalvis , E. Juska , B. Kailasapathy , T. Kamon , Y. Kang , P. Karchin , A. Kaur , H. Kaur , H. Keller , H. Kim , J. Kim , S. Kim , B. Ko , A. Kumar , S. Kumar , N. Lacalamita , J. S. H. Lee , A. Levin , Q. Li , F. Licciulli , L. Lista , K. Liyanage , F. Loddo , M. Luhach , M. Maggi , Y. Maghrbi , N. Majumdar , K. Malagalage , S. Malhotra , S. Martiradonna , C. McLean , J. Merlin , M. Misheva , G. Mocellin , L. Moureaux , A. Muhammad , S. Muhammad , S. Mukhopadhyay , M. Naimuddin , S. Nuzzo , R. Oliveira , P. Paolucci , I. C. Park , L. Passamonti , G. Passeggio , A. Peck , A. Pellecchia , N. Perera , L. Petre , H. Petrow , D. Piccolo , D. Pierluigi , M. Rahmani , F. Ramirez , A. Ranieri , G. Rashevski , B. Regnery , M. Ressegotti , C. Riccardi , M. Rodozov , E. Romano , C. Roskas , B. Rossi , P. Rout , J. D. Ruiz , A. Russo , A. Safonov , A. K. Sahota , D. Saltzberg , G. Saviano , A. Shah , A. Sharma , R. Sharma , T. Sheokand , M. Shopova , F. M. Simone , J. Singh , U. Sonnadara , A. Stamerra , E. Starling , B. Stone , J. Sturdy , G. Sultanov , Z. Szillasi , D. Teague , D. Teyssier , T. Tuuva , M. Tytgat , I. Vai , N. Vanegas , R. Venditti , P. Verwilligen , W. Vetens , A. K. Virdi , P. Vitulo , A. Wajid , D. Wang , K. Wang , I. J. Watson , N. Wickramage , D. D. C. Wickramarathna , S. Yang , U. Yang , Y. Yang , J. Yongho , I. Yoon , Z. You , I. Yu , S. Zaleski

Between 2025 and 2027, some essential components of the CMS (Compact Muon Solenoid) detector - most notably the tracker and the calorimeter endcap - will be upgraded to prepare for HL-LHC (High Luminosity Large Hadron Collider) conditions.…

Instrumentation and Detectors · Physics 2020-03-26 Viktoria Hinger

Operating the CMS Level-1 trigger under the intense conditions of the High-Luminosity Large Hadron Collider -- with approximately 63~Tb/s of input and a fixed 12.5~$\mu$s latency -- poses a demanding real-time reconstruction challenge. The…

High Energy Physics - Experiment · Physics 2025-09-30 Pelayo Leguina , Santiago Folgueras , Andrea Cardini , Elena Aller

The instantaneous luminosity of the Large Hadron Collider at CERN will be increased by up to a factor of five to seven with respect to the design value. To maintain an excellent detection and background rejection capability in the forward…

Instrumentation and Detectors · Physics 2018-10-03 Benoit Lefebvre

During the high-luminosity phase of the LHC (HL-LHC), planned to start around 2027, the accelerator is expected to deliver an instantaneous peak luminosity of up to $7.5\times10^{34}$ cm$^{-2}$s$^{-1}$. A total integrated luminosity of…

Instrumentation and Detectors · Physics 2020-06-17 The Tracker Group of the CMS Collaboration

The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The…