Related papers: Quick X-ray microtomography using a laser-driven b…
We present an experimental demonstration of high conversion efficiency Betatron x-ray radiation from petawatt laser irradiated near critical plasmas. Direct laser acceleration serves as the dominant regime when laser pulse of ~5e20 W/cm2…
Bright sources of high energy electromagnetic radiation are widely employed in fundamental research as well as in industry and medicine. This steadily growing interest motivated the construction of several facilities aiming at the…
We present a simple apparatus for femtosecond laser induced generation of X-rays. The apparatus consists of a vacuum chamber containing an off-axis parabolic focusing mirror, a reel system, a debris protection setup, a quartz window for the…
Despite the increased brilliance of the new generation synchrotron sources, there is still a challenge with high-resolution scanning of very thick and absorbing samples, such as the whole mouse brain stained with heavy elements, and,…
We propose an imaging system and methodology for mapping soft-tissue samples in three dimensions, with micron-scale and isotropic spatial resolution, with low-concentrations as well as in the absence of heavy metal staining. We used hard…
A commercially-available titanium-sapphire laser system has recently been installed at the Fermilab A0 photoinjector laboratory in support of photoemission and electron beam diagnostics studies. The laser system is synchronized to both the…
The intrinsic constraints in the amplitude of the accelerating fields sustainable by radio-frequency accelerators demand for the pursuit of alternative and more compact acceleration schemes. Among these, plasma-based accelerators are…
Femtosecond transient soft X-ray Absorption Spectroscopy (XAS) is a very promising technique that can be employed at X-ray Free Electron Lasers (FELs) to investigate out-of-equilibrium dynamics for material and energy research. Here we…
The number of photons available by coherent X-ray scattering from a single biomolecule is considerably less because of the extremely small elastic-scattering cross-section and low damage threshold. Even with a high X-ray flux of 3 x 10to 12…
In the last years, optical readout of Micromegas gaseous detectors has been achieved by implementing a Micromegas detector on a glass anode coupled to a CMOS camera. Effective X-ray radiography was demonstrated using integrated imaging…
The penetration power of x-rays allows one to image large objects. For example, centimeter-sized specimens can be imaged with micron-level resolution using synchrotron sources. In this case, however, the limited beam diameter and detector…
A novel type of pulsed X-ray generator especially suitable for rare event searches, as dark matter and neutrino experiments, has been developed. Being compact and built with selected radio-pure materials, it is appropriate for…
The continuing improvement in quantum efficiency (above 90% for single visible photons), reduction in noise (below 1 electron per pixel), and shrink in pixel pitch (less than 1 micron) motivate billion-pixel X-ray cameras (BiPC-X) based on…
The design and optimization of laser-Compton x-ray systems based on compact distributed charge accelerator structures can enable micron-scale imaging of disease and the concomitant production of beams of Very High Energy Electrons (VHEEs)…
In the cavitation regime of plasma-based accelerators, a population of high-energy electrons tailing the driver can undergo betatron motion. The motion results in X-ray emission, but the brilliance and photon energy are limited by the…
Synchrotron radiation has been used for many years as a beam diagnostic at electron accelerators. It is not normally associated with proton accelerators as the intensity of the radiation is too weak to make detection practical. However, if…
We present an end-to-end automated workflow that uses large-scale remote compute resources and an embedded GPU platform at the edge to enable AI/ML-accelerated real-time analysis of data collected for x-ray ptychography. Ptychography is a…
We model the absorption of X-rays by gas obscuring the source and photoionized by it. We consider a broad range of column densities, including both Thomson-thin and Thomson-thick media. For the Thomson thin regime, we derive a simple…
Cone beam computed tomography (CBCT) for breast imaging has potential to replace conventional mammograms. However, concerns over dose and image quality prevent CBBCT systems from the clinical trial phase to next stage. The time of flight…
The transmission X-ray microscope (TXM) on the Anatomix beamline welcomed its first nano-tomography users in 2019. The instrument is based on diffractive optics and works in the range of energies from 7 keV to 21 keV. A spatial resolution…