Related papers: A method to optimize patient specific HU-SP calibr…

200 papers

Objective. Proton beams enable localized dose delivery. Accurate range estimation is essential, but planning still relies on X-ray CT, which introduces uncertainty in stopping power and range. Proton CT measures water equivalent thickness…

Medical Physics · Physics 2025-09-15 Atiq Ur Rahman , Chun-Chieh Wang , Shu-Wei Wu , Tsi-Chian Chao , I-Chun Cho

In this work, we proposed virtual imaging simulators as an alternative approach to experimental validation of beam range uncertainty in complex patient geometry using a computational model of a human head and a photon-counting CT scanner.…

Medical Physics · Physics 2026-01-05 S. Vrbaški , G. Stanić , S. Molinelli , M. Bhattarai , E. Abadi , M. Ciocca , E. Samei

Background: Upright proton therapy with compact delivery systems has the potential to reduce costs for treatments but could also lead to broadening of the beam penumbra due to energy selection close to the patient. Purpose: This study aims…

Medical Physics · Physics 2025-08-22 Erik Engwall , Victor Mikhalev , Johan Sundström , Otte Marthin , Viktor Wase

To improve the quality of cancer treatment with protons, a translation of X-ray Computed Tomography (CT) images into a map of the proton stopping powers needs to be more accurate. Proton stopping powers determined from CT images have…

Proton Computed Tomography (pCT) provides a promising solution to enhance the accuracy of Relative Stopping Power (RSP) required for proton therapy planning. This research introduces a novel high-granularity pCT architecture that…

Verification of patient specific proton stopping powers obtained in the patient treatment position can be used to reduce the distal margins needed in particle beam planning. Proton radiography can be used as a pre-treatment instrument to…

Range uncertainties in proton therapy hamper treatment precision. Prompt gamma-rays were suggested 16 years ago for real-time range verification, and have already shown promising results in clinical studies with collimated cameras.…

Medical Physics · Physics 2021-12-07 F. Hueso-González , T. Bortfeld

Radiotherapy is one of the main methods in the successful treatment of cancer. The tumor is irradiated with photons or charged particles (e.g. protons), and in the case of massive charged particles, the treatment results in less unnecessary…

Medical Physics · Physics 2019-03-20 Monika Varga-Kofarago

Proton radiography combined with X-ray computed tomography (CT) has been proposed to obtain a patient-specific calibration curve and reduce range uncertainties in cancer treatment with charged particles. The main aim of this study was to…

Purpose: To evaluate reliability of upright CT for proton dose calculation and feasibility of a simplified phantom configuration for accelerated routine QA. Methods: A calibration phantom was scanned on an upright CT following consensus…

Uncertainties in the proton range in tissue during proton therapy limit the precision in treatment delivery. These uncertainties result in expanded treatment margins, thereby increasing radiation dose to healthy tissue. Real-time range…

Medical Physics · Physics 2018-10-17 Kristian Smeland Ytre-Hauge , Kyrre Skjerdal , John Mattingly , Ilker Meric

Purpose: Currently, calculations of proton range in proton therapy patients are based on a conversion of CT Hounsfield Units of patient tissues into proton relative stopping power. Uncertainties in this conversion necessitate larger…

Treatment planning uncertainties are typically managed using margin-based or robust optimization. Margin-based methods expand the clinical target volume (CTV) to a planning target volume, generally unsuited for proton therapy. Robust…

The design, construction, and preliminary testing of a second generation proton CT scanner is presented. All current treatment planning systems at proton therapy centers use X-ray CT as the primary imaging modality for treatment planning to…

Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stopping power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stopping power in tissue…

Proton computed tomography (pCT) is a novel medical imaging modality for mapping the distribution of proton relative stopping power (RSP) in medical objects of interest. Compared to conventional X-ray computed tomography, where range…

Purpose: To characterize image quality, imaging dose, and dose calculation accuracy for an upright CT scanner with a six-degree-of-freedom patient positioning system. Methods: Imaging dose (CTDIvol) was measured at 120 kVp and 200 mAs.…

Purpose: To improve target coverage and reduce the dose in the surrounding organs-at-risks (OARs), we developed an image-guided treatment method based on a precomputed library of treatment plans controlled and delivered in real-time.…

Medical Physics · Physics 2022-11-02 Valentin Hamaide , Kevin Souris , Damien Dasnoy , Francois Glineur , Benoit Macq

Purpose: A promising approach to enable FLASH conformal proton therapy is to passively degrade a single energy layer using a patient-specific range modulator. We propose an innovative method to directly optimize the geometrical…

Medical Physics · Physics 2023-03-16 Sylvain Deffet , Kevin Souris , Edmond Sterpin

Technical Note describing studies, in 2011, of time resolved diode dosimetry in an anthropomorphic phantom at the Francis H. Burr Proton Therapy Center, Massachusetts General Hospital, Boston, MA. This technique measures the water…

Medical Physics · Physics 2014-07-14 Bernard Gottschalk