Related papers: Optical clock comparison test of Lorentz symmetry
For the purpose of searching for Lorentz-invariance violation in the minimal Standard-Model Extension, we perfom a reanalysis of data obtained from the $^{133}\text{Cs}$ fountain clock operating at SYRTE. The previous study led to new…
We study a wide range of neutral atoms and ions suitable for ultra-precise atomic optical clocks with naturally suppressed black body radiation shift of clock transition frequency. Calculations show that scalar polarizabilities of clock…
The cosmological applications of atomic clocks so far have been limited to searches of the uniform-in-time drift of fundamental constants. In this paper, we point out that a transient in time change of fundamental constants can be induced…
As a basic symmetry of space-time, Lorentz symmetry has played important roles in various fields of physics, and it is a glamorous question whether Lorentz symmetry breaks. Since Einstein proposed special relativity, Lorentz symmetry has…
We present the first experimental test of Lorentz invariance using the frequency difference between counter-propagating modes in an asymmetric odd-parity optical resonator. This type of test is $\sim10^{4}$ more sensitive to odd-parity and…
Optical atomic clocks promise timekeeping at the highest precision and accuracy, owing to their high operating frequencies. Rigorous evaluations of these clocks require direct comparisons between them. We have realized a high-performance…
We report a frequency measurement of the 1S0-3P0 transition of 87Sr atoms in an optical lattice clock. The frequency is determined to be 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical…
Lorentz symmetry is the fundamental symmetry of Einstein's theory of Special Relativity and has been tested to great precision. Nevertheless, the possibility remains that it is violated at the Planck scale, as predicted by some theories of…
We explore the limits of atomic coherence and measurement precision in a 87Sr optical lattice clock. We perform a detailed characterization of key effects, including lattice Raman scattering and atomic collisions in a shallow lattice…
We report a single-ion optical atomic clock with fractional frequency uncertainty of $5.5\times10^{-19}$ and fractional frequency stability of $3.5 \times10^{-16}/\sqrt{\tau/\mathrm{s}}$, based on quantum logic spectroscopy of a single…
A quantum clock must satisfy two basic constraints. The first is a bound on the time resolution of the clock given by the difference between its maximum and minimum energy eigenvalues. The second follows from Holevo's bound on how much…
Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may…
We survey the role of stable clocks in general relativity. Clock comparisons have provided important tests of the Einstein Equivalence Principle, which underlies metric gravity. These include tests of the isotropy of clock comparisons…
We present a theoretical analysis of signals for CPT and Lorentz violation in g-2 and charge-to-mass-ratio experiments on electrons and positrons in Penning traps. Experiments measuring anomaly frequencies are found to be the most sensitive…
High-precision measurements of violations of fundamental symmetries in atoms are a very effective means of testing the standard model of elementary particles and searching for new physics beyond it. Such studies complement measurements at…
Recent advances in optical atomic clocks and optical time transfer have enabled new possibilities in precision metrology for both tests of fundamental physics and timing applications. Here we describe a space mission concept that would…
Optical atomic clocks are poised to redefine the SI second, thanks to stability and accuracy more than one hundred times better than the current microwave atomic clock standard. However, the best optical clocks have not seen their…
A hypothetical violation of Lorentz invariance in the electrons' equation of motion (expressed within the Lorentz-violating extension of the standard model) leads to a change of the geometry of crystals and thus shifts the resonance…
Optical clock network requires the establishment of optical frequency transmission link between multiple optical clocks, utilizing narrow linewidth lasers. Despite achieving link noise levels of 10${^{-20}}$, the final accuracy is limited…
We report a comprehensive evaluation of all known sources of systematic uncertainty for two independent $^{176}$Lu$^+$ single-ion optical references, finding total systematic uncertainty of $1.1\times10^{-19}$ and $1.4\times10^{-19}$ for…