Related papers: Ultimate position resolution of pixel clusters wit…
We have operated a Medipix2 CMOS readout chip, with amplifying, shaping and charge discriminating front-end electronics integrated on the pixel-level, as a highly segmented direct charge collecting anode in a three-stage gas electron…
First measurements are presented from a newly commissioned two-photon absorption (TPA) setup at Nikhef. The characterisation of the various components of the system is discussed. Two planar silicon sensors, one being electron collecting and…
A simple, analytically correct algorithm is developed for calculating pencil beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The…
An extensive comparison of the path uncertainty in single particle tracking systems for ion imaging was carried out based on Monte Carlo simulations. The spatial resolution as function of system parameters such as geometry, detector…
In typical nuclear physics experiments with radioactive ion beams (RIBs) selected by the in-flight separation technique, Si detectors or ionization chambers are usually equipped for the charge determination of RIBs. The obtained charge…
The skipper CCD is a special type of charge coupled device in which the readout noise can be reduced to sub-electron levels by averaging independent measurements of the same charge. Thus the charge in the pixels can be determined by…
CMOS Pixel Sensors tend to become relevant for a growing spectrum of charged particle detection instruments. This comes mainly from their high granularity and low material budget. However, several potential applications require a higher…
Silicon tracking detectors provide excellent spatial resolution, and so can provide excellent momentum resolution for energetic charged particles, even in compact detectors. However, at lower momenta, multiple scattering in the silicon…
We show that doubly peaked electric fields are necessary to describe grazing-angle charge collection measurements of irradiated silicon pixel sensors. A model of irradiated silicon based upon two defect levels with opposite charge states…
Good geometrical calibration is essential in the use of high resolution detectors. The individual sensors in the detector have to be calibrated with an accuracy better than the intrinsic resolution, which typically is of the order of 10 um.…
A large volume TPC is a leading candidate for the central tracking detector at a future high energy linear collider. To improve the resolution a new readout based on micro-pattern gas detectors is being developed. Measurements of the…
Investigation of HV-CMOS sensors for use as a tracking detector in the ATLAS experiment at the upgraded LHC (HL-LHC) has recently been an active field of research. A potential candidate for a pixel detector built in Silicon-On-Insulator…
Silicon detectors have gained in popularity since silicon became a widely used micro/nanoelectronic semiconductor material. Silicon detectors are used in particle physics as well as imaging for pixel based detecting systems. Over the past…
A silicon pixel detector with fine pitch size of 19x19 um, developed base on SOI (silicon on insulator) technology, was tested under the illumination of infrared laser pulses. As an alternative way to particle beam tests, the laser pulses…
Timepix3 pixel detectors have demonstrated great potential for tracking applications. With $256\times 256$ pixels, 55 $\mathrm{\mu}$m pitch and improved resolution in time (1.56 ns) and energy (2 keV at 60 keV), they have become powerful…
Beam position monitors (BPMs) are indispensable components of modern particle accelerators, providing real-time diagnostics to ensure precise beam control, stability, and quality. As accelerators such as the International Linear Collider…
In order to cope with increasing lifetime radiation damage expected at collider experiments, silicon sensors are becoming increasingly thin. To achieve adequate detection efficiency, the next generation of detectors may have to operate with…
We have been developing X-ray SOIPIXs for next-generation satellites for X-ray astronomy. Their high time resolution ($\sim10~\mu$s) and event-trigger-output function enable us to read out without pile-ups and to use anti-coincidence…
Low-energy electron recoils are of interest in several planned and proposed future nuclear and particle physics experiments. The topology and directions of such recoils provide important particle identification and kinematical constraints,…
To enhance the spatial resolution of the M\"ONCH 25 \textmu m pitch hybrid pixel detector, deep learning models have been trained using both simulation and measurement data. Challenges arise when comparing simulation-based deep learning…