Related papers: Exploring a new ammeter traceability route for ion…
Ionization chambers are essential for activity determinations in radionuclide metrology. We have developed a high-precision integrating-differentiating (int-diff) system for measuring small currents. It is anticipated to enhance the…
New technology, the ultrastable low-noise current amplifier and the electron pump, provide new methods for making traceable measurements of small DC electric currents. We review four traceability routes for small current measurements and…
Air-ionization chambers have been used in radiotherapy and particle therapy for decades. However, fundamental parameters in action in the detector responses are sparsely studied. In this work we aimed to measure the electronic attachment,…
Accurate measurements of alternating current (AC) and direct current(DC) ratios are fundamental to electric power metrology. However, conventional current comparators for AC and DC typically rely on distinct technologies-electromagnetic…
A programmable quantum current generator based on the application of Ohm's law to quantum voltage and resistance standards has demonstrated a realization of the ampere from the elementary charge with a $10^{-8}$ relative uncertainty [J.…
We performed calibrations of four different commercial picoammeters using the Ultrastable Low-noise Current Amplifier (ULCA) as a calibrator current source operated in the range between 1 femtoampere and 1 microampere. The results allow the…
A standard method for picoammeter calibrations is the capacitor charging technique, which allows generating traceable currents in the sub-nA range. However, its accuracy is limited by the ac-dc differences of the capacitances involved. The…
An AC susceptometer operating in the range of 10 Hz to 100 kHz and at room temperature is designed, built, calibrated and used to characterize the magnetic behaviour of coated magnetic nanoparticles. Other weakly magnetic materials (in…
The detectors in mass spectrometers are precise enough to count ion events. In practice, the statistics of chemical noise are affected by large quantization errors and overdispersion because of amplification in the detector. The detector…
A new cryogenic noise calibration source for radio astronomy receivers is presented. Dissipated power is only 4.2 mW, allowing it to be integrated with the cold part of the receiver. Measured long-term stability, sensitivity to bias…
Electron counting experiments attempt to provide a current of a known number of electrons per unit time. We propose architectures utilizing a few readily available electron-pumps or turnstiles with the typical error rates of 100 ppm with…
Various applications of quantum devices call for an accurate calibration of cryogenic amplification chains. To this end, we present a convenient calibration scheme and use it to accurately measure the total gain and noise temperature of an…
We present the theoretical model of the "quantum ammeter", a device that is able to measure the full counting statistics of an electron current at quantum time scales. It consists of an Ohmic contact, perfectly coupled to chiral quantum…
Radiometer experiments to detect 21-cm Hydrogen line emission from the Cosmic Dawn and Epoch of Reionization rely upon precise absolute calibration. During calibration, noise generated by amplifiers within the radiometer receiver must be…
Consider an electron drifting in a gas toward a collection electrode. A common misconception is that the electron produces a detectable signal only upon arrival at the electrode. In fact, the situation is quite the opposite. The electron…
A method of electronic conductivity measurement is presented. It combines two well known methods of electrochemistry: cyclic voltammetry and chronoamperometry. This DC technique uses the Hebb/Wagner approach to block ionic conduction when…
Performing imperfect or noisy measurements on a quantum system both impacts the measurement outcome and the state of the system after the measurement. In this paper we are concerned with imperfect calorimetric measurements. In calorimetric…
A fast-reading current integrator is developed for high time-resolution and low-noise ion beam diagnostics under both continuous-wave and pulsed operating conditions. The system combines a low-leakage transimpedance front-end with a hybrid…
We analyze the phase-noise measurement methods in which correlation and averaging is used to reject the background noise of the instrument. All the known methods make use of a mixer, used either as a saturated phase detector or as a linear…
Bioimpedance measurements are a non-invasive method to determine the composition of organic tissue. For measuring the complex bioimpedance between two electrodes, an alternating current with a constant amplitude is injected into the tissue.…