Related papers: MultiSIMNRA: a computational tool for self-consist…
The PAMELA apparatus has been assembled and it is ready to be launched in a satellite mission to study mainly the antiparticle component of cosmic rays. In this paper the performances obtained for the silicon microstrip detectors used in…
The detection of 200-1000 MeV neutrons requires large amounts, $\sim$100 cm, of detector material because of the long nuclear interaction length of these particles. In the example of the NeuLAND neutron time-of-flight detector at FAIR, this…
Within the scope of the relativistic quantum theory for electron-laser interaction in a medium and using the resonant approximation for the two degenerated states of an electron in a monochromatic radiation field [1] a nonperturbative…
Computational multiscale modeling encompasses a wide range of end-products and a great number of technological applications. This paper provides an overview of the computational multiscale modeling approach based on the utilization of MBN…
Adoption of renewable energy is essential to address the challenge of climate change, but that necessitates energy storage technologies. Lithium-ion batteries, the most ubiquitous solution, are insufficient for large-scale applications, so…
As an application of the solution of the equations of electromagnetic self-consistency in a plasma, found in a previous paper, the study of controlled thermo-nuclear fusion is undertaken. This study utilizes the resonance which can be…
AIMS: Clinical radiographic imaging is seated upon the principle of differential keV photon transmission through an object. At clinical x-ray energies the scattering of photons causes signal noise and is utilized solely for transmission…
Many types of neutron spectrometer use a conventional primary spectrometer consisting of some collimator, a crystal monochromator and a second collimator. Conventional resolution descriptions use instrument parameter values to deduce the…
Medical synchrotrons are often used for testing instrumentation in high-energy physics or non-clinical research in medical physics. In many applications of medical synchrotrons, such as microdosimetry and ion imaging, precise knowledge of…
We propose a technique of compensating the spurious reflections implied by the multiple-scattering (MS) method, commonly used for analyzing finite photonic crystal (PC) systems, to obtain exact values of characteristic parameters, such as…
The ITER Vertical Neutron Camera (VNC) is a multichannel collimator system designed to measure the neutron emissivity profile and spectra. The energy spectrum measurements of neutrons made by the VNC will contribute to the reconstruction of…
We performed model calculations of Raman responses for multiband 2D superconductors. The multiband effects of screening in the A_{1g} symmetry channel were investigated analytically and numerically for a band structure model mimicing ARPES…
The possibility of generation of stable self-focusing beams in in-plane magnetized thin magnetic films is considered and theoretical conditions for the existence of such localized solutions are discussed. It is shown that for the definite…
We present a simplified model for dynamical diffraction of particles through a periodic thick perfect crystal based on repeated application of a coherent beam splitting unitary at coarse-grained lattice sites. By demanding translational…
Imaging surfaces using low energy neutral atom scattering is a relatively recent development in the field of microscopy. In this work we demonstrate that this technique is sensitive enough to distinguish films as thin as a single monolayer…
Sub-diffraction resolution, gentle sample illumination, and the possibility to image in multiple colors make Structured Illumination Microscopy (SIM) an imaging technique which is particularly well suited for live cell observations. Here,…
We present the Fortran code SIMLA, which is designed for the study of charged particle dynamics in laser and other background fields. This can be done classically via the Landau-Lifshitz equation, or alternatively, via the simulation of…
We present the experimental observation of the reduction of multiple scattering of high-energy positively charged particles during channeling in single crystals. According to our measurements the rms angle of multiple scattering in the…
Traditional image acquisition for cryo focused ion-beam scanning electron microscopy tomography often sees thousands of images being captured over a period of many hours, with immense data sets being produced. When imaging beam sensitive…
We examine x-ray scattering from an isolated organic molecule from the linear to nonlinear absorptiveregime. In the nonlinear regime, we explore the importance of both the elastic and inelastic channelsand observe the onset of nonlinear…