Related papers: Study of a Prototype VP-PET Imaging System Based o…
The fastCAT application uses pre-calculated Monte Carlo (MC) CBCT phantom-specific scatter and detector response functions to reduce simulation time for megavoltage (MV) and kilovoltage (kV) CBCT imaging. Pre-calculated x-ray beam energy…
Muon Tomography (MT) based on the measurement of multiple scattering of atmospheric cosmic ray muons traversing shipping containers is a promising candidate for identifying threatening high-Z materials. Since position-sensitive detectors…
A mini-PET style detector system is being developed for a plant imaging application with a compact array of silicon photomultipliers (SiPM) replacing position sensitive photomultipliers (PSPMT). In addition to compactness, the use of SiPMs…
We report measurement of the valence-to-core (VTC) region of the K-shell x-ray emission spectra from several Zn and Fe inorganic compounds, and their critical comparison with several existing theoretical treatments. We find generally good…
Recent Transformer-based 3D object detectors learn point cloud features either from point- or voxel-based representations. However, the former requires time-consuming sampling while the latter introduces quantization errors. In this paper,…
Positron emission tomographs (PET) do not measure an image directly. Instead, they measure at the boundary of the field-of-view (FOV) of PET tomograph a sinogram that consists of measurements of the sums of all the counts along the lines…
Many spintronic, magnetic-memory, and neuromorphic devices rely on spatially varying magnetic fields. Quantitatively imaging these fields with full vector information over extended areas remains a major challenge. Existing probes either…
Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) combined with Computed Tomography (CT) scans are critical in oncology to the identification of solid tumours and the monitoring of their progression. However, precise and consistent…
We developed a beam telescope system comprising five layers of 300-$\mu$m-thick INTPIX4NA monolithic pixel sensors with each pixel size of 17 $\mu$m square. The sensors were fabricated using silicon-on-insulator (SOI) technology. The…
In this paper, we provide a novel method for the estimation of unknown parameters of the Gaussian Mixture Model (GMM) in Positron Emission Tomography (PET). A vast majority of PET imaging methods are based on reconstruction model that is…
Due to the widespread use of positron emission tomography (PET) in clinical practice, the potential risk of PET-associated radiation dose to patients needs to be minimized. However, with the reduction in the radiation dose, the resultant…
We present a versatile analytic model describing Photon Detection Efficiency (PDE) for P-on-N silicon photomultipliers, with possible applications for device characterization, PDE extrapolation from limited data, simulation and design…
We present the design and initial prototype results of a pixellized proton beam profile monitor for the COMET experiment at J-PARC. The goal of COMET is to look for charged lepton flavor violation by direct muon to electron conversion at a…
This work reports on the performance of a novel neutron-sensitive scintillating detector fabricated using Fused-Deposition Modelling (FDM) additive manufacturing. FDM is a cost-effective 3D-printing method employing flexible plastic…
The detectors based on the liquid scintillator (LS) monitored by an array of photo-multiplier tubes (PMT) are often used in low energy experiments such as neutrino oscillation studies and search for dark matter. Detectors of this kind…
Proton Computed Tomography (CT) is a prototype imaging modality for the reconstruction of the Relative Stopping Power of a patient, for more accurate calculations of the dose distributions in proton therapy dose planning. The measurements…
A major strength of iterative algorithms used in positron emission tomography (PET) lies in their abilities to introduce precise models of the physics at play, which includes the statistical nature of the detection processes, and a detailed…
We report the fabrication and performance of an annular, cryogenic, phonon-mediated veto detector that can host an inner target detector, allowing substantial reduction in radiogenic backgrounds for rare event search experiments. A…
Tau positron emission tomography (tau-PET) is an important in vivo biomarker of Alzheimer's disease, but its cost, limited availability, and acquisition burden restrict broad clinical use. This work proposes an interpretable multimodal…
Pixelated CdZnTe detectors are a promising imaging-spectrometer for gamma-ray astrophysics due to their combination of relatively high energy resolution with room temperature operation negating the need for cryogenic cooling. This reduces…