English
Related papers

Related papers: Particle identification using digital pulse shape …

200 papers

Pulse-shape discrimination (PSD) is usually achieved using the different fast and slow decay components of inorganic scintillators, such as BaF2, CsI:Tl, etc. However, LaBr3:Ce is considered to not possess different components at room…

Instrumentation and Detectors · Physics 2021-09-03 Jirong Cang , XinChao Fang , Zhi Zeng , Ming Zeng , Yinong Liu , Zhigang Sun , Ziyun Chen

A comparative study of the neutron-$\gamma$ Pulse Shape Discrimination (PSD) with seven organic scintillators is performed using an identical setup and digital electronics. The scintillators include plastics (EJ-299-33 and a plastic…

Instrumentation and Detectors · Physics 2020-11-30 M. Sénoville , F. Delaunay , M. Pârlog , N. L. Achouri , N. A. Orr

Fast digitisers and digital pulse processing have been widely used for spectral application and pulse shape discrimination (PSD) owing to their advantages in terms of compactness, higher trigger rates, offline analysis, etc. Meanwhile, the…

Instrumentation and Detectors · Physics 2021-12-21 Jirong Cang , Tao Xue , Ming Zeng , Zhi Zeng , Hao Ma , Jianping Cheng , Yinong Liu

The proposed new Electron-Ion Collider poses a technical and intellectual challenge for the detector design to accommodate the long-term diverse physics goals envisaged by the program. This requires a 4{\pi} detector system capable of…

An ultra thin silicon detector called U3DTHIN has been designed and built for neutral particle analyzers (NPA) and thermal neutron detection. The main purpose of this detector is to provide a state-of-the-art solution for detector system of…

Instrumentation and Detectors · Physics 2018-01-03 F. Garcia , G. Pellegrini , M. Lozano , J. P. Balbuena , C. Fleta , C. Guardiola , D. Quirion

In a dedicated test setup at the Kamioka Observatory we studied pulse shape discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe was based on the observation that scintillation light from electron events was…

Neutron imaging is one of the most powerful tools for nondestructive inspection owing to the unique characteristics of neutron beams, such as high permeability for many heavy metals, high sensitivity for certain light elements, and isotope…

Charged Particle Therapy is a technique for cancer treatment that exploits hadron beams, mostly protons and carbons. A critical issue is the monitoring of the dose released by the beam to the tumor and to the surrounding tissues. We present…

The ATLAS Transition Radiation Tracker (TRT) is the outermost of the three sub-systems of the ATLAS Inner Detector at the Large Hadron Collider at CERN. In addition to its tracking capabilities, the TRT provides particle identification…

Instrumentation and Detectors · Physics 2019-08-13 E. Hines

Pulse shape discrimination with pure CsI scintillators is investigated as a method for separating energy deposits by energetic neutrons and photons at particle physics experiments. Using neutron data collected near the European XFEL XS1…

Instrumentation and Detectors · Physics 2022-07-11 S. Longo , M. Khan , S. Dharani , B. von Krosigk , T. Ferber

Hydrogenated amorphous silicon (a-Si:H) has remarkable radiation resistance properties and can be deposited on a lot of different substrates. A-Si:H based particle detectors have been built since mid 1980s as planar p-i-n or Schottky diode…

This paper proposes a high-precision time measurement method based on digital frequency-domain phase-fitting (DFPF) by using the digitized nuclear pulses. The averaging effect inherent in the frequency-domain cross-correlation and…

Instrumentation and Detectors · Physics 2025-04-17 Jianjun Wang , Zhaohui Bu , Zhao Wang , Jincheng Xu , Liguo Zhou , Qibin Zheng

Small-pitch 3D silicon pixel detectors have been investigated as radiation-hard candidates for the innermost layers of the HL-LHC pixel detector upgrades. Prototype 3D sensors with pixel sizes of 50$\times$50 and 25$\times$100 $\mu$m$^{2}$…

Instrumentation and Detectors · Physics 2018-09-18 J. Lange , G. Giannini , S. Grinstein , M. Manna , G. Pellegrini , D. Quirion , S. Terzo , D. Vázquez Furelos

A novel composite, scintillating material intended for neutron detection and composed of small (1.5 mm) cubes of KG2-type lithium glass embedded in a matrix of scintillating plastic has been developed in the form of a 2.2 in.-diameter, 3.1…

Instrumentation and Detectors · Physics 2015-05-27 G. C. Rich , K. Kazkaz , H. P. Martinez , T. Gushue

The electron density is a key parameter to characterize any plasma. Most of the plasma applications and research in the area of low-temperature plasmas (LTPs) are based on the accurate estimations of plasma density and plasma temperature.…

The present generation of Micro-Pattern Gaseous Detectors (MPGDs) are radiation hard detectors, capable of detecting efficiently particle rates of several MHz/cm$^2$ , while exhibiting good spatial resolution ($\leq$ 50 $\mu$m) and modest…

Inspired by Wilkinson ADC method, we implement a fast linear discharge method based on FPGA to digitize nuclear pulse signal. In this scheme, we use a constant current source to discharge the charge on capacitor which is integrated by the…

Instrumentation and Detectors · Physics 2018-06-08 Xiaoguang Kong , Yonggang Wang , Liwei Wang , Yong Xiao , Jie Kuang

Superheated drop detector (SDD) consisting of drops of superheated liquid of halocarbon is irradiated to neutrons and gamma-rays from 252Cf fission neutron source and 137Cs gamma source separately. The analysis of pulse height of the…

Instrumentation and Detectors · Physics 2014-11-21 Mala Das , S Seth , S Saha , S Bhattacharya , P Bhattacharjee

Conventional silicon photomultipliers (SiPMs) are well established as light detectors with single-photon-detection capability and used throughout high energy physics, medical, and commercial applications. The possibility to produce single…

A novel algorithm for the discrimination of neutron and {\gamma}-ray with wavelet transform modulus maximum (WTMM) in an organic scintillation has been investigated. Voltage pulses arising from a BC501A organic liquid scintillation detector…

Instrumentation and Detectors · Physics 2013-04-18 Yang yun , Liu guofu , Yang jun , Luo xiaoliang