Related papers: Development and Characterization of 6-gap Bakelite…

200 papers

The low cost and high resolution Multi-gap Resistive Plate Chamber (MRPC) opens up a new possibility to find an efficient alternative detector for the Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…

Instrumentation and Detectors · Physics 2015-06-22 A. Banerjee , A. Roy , S. Biswas , S. Chattopadhyay , G. Das , S. Pal

The Multigap Resistive Plate Chambers (MRPCs) are gas ionization detectors with multiple gas sub-gaps made of resistive electrodes. The high voltage (HV) is applied on the outer surfaces of outermost resistive plates only, while the…

Instrumentation and Detectors · Physics 2016-12-16 Moon Moon Devi , Naba K. Mondal , B. Satyanarayana , R. R. Shinde

A new kind of Multi-gap Resistive Plate Chamber (MRPC) has been built for the large-area Muon Telescope Detector (MTD) for the STAR experiment at RHIC. These long read-out strip MRPCs (LMRPCs) have an active area of 87.0 x 17.0 cm2 and ten…

The Multigap Resistive Plate Chambers (MRPCs) provide excellent timing as well as position resolutions at relatively low cost. Therefore, they can be used in medical imaging applications such as PET where precise timing is a crucial…

Instrumentation and Detectors · Physics 2019-07-23 M. Nizam , B. Satyanarayana , R. R. Shinde , G. Majumder

The Multigap Resistive Plate Chamber (MRPC) is a gaseous detector; the performance depends very much on the gas mixture as well as the design. MRPCs are used as a timing device in several collider experiments and cosmic ray experiments…

Instrumentation and Detectors · Physics 2019-03-27 Yongwook Baek , Dowon Kim , M. C. S. Williams

The low cost and high resolution gas-based Multi-gap Resistive Plate Chamber (MRPC) opens a new possibility to find an efficient alternative detector for Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the…

Instrumentation and Detectors · Physics 2011-06-30 A. Banerjee , S. Chattopadhyay

Resistive Plate Chambers (RPCs) featuring 1 mm gas volumes combined with high-pressure phenolic laminate (HPL) electrodes provide excellent timing resolution down to a few hundred picoseconds, along with spatial resolution on the order of a…

Resistive Plate Chamber (RPC) is a well-known gaseous detector in the field of High Energy Physics (HEP) experiments for its good tracking capability, high efficiency, good time resolution, and low cost of fabrication. The main issue in RPC…

Instrumentation and Detectors · Physics 2024-01-25 A. Sen , S. Chatterjee , S. Das , S. Biswas

A new prototype of large area Multi-gap Resistive Plate Chamber (MRPC) with long readout strips was built. This Long-strip Multi-gap Resistive Plate Chamber (LMRPC) is double stacked and has ten 250 $\mu$m-thick gas gaps. Signals are read…

Instrumentation and Detectors · Physics 2015-05-20 Yongjie sun , Cheng Li , Zebo Tang , Lailin Xu , Tianxiang Chen , Ming Shao

The Multigap Resistive Plate Chambers (MRPC) are used as a timing detector in several particle physics and cosmic ray experiments. The gas mixture of MRPC at current experiments is a mixture containing $\rm C_2F_4H_2$ and in some cases $\rm…

Instrumentation and Detectors · Physics 2020-01-29 Baek Yongwook , Kim Do-won , Park Woosung , Williams Crispin , Zuyeuski Roman

A prototype of Multi-strip Multi-gap Resistive Plate chamber (MMRPC) with active area 40 cm $\times$ 20 cm has been developed at SINP, Kolkata. Detailed response of the developed detector was studied with the pulsed electron beam from ELBE…

Resistive Plate Chamber (RPC) is a type of gaseous detector having excellent time and position resolutions. VECC is involved in the R\&D of indigenously developed bakelite RPCs. The largest size of bakelite RPC developed in India is 100 cm…

Instrumentation and Detectors · Physics 2016-03-17 R. Ganai , K. Agarwal , A. Roy , B. Muduli , S. Chattopadhyay , Z. Ahammed , G. Das , S. Ramnarayan

Resistive Plate Chamber (RPC) is one of the most commonly used detectors in high energy physics experiments for triggering and tracking because of its good efficiency ($\textgreater$~90\%) and time resolution ($\sim$~1-2~ns). Generally,…

Instrumentation and Detectors · Physics 2025-03-21 A. Sen , S. Mandal , S. Chatterjee , S. Gope , S. Das , S. Biswas

Single gap (gas gap 2 mm) bakelite Resistive Plate Chamber (RPC) modules of various sizes from 10 cm \times 10 cm to 1 m \times 1 m have been fabricated, characterized and optimized for efficiency and time resolution. Thin layers of…

Instrumentation and Detectors · Physics 2015-06-05 K. K. Meghna , A. Banerjee , S. Biswas , S. Bhattacharya , S. Bose , S. Chattopadhyay , G. Das , C. Marick , S. Saha , Y. P. Viyogi

A novel Resistive Plate Chamber (RPC) was designed with Diamond-Like Carbon (DLC) electrodes and performance studies were carried out for 384$\,\mathrm{\mu m}$ gap configuration with a $2\,\mathrm{cm}\times2\,\mathrm{cm}$ prototype. The use…

Instrumentation and Detectors · Physics 2024-01-25 Kei Ieki , Weiyuan Li , Atsuhiko Ochi , Rina Onda , Wataru Ootani , Atsushi Oya , Masato Takahashi , Kensuke Yamamoto

Resistive Plate Chamber (RPC) is a gaseous detector, known for its good spatial resolution and excellent time resolution. Due to its fast response and excellent time resolution, it is used for both triggering and timing purpose. But the…

Instrumentation and Detectors · Physics 2022-10-26 Jaydeep Datta , Nayana Majumdar , Supratik Mukhopadhyay , Sandip Sarkar

In order to test the performance of detector/prototype in environment of laboratory, we design and build a larger area ($90\times52$ $cm^2$) test platform of cosmic ray based on well-designed Multi-gap Resistive Plate Chamber (MRPC) with an…

Instrumentation and Detectors · Physics 2015-03-16 Tianxiang Chen , Cheng Li , Yongjie Sun , Hongfang Chen , Ming Shao , Zebo Tang , Rongxing Yang , Yi Zhou , Yifei Zhang

The time resolution of Multigap Resistive Plate Counters (MRPCs) to $511$ keV gamma rays has been investigated using a $^{22}$Na source and four detectors. The MRPCs time resolution has been derived from the Time-of-Flight information,…

Instrumentation and Detectors · Physics 2015-12-09 G. Belli , M. Gabusi , G. Musitelli , R. Nardò , S. P. Ratti , A. Tamborini , P. Vitulo

The detailed simulation of the Multi-gap Resistive Plate Chambers (MRPCs) provides the performance characteristics of MRPCs with different numbers of gas gaps and gap thicknesses. This helps in optimizing the structure of MRPCs under…

Instrumentation and Detectors · Physics 2024-12-31 J. Liu , Z. Chen , Y. Wang , B. Guo , D. Han , Y. Li

Single gap Resistive Plate Chamber (RPC) is one of the very popular gaseous detectors used in high-energy physics experiments nowadays. It is a very fast detector having low cost of fabrication. The RPCs are usually built using glass or…

Instrumentation and Detectors · Physics 2024-01-25 A. Sen , S. Chatterjee , S. Das , S. K. Ghosh , S. Biswas