English
Related papers

Related papers: Separation of gamma-ray and neutron events with Cs…

200 papers

There are recent interests with CsI(Tl) scintillating crystals for Dark Matter experiments. The key merit is the capability to differentiate nuclear recoil (nr) signatures from the background $\beta / \gamma$-events due to ambient…

Data Analysis, Statistics and Probability · Physics 2009-11-10 S. C. Wu

Pulse shape discrimination with pure CsI scintillators is investigated as a method for separating energy deposits by energetic neutrons and photons at particle physics experiments. Using neutron data collected near the European XFEL XS1…

Instrumentation and Detectors · Physics 2022-07-11 S. Longo , M. Khan , S. Dharani , B. von Krosigk , T. Ferber

Scintillators have long been known as radiation detectors and are still used in various applications. Recently, scintillators containing $^6$Li have been developed as neutron detectors and have attracted attention. $^6$Li absorbs thermal…

Instrumentation and Detectors · Physics 2023-01-09 Takashi Iida , Masao Yoshino , Kei Kamada , Rei Sasaki , Ryuga Yajima

There are recent interests with CsI(Tl) scintillating crystals for Dark Matter experiments. The scattering signatures by neutrons on a CsI(Tl) detector were studied using a neutron beam generated by a 13 MV Tandem accelerator. The energy…

Nuclear Experiment · Physics 2011-07-19 M. Z. Wang

Scintillators capable of detecting both neutrons and gamma-rays have generated considerable interest. In particular, the use of such scintillators with silicon photomultipliers (SiPMs) enables low-power and compact-geometry applications.…

Instrumentation and Detectors · Physics 2018-08-29 Felix Liang , Hartmut Brands , Les Hoy , Jeff Preston , Jason Smith

We report a study of CsI(Tl) scintillator to assess its applicability in experiments to search for dark matter particles. Measurements of the mean scintillation pulse shapes due to nuclear and electron recoils have been performed. We find…

The basic principles of detection of fast neutrons with liquid scintillator detectors are reviewed, together with a real example in the form of the Neutron Wall array. Two of the challenges in neutron detection, discrimination of neutrons…

Nuclear Experiment · Physics 2008-12-08 P. -A. Söderström

Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z…

Instrumentation and Detectors · Physics 2022-12-14 Viacheslav A. Li , Felicia Sutanto , Timothy M. Classen , Steven A. Dazeley , Igor Jovanovic , Tingshiuan C. Wu

Fast-neutron/gamma-ray pulse-shape discrimination has been performed for the organic liquid scintillators NE 213A and EJ 305 using a time-of-flight based neutron-tagging technique and waveform digitization on an event-by-event basis.…

Pressurized Helium-4 (PHe) based fast neutron scintillation detector offers an useful alternative to organic liquid-based scintillator due to its relatively low response to the $\gamma$-rays compared to the latter type of scintillator. In…

Instrumentation and Detectors · Physics 2024-09-04 Shubham Dutta , Sayan Ghosh , Satyajit Saha

We constructed a neutron calibration facility based on a 300-mCi Am-Be source in conjunction with a search for weakly interacting massive particle candidates for dark matter. The facility is used to study the response of CsI(Tl) crystals to…

Novel NaIL detector (5x6 inch) was investigated for aims of neutron detection in wide energy range. It has been found that the detector together with its known ability to detect the {\gamma}- radiation is also allows to distinguish neutron…

Instrumentation and Detectors · Physics 2021-12-13 D. Ponomarev , D. Filosofov , J. Khushvaktov , A. Lubashevskiy , I. Rozova , S. Rozov , K. Shakhov , Yu. Shitov , V. Timkin , E. Yakushev , I. Zhitnikov

A series of test experiments on three different Si-based neutron detectors, namely a 1-d 128 channel, 0.5 mm space resolution Si microstrip sensor coupled to natural Gd converter, a medium size ? 1 cm2 PIN diode coupled to nGd2O3 or…

Instrumentation and Detectors · Physics 2018-05-04 G. Mauri , M. Mariotti , F. Casinini , F. Sacchetti , C. Petrillo

A monitoring system for fast neutrons is planned in the COSINE experiment, a dark matter experiment with NaI crystals. We pursued several R&D approaches for a neutron detector using a liquid scintillator (LS). A pulse shape discrimination…

Instrumentation and Detectors · Physics 2018-07-25 G. Adhikari , P. Adhikari , C. Ha , E. J. Jeon , K. W. Kim , N. Y. Kim , Y. D. Kim , Y. J. Ko , H. S. Lee , J. Lee , M. H. Lee , R. H. Maruyama , S. L. Olsen , H. Prihtiadi

We present a detailed characterization of the thermal neutron sensitive transparent glass scintillator SG101, benchmarked against the conventional LiF ZnS(Ag)based scintillator EJ426. The detection efficiency, energy resolution, and pulse…

Instrumentation and Detectors · Physics 2026-02-13 Yuhang Liu , Fengpeng An , Guang Luo , Wei Wang , Wei Wei , Xuesong Zhang , Dixiao Lu , Xiaohao Yin

Searches for weakly interacting massive particles(WIMP) can be based on the dete ction of nuclear recoil energy in CsI(Tl) crystals. We demonstrate that low energy gamma rays down to few keV is detected with CsI(Tl) crystal detector. A…

Instrumentation and Detectors · Physics 2019-08-17 H. J. Kim , H. J. Ahn , S. K. Kim , E. Won , T. Y. Kim , Y. D. Kim , M. H. Lee , J. S. Chai , J. H. Ha

Discrimination of the detection of fast neutrons and gamma rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator…

Nuclear Experiment · Physics 2008-12-08 P. -A. Söderström , J. Nyberg , R. Wolters

Radionuclide Identification Devices (RIDs) or Backpack Radiation Detection Systems (BRDs) are often equipped with NaI(Tl) detectors. We demonstrate that such instruments could be provided with reasonable thermal- and fast-neutron…

Instrumentation and Detectors · Physics 2022-08-16 Guntram Pausch , Achim Kreuels , Falko Scherwinski , Yong Kong , Mathias Kuester , Ralf Lentering , Andreas Wolf , Juergen Stein

It is very important to measure the plasma performances of fusion reactors such as fuel ion density, plasma temperature, fusion power, fast neutron energy, and neutron flux. Various diagnostic systems are needed to measure fast neutron…

Nuclear Experiment · Physics 2024-07-10 Iskender Atilla Reyhancan

Various pulse shape discrimination methods have been used to solve the neutron-gamma discrimination problem. But most of them are limited to off-line calculation due to the computation amount and FPGA performance. In order to realize real…

Instrumentation and Detectors · Physics 2022-01-26 Haoqi Ye , Ge Jin , Lian Chen
‹ Prev 1 2 3 10 Next ›