English
Related papers

Related papers: Study on Timing Performance of a Readout Circuit f…

200 papers

The detector of TRopIcal DEep-sea Neutrino Telescope (TRIDENT) will use large-area silicon photomultiplier (SiPM) arrays combined with photomultiplier tubes to boost photon detection efficiency and pointing capability. An…

Instrumentation and Detectors · Physics 2025-02-06 M. X. Wang , Y. Liu , Y. Q. Tan , J. N. Tang , W. H. Wu , D. L. Xu , W. Zhi , Z. Z. Zhou

This paper describes the characterization of crystal matrices and silicon photomultiplier arrays for a novel Positron Emission Tomography (PET) detector, namely the external plate of the EndoTOFPET-US system. The EndoTOFPET-US collaboration…

Aiming to measure the difference in arrival times of two coincident gamma-photons with an accuracy in the order of 200 ps, time-of-flight positron emission tomography systems commonly employ silicon photomultipliers (SiPMs) and…

Medical Physics · Physics 2021-02-11 Vanessa Nadig , David Schug , Bjoern Weissler , Volkmar Schulz

Most detector systems used for positron emission particle tracking (PEPT) are very expensive due to the use of inorganic plastic scintillators combined with a high number of readout electronic channels. This work aims to reduce the overall…

Coincidence time resolution (CTR) in time-of-flight positron emission tomography (TOF-PET) has significantly improved with advancements in scintillators, photodetectors, and readout electronics. Achieving a CTR of 100 ps remains challenging…

Instrumentation and Detectors · Physics 2024-12-25 Yuya Onishi , Ryosuke Ota

The aim of this work is to show the potential capabilities of monolithic crystals coupled to large SiPM arrays, to be considered as detector blocks for PET scanners enabling Time Of Flight (TOF) capabilities. Monolithic blocks allow one to…

This work presents the 8-channel FastIC+, a low-power consumption and highly configurable multi-channel front-end ASIC with internal digitization, for the readout of photo-sensors with picosecond time resolution and intrinsic gain. This…

TRopIcal DEep-sea Neutrino Telescope (TRIDENT) plans to incorporate silicon photomultipliers (SiPMs) with superior time resolution in addition to photomultiplier tubes (PMTs) into its detection units, namely hybrid Digital Optical Modules…

Instrumentation and Detectors · Physics 2024-06-10 Wei Zhi , Ruike Cao , Jiannan Tang , Mingxin Wang , Yongqi Tan , Weihao Wu , Donglian Xu

In this study an array of eight 6 mm x 6 mm area SiPMs was coupled to the end of a long plastic scintillator counter which was exposed to a 2.5 GeV/c muon beam at the CERN PS. Timing characteristics of bars with dimensions 150 cm x 6 cm x 1…

Instrumentation and Detectors · Physics 2017-12-19 C. Betancourt , A. Blondel , R. Brundler , A. Datwyler , Y. Favre , D. Gascon , S. Gomez , A. Korzenev , P. Mermod , E. Noah , N. Serra , D. Sgalaberna , B. Storaci

The measurement of the time of flight of the two 511 keV gammas recorded in coincidence in a PET scanner provides an effective way of reducing the random background and therefore increases the scanner sensitivity, provided that the…

Instrumentation and Detectors · Physics 2016-10-12 J. J Gomez-Cadenas , J. M. Benlloch-Rodríguez , P. Ferrario , F. Monrabal , J. Rodríguez , J. F. Toledo

Plastic scintillator detectors have been extensively used in particle physics experiments for decades. A large-scale detector is typically arranged as an array of staggered long bars which provide a fast trigger signal and/or particle…

For a first characterization, we used the two KETEK-PM3325-WB SiPMs each equipped with a 3x3x5 mm${}^3$ LYSO scintillation crystal provided with the PETsys TOFPET2 ASIC Evaluation Kit. We changed the lower of two discriminator thresholds…

Instrumentation and Detectors · Physics 2018-12-05 David Schug , Vanessa Nadig , Bjoern Weissler , Pierre Gebhardt , Volkmar Schulz

Modern PET scanners based on scintillating crystals use solid state photo detectors for light readout. The small area of these devices is beneficial for spatial resolution, but also leads to a large number of electronic channels to be read…

Instrumentation and Detectors · Physics 2024-12-04 Peter Fischer , Michael Ritzert , Thomas Kerschenbauer

Positron Emission Tomography (PET) using time-of-flight information, which can greatly improve the quality of the reconstructed image, has recently become an exciting topic. In this work, 3.2mm*3.2mm*25mm finger-like LYSO crystals were used…

Instrumentation and Detectors · Physics 2015-07-17 Liu Jun-Hui , Xu Jiong-Hui , Cheng Feng-Feng , Li Dao-Wu , Zhang Zhi-Ming , Wang Bao-Yi , Wei Long

High-time-resolution counters based on plastic scintillator with silicon photomultiplier (SiPM) readout have been developed for applications to high energy physics experiments for which relatively large-sized counters are required. We have…

Instrumentation and Detectors · Physics 2014-10-17 Paolo W. Cattaneo , Matteo De Gerone , Flavio Gatti , Miki Nishimura , Wataru Ootani , Massimo Rossella , Yusuke Uchiyama

This paper presents the design, implementation, and performance evaluation of LUCAS, a low-power, ultra-low jitter ASIC optimized for SiPM readout in Time-of-Flight Computed Tomography (ToF-CT) applications. Leveraging a novel preamplifier…

Signal Processing · Electrical Eng. & Systems 2025-02-06 Seyed Arash Katourani

The signals received from the optical receivers like as SiPM and PMT due to the collision of energetic particles with the scintillators attached to these optical receivers, are weak and fast. To measure the number of signals as well as…

Instrumentation and Detectors · Physics 2022-10-04 Gholamreza Fardipour Raki , Maryam Ghahremani Gol , Mohammad Sahraei , Mohsen Khakzad

Silicon Photomultipliers (SiPMs) are photon-counting detectors with great potential to improve the sensitivity of optical receivers. Recent studies of SiPMs in communication focus on the speed rather than the power consumption of the…

Signal Processing · Electrical Eng. & Systems 2024-04-05 Yangchun Li , Danial Chitnis

The potential of photon detectors to achieve precise timing information is of increasing importance in many domains, PET and CT scanners in medical imaging and particle physics detectors, amongst others. The goal to increase by an order of…

Instrumentation and Detectors · Physics 2021-01-11 S. Enoch , A. Gola , P. Lecoq , A. Rivetti