Related papers: Dual-axis pi-pulse spin-exchange relaxation-free m…
In atomic magnetometers, the vector AC-Stark shift associated with circularly polarized light generates spatially varying effective magnetic fields which limit the magnetometer response and serve as sources of noise. We describe a scheme…
We propose a novel method to search for possible new macro-scale spin- and/or velocity-dependent forces (SVDFs) based on specially designed SmCo$_5$ spin sources and a spin exchange relaxation-free (SERF) comagnetometer. A simulation shows…
As a result of improvements in power semiconductors, moderate frequency switching supplies can now provide the hundreds of amps typically required by accelerators with zero-to-peak noise in the kHz region ~0.06% in current or voltage mode.…
This paper presents an optimized silicon-MEMS electromagnetic vibration energy harvester suitable for applications such as machine health monitoring. The harvester comprises a DRIE-etched silicon suspension, and pick-and-place N42 NdBFe…
We present the design process and implementation of fully open-source, ultra-low noise programmable current source systems in two configurations. Although originally designed as coil drivers for Optically Pumped Magnetometers (OPMs), the…
We discuss the design and performance of a laser-pumped cesium vapor magnetometer in the $M_x$-configuration. The device will be implemented for the control and stabilization of fluctuating magnetic fields and gradients in a new experiment…
We discuss multipulse magnetometry that exploits all three magnetic sublevels of the S=1 nitrogen-vacancy center in diamond to achieve enhanced magnetic field sensitivity. Based on dual frequency microwave pulsing, the scheme works in…
We report on investigation of spin Hall magnetoresistance sensor based on NiFe/AuxPt1-x bilayers. Compared to NiFe/Pt, the NiFe/AuxPt1-x sensor exhibits a much lower power consumption (reduced by about 57%), due to 80% enhancement of…
Magnetometers based on quantum mechanical processes enable high sensitivity and long-term stability without the need for re-calibration, but their integration into fieldable devices remains challenging. This paper presents a CMOS quantum…
We develop a theory of spin noise spectroscopy of itinerant, noninteracting, spin-carrying fermions in different regimes of temperature and disorder. We use kinetic equations for the density matrix in spin variables. We find a general…
We report the design and performance of a non-magnetic drift stable optically pumped cesium magnetometer with a measured sensitivity of 35 fT at 200 s integration time and stability below 50 fT between 70 s and 600 s. To our knowledge this…
In quantum sensing of magnetic fields, ensembles of nitrogen-vacancy centers in diamond offer high sensitivity, high bandwidth and outstanding spatial resolution while operating in harsh environments. Moreover, the orientation of defect…
For space-borne gravitational wave detectors,such as LISA and TianQin ,the disturbance caused by the coupling of test masses and the external magnetic fields is one of the main sources of the residual acceleration noise. Although the…
1/f noise is a critical figure of merit for the performance of transistors and circuits. For two-dimensional devices (2D-FETs), and especially for applications in the GHz range where short-channel FETs are required, velocity saturation (VS)…
The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system…
We describe a new approach to precision NMR with hyperpolarized gases designed to mitigate NMR frequency shifts due to the alkali spin exchange field. The electronic spin polarization of optically pumped alkali atoms is square-wave…
We report on compact, gaseous 3He NMR probes for precision magnetometry of magnetic fields B > 0.1 T in the temperature range from ambient temperatures down to 4 Kelvin. The gas is polarized at thermal equilibrium under pressures up to 100…
We demonstrate a precision magnetic microscope based on direct imaging of the Larmor precession of a $^{87}$Rb spinor Bose-Einstein condensate. This magnetometer attains a field sensitivity of 8.3 pT/Hz$^{1/2}$ over a measurement area of…
We reported a systematic study of spin-orbit torque biased magnetic sensors based on NiFe/Pt bilayers through both macro-spin modeling and experiments. The simulation results show that it is possible to achieve a linear sensor with a…
The nanometer scale beam sizes at the interaction point in linear colliders limit the allowable motion of the final focus magnets. We have constructed a prototype system to investigate the use of active vibration damping to control magnet…