Related papers: Ultra-Fast Hadronic Calorimetry
We study the longitudinal development of hadronic showers in water and ice for energies up to 100 EeV. We present results of a hybrid Monte Carlo method developed for the purpose of simulating those showers. We show parameterizations of the…
Simulations of particle showers in calorimeters are computationally time-consuming, as they have to reproduce both energy depositions and their considerable fluctuations. A new approach to ultra-fast simulations are generative models where…
The CASTOR calorimeter is a detector covering the very forward region of the CMS experiment at the LHC. It surrounds the beam pipe with 14 longitudinal modules each of which consisting of 16 azimuthal sectors and allows to reconstruct…
A prototype of a dual-readout calorimeter using brass capillary tubes surrounding scintillating and clear plastic optical fibres was tested using beams of particles with energies between 10 and 100 GeV produced by the CERN SPS. The scope of…
Application of Micromegas for sampling calorimetry puts specific constraints on the design and performance of this gaseous detector. In particular, uniform and linear response, low noise and stability against high ionisation density…
This article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section…
In 2002 the first combined beam test of the hadronic and electromagnetic liquid-argon endcap calorimeters of the ATLAS experiment took place at the SPS test beam at CERN. A total of 15 million events from electrons, muons and pions in the…
We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic…
The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two…
Ultrahigh energy cosmic ray air showers probe particle physics at energies beyond the reach of accelerators. Here we introduce a new method to test hadronic interaction models without relying on the absolute energy calibration, and apply it…
After the construction and successful operation of the first technological prototype of the Semi-Digital Hadronic CALorimeter (SDHCAL), developed within the CALICE collaboration, new R{\&}D efforts have been initiated to fully validate the…
The CALICE collaboration has constructed a hadronic sandwich calorimeter prototype with 7608 scintillating plates, individually read out by multi-pixel silicon photomultipliers (SiPMs). For the first time ever the read out is performed…
To achieve the physics goal of precisely measure the Higgs, Z, W bosons and the top quark, future electron-positron colliders require that their detector system has excellent jet energy resolution. One feasible technical option is the high…
The software compensation algorithms developed for the CALICE Analog Hadron Calorimeter are extended to incorporate time information on the cell level, and the performance is studied in GEANT4 simulations with a detector model of a…
Physicists at the Large Hadron Collider (LHC) rely on detailed simulations of particle collisions to build expectations of what experimental data may look like under different theory modeling assumptions. Petabytes of simulated data are…
An important experiment for cosmic ray physics is going to be conducted with the colliding proton beams of the CERN LHC. The equivalent energy of the 14 TeV center of mass energy of the colliding proton beams in the LHC is 1017eV in the…
Calorimeters are a crucial component in modern particle detectors. They are responsible for providing accurate energy measurements of particles produced in high-energy collisions. The demanding requirements set for next-generation collider…
A first prototype of a scintillator strip-based electromagnetic calorimeter was built, consisting of 26 layers of tungsten absorber plates interleaved with planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a…
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are…
A compact and fast electromagnetic calorimeter prototype was designed, built, and tested in preparation for a next-generation, high-rate muon g-2 experiment. It uses a simple assembly procedure: alternating layers of 0.5-mm-thick tungsten…