Related papers: Effects of Important Parameters Variations on Comp…
Ultrasound imaging, despite its widespread use in medicine, often suffers from various sources of noise and artifacts that impact the signal-to-noise ratio and overall image quality. Enhancing ultrasound images requires a delicate balance…
In Photoacoustic imaging, Delay-and-Sum (DAS) algorithm is the most commonly used beamformer. However, it leads to a low resolution and high level of sidelobes. Delay-Multiply-and-Sum (DMAS) was introduced to provide lower sidelobes…
Delay and Sum (DAS), as the most common beamforming algorithm in Photoacoustic Imaging (PAI), having a simple implementation, results in a low-quality image. Delay Multiply and Sum (DMAS) was introduced to improve the quality of the…
One of the common algorithms used to reconstruct photoacoustic (PA) images is the non-adaptive Delay-and-Sum (DAS) beamformer. However, the quality of the reconstructed PA images obtained by DAS is not satisfying due to its high level of…
Delay and sum (DAS) is the most common beamforming algorithm in linear-array photoacoustic imaging (PAI) as a result of its simple implementation. However, it leads to a low resolution and high sidelobes. Delay multiply and sum (DMAS) was…
Beamforming in ultrasound imaging has significant impact on the quality of the final image, controlling its resolution and contrast. Despite its low spatial resolution and contrast, delay-and-sum is still extensively used nowadays in…
Delay-and-Sum (DAS) is the most common algorithm used in photoacoustic (PA) image formation. However, this algorithm results in a reconstructed image with a wide mainlobe and high level of sidelobes. Minimum variance (MV), as an adaptive…
We propose a framework for extracting the bone surface from B-mode images employing the eigenspace minimum variance (ESMV) beamformer and a ridge detection method. We show that an ESMV beamformer with a rank-1 signal subspace can preserve…
Delay-and-Sum (DAS) beamformer is the most common beamforming algorithm in Photoacoustic imaging (PAI) due to its simple implementation and real time imaging. However, it provides poor resolution and high levels of sidelobe. A new algorithm…
Optical resolution photoacoustic microscopy (OR-PAM) leverages optical focusing and acoustic detection for microscopic optical absorption imaging. Intrinsically it owns high optical lateral resolution and poor acoustic axial resolution.…
Photoacoustic imaging (PAI) is an emerging biomedical imaging modality capable of providing both high contrast and high resolution of optical and UltraSound (US) imaging. When a short duration laser pulse illuminates the tissue as a target…
Inter-user interference (IUI) mitigation has been an essential issue for multi-user multiple-input multiple-output (MU-MIMO) communications. The commonly used linear processing schemes include the maximum-ratio combining (MRC), zero-forcing…
Sound speed heterogeneities can create aberrations in B-mode ultrasound images by inducing tissue-dependent delays and diffractive effects that conventional beamforming does not incorporate. By using the Fourier split-step method to…
Endmember (EM) variability has an important impact on the performance of hyperspectral image (HI) analysis algorithms. Recently, extended linear mixing models have been proposed to account for EM variability in the spectral unmixing (SU)…
In Photoacoustic imaging (PAI), the most prevalent beamforming algorithm is delay-and-sum (DAS) due to its simple implementation. However, it results in a low quality image affected by the high level of sidelobes. Coherence factor (CF) can…
Quantitative magnetic resonance imaging (qMRI) allows images to be compared across sites and time points, which is particularly important for assessing long-term conditions or for longitudinal studies. The multiparametric mapping (MPM)…
Purpose: In multi-spectral imaging (MSI), several fast spin echo volumes with discrete Larmor frequency offsets are acquired in an interleaved fashion with multiple concatenations. Here, a variable resolution (VR) method to nearly halve…
In Photoacoustic imaging (PA), Delay-and-Sum (DAS) beamformer is a common beamforming algorithm having a simple implementation. However, it results in a poor resolution and high sidelobes. To address these challenges, a new algorithm namely…
Photoacoustic imaging (PAI) is a promising medical imaging modality providing the spatial resolution of ultrasound (US) imaging and the contrast of pure optical imaging. For linear-array PAI, a beamformer has to be used as the…
Remote sensing is a technology to acquire data for disatant substances, necessary to construct a model knowledge for applications as classification. Recently Hyperspectral Images (HSI) becomes a high technical tool that the main goal is to…